It is designed to endure severe heat, making it ideal for applications where normal wires would decay or fail.
Type: MGT wire
Core: nickel-coated copper (27%)(other conductor materials available)
Insulation: mica tape
Reinforcing braid: varnished fiberglass braid with high-temperature finish
Range width: AWG 24 to 4
Options: please consult us for any special requirements
Household appliances: cabling for domestic electrical heating appliances: kitchens, professional ovens, etc.
Heating elements: cabling for heating resistors, cartridges, bands and plates
Other(s): cabling for furnaces, ovens, machines for thermoplastics and rubber, welding stations, etc.
Operating environment: good resistance to thermal shock
Chemical behavior: good resistance to oxidization
Operating temperature: -60°C to +550°C
Operating Voltage: 600V
“FT1 flame rating”: as per UL approval