FHLR2X
FHLR2X is a CASMO high-voltage cable for EV High Voltage. XLPE insulated, 125°C, 600/900V. FHLR2X automotive cable per ISO 19642-5, rated 125°C and 600V AC / 900V DC.
FHLR2X automotive cable per ISO 19642-5, rated 125°C and 600V AC / 900V DC.
Key Ratings
- FHLR2X: · Temperature 125°C · Rated Voltage 600/900V
Construction
- Conductor
- Flexible Bare Copper or Flexible Tinned Copper
- Insulation
- Extruded · XLPE
Characteristics
- Ultra-Thin Wall: Ultra-thin insulation keeps the finished cable small for dense, lightweight harnesses.
- Heat Stability: Holds its dimensions after heat exposure, with minimal shrinkage at the cable ends.
Applications
- Automotive High-Voltage Circuits: Ultra-thin-wall, heat-resistant primary wiring for high-voltage automotive circuits.
Standards & Compliance
- Standard: ISO 19642-5
- RoHS: Compliant
- REACH: Compliant
FHLR2X-A
| CASMO Part No. | Conductor Size (mm²) | No. Of Strands | Max. Strand Dia. (mm) | Max. Conductor Dia. (mm) | Min. Ins. Thickness (mm) | Max. Overall O.D. (mm) | Max. DCR BC @20°C (Ω/km) | Max. DCR TPC @20°C (Ω/km) | Nom. Cable Weight (kg/km) |
|---|---|---|---|---|---|---|---|---|---|
| 1150040.35/7-**-XX | 0.35 | 7 | 0.26 | 0.80 | 0.20 | 1.30 | 54.4 | 55.5 | 4.8 |
| 1150040.5/19-**-XX | 0.5 | 19 | 0.19 | 1.00 | 0.22 | 1.60 | 37.1 | 38.2 | 6.7 |
| 1150040.75/19-**-XX | 0.75 | 19 | 0.24 | 1.20 | 0.24 | 1.90 | 24.7 | 25.4 | 9.4 |
| 1150041/19-**-XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.10 | 18.5 | 19.1 | 11.9 |
| 1150041.5/19-**-XX | 1.5 | 19 | 0.32 | 1.70 | 0.24 | 2.40 | 12.7 | 13 | 17.0 |
| 1150042.5/19-**-XX | 2.5 | 19 | 0.41 | 2.20 | 0.28 | 3.00 | 7.6 | 7.82 | 27.5 |
† Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. ‡ Replace ** with the conductor code: AS for bare copper or TS for tinned copper.
- Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
- Replace ** with the conductor code: AS for bare copper or TS for tinned copper.
FHLR2X-B
| CASMO Part No. | Conductor Size (mm²) | No. Of Strands | Max. Strand Dia. (mm) | Max. Conductor Dia. (mm) | Min. Ins. Thickness (mm) | Max. Overall O.D. (mm) | Max. DCR BC @20°C (Ω/km) | Max. DCR TPC @20°C (Ω/km) | Nom. Cable Weight (kg/km) |
|---|---|---|---|---|---|---|---|---|---|
| 1150040.35/12-**-XX | 0.35 | 12 | 0.21 | 0.90 | 0.20 | 1.40 | 54.4 | 55.5 | 4.8 |
| 1150040.5/16-**-XX | 0.5 | 16 | 0.21 | 1.00 | 0.22 | 1.60 | 37.1 | 38.2 | 6.7 |
| 1150040.75/24-**-XX | 0.75 | 24 | 0.21 | 1.20 | 0.24 | 1.90 | 24.7 | 25.4 | 9.3 |
| 1150041/32-**-XX | 1 | 32 | 0.21 | 1.35 | 0.24 | 2.10 | 18.5 | 19.1 | 11.8 |
| 1150041.5/30-**-XX | 1.5 | 30 | 0.26 | 1.70 | 0.24 | 2.40 | 12.7 | 13 | 16.8 |
| 1150042/28-**-XX | 2 | 28 | 0.31 | 2.00 | 0.28 | 2.80 | 9.42 | 9.69 | 21.4 |
| 1150042.5/50-**-XX | 2.5 | 50 | 0.26 | 2.20 | 0.28 | 3.00 | 7.6 | 7.82 | 28.0 |
† Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. ‡ Replace ** with the conductor code: AS for bare copper or TS for tinned copper.
- Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
- Replace ** with the conductor code: AS for bare copper or TS for tinned copper.