ISO 19642 — International Road-Vehicle Low- & High-Voltage Cables
Multi-part global automotive standard superseding ISO 6722 and ISO 14572 — governing single-core LV primary wires (Parts 3 and 4) and unscreened or screened EV high-voltage cables (Parts 5, 6, 9 and 10) across temperature classes A through F.
Standard · International Organization for Standardization (ISO)
What is ISO 19642?
ISO 19642 is the unified international standard for road-vehicle electrical cables, superseding legacy ISO 6722 (single-core cables) and ISO 14572 (round multi-core cables). Organised into ten parts, it harmonises metric conductor geometries, standard/thin/ultra-thin wall classes, outer diameter tolerances, test methods (Part 2) and temperature classes from Class A (85°C) to Class F (200°C) for global connector compatibility.
Low-voltage single-core harnesses are governed by Part 3 (copper conductors, 60V DC / 25V AC — spanning European designations such as FLRY, FLR2X, FLR9Y, FLR13Y, FL2G, FLR2G and CIVUS) and Part 4 (aluminium conductors), while electrified powertrains use Parts 5 and 6 for unscreened copper and aluminium high-voltage cables and Parts 9 and 10 for screened and sheathed high-voltage constructions rated up to 1000V AC / 1500V DC.
Key Technical Requirements
| Parameter | Requirement | Notes |
|---|---|---|
| LV parts (60V DC) | Parts 3 & 4 | Single-core copper & aluminium (replaces ISO 6722) |
| HV parts (≤1500V DC) | Parts 5, 6, 9 & 10 | Unscreened Cu/Al & screened/sheathed EV HV cables |
| Temperature classes | Class A (85°C) to Class F (200°C) | Class B 105°C, C 125°C, D 150°C, E 175°C |
| Test methods | ISO 19642-2 / ISO 6722-1 | Flame, abrasion, thermal ageing, fluids & HV |
ISO 19642 Products
- FLYW125 — ISO 19642-3 · Heat-Resistant PVC · 125°C · 25/60V
- FLYKW — ISO 19642-3 · PVC · 105°C · 25/60V
- FLY — ISO 19642-3 · PVC · 85°C · 25/60V
- FLUY — ISO 19642-3 · PVC · 105°C · 25/60V
- FLU6Y — ISO 19642-3 · FEP · 200°C · 25/60V
- FLRYW125 — ISO 19642-3 · Heat-Resistant PVC · 125°C · 25/60V
- FLRY — ISO 19642-3 · PVC · 105°C · 25/60V
- FLRX — ISO 19642-3 · XLPVC · 105°C · 25/60V
- FLR91X — ISO 19642-3 · XLPO · 125°C · 25/60V
- FLR51Y — ISO 19642-3 · PFA · -40°C to +260°C · 25/60V
- FLR31Y — ISO 19642-3 · TPE-S · 125°C · 25/60V
- FLR13Y — ISO 19642-3 · TPE-E (Hydrolysis-Resistant) · 150°C · 25/60V
- FLR12Y — ISO 19642-3 · TPE-E · 150°C · 25/60V
- FLR9Y — ISO 19642-3 · PP · 125°C · 25/60V
- FLR7Y — ISO 19642-3 · ETFE · -40°C to +180°C · 25/60V
- FLR6Y — ISO 19642-3 · FEP · -40°C to +200°C · 25/60V
- FLR5Y — ISO 19642-3 · PTFE · -40°C to +260°C · 25/60V
- FLR4Y — ISO 19642-3 · PA (Polyamide) · 100°C · 25/60V
- FLR2X150 — ISO 19642-3 · XLPE · 150°C · 25/60V
- FLR2X — ISO 19642-3 · XLPE · 125°C · 25/60V
- FLR2G — ISO 19642-3 · Silicone Rubber (SiR) · -40°C to +200°C · 25/60V
- FL9Y — ISO 19642-3 · PP · 125°C · 25/60V
- FL2G — ISO 19642-3 · Silicone Rubber (SiR) · -40°C to +200°C · 25/60V
- FHLRY — ISO 19642-5 · PVC · 105°C · 600/900V
- FHLR91XCB91X — ISO 19642-9 · XLPO · -40°C to +150°C · 1000/1500V
- FHLR91XC91X — ISO 19642-9 · XLPO · -40°C to +150°C · 1000/1500V
- FHLR13Y — ISO 19642-5 · TPE-E (Hydrolysis-Resistant) · 150°C · 600/900V
- FHLR12Y — ISO 19642-5 · TPE-E · 150°C · 600/900V
- FHLR9Y — ISO 19642-5 · PP · 125°C · 600/900V
- FHLR2X — ISO 19642-5 · XLPE · 125°C · 600/900V
- FHLR2GCB91X — ISO 19642-9 · Silicone Rubber (SiR) · -40°C to +150°C · 1000/1500V
- FHLR2GCB2G MC — ISO 19642-9 · Silicone Rubber (SiR) · -40°C to +180°C · 1000/1500V
- FHLR2GCB2G — ISO 19642-9 · Silicone Rubber (SiR) · -40°C to +180°C · 1000/1500V
- FHLR2GC91X — ISO 19642-9 · Silicone Rubber (SiR) · -40°C to +150°C · 1000/1500V
- FHLR2GC2G — ISO 19642-9 · Silicone Rubber (SiR) · -40°C to +180°C · 1000/1500V
- FHLR2G2G MC — ISO 19642-9 · Silicone Rubber (SiR) · -40°C to +180°C · 1000/1500V
- FHLR2G — ISO 19642-5 · Silicone Rubber (SiR) · -40°C to +180°C · 1000/1500V
- FHL9Y — ISO 19642-5 · PP (Polypropylene) · -40°C to +125°C · 1000/1500V
- FHL2X — ISO 19642-5 · XLPE · -40°C to +150°C · 1000/1500V
- FHL2G — ISO 19642-5 · Silicone Rubber (SiR) · -40°C to +200°C · 1000/1500V
- CIVUS — ISO 19642-3 · PVC · 105°C · 25/60V
Insulation Materials in This Standard
Frequently Asked Questions
- How does ISO 19642 relate to ISO 6722?
- ISO 19642 superseded and consolidated ISO 6722 and ISO 14572 into one modern multi-part standard family. Legacy drawings may still cite ISO 6722-1 test methods alongside ISO 19642-2.
- Does meeting ISO 19642-5 or -9 automatically qualify a cable to German OEM LV 216?
- No. While ISO 19642 and LV 216 share closely aligned cable families and voltage ratings, LV 216 is a separate German OEM specification with additional OEM-specific validation schedules; project-specific testing can be arranged upon request.
- Which automotive wire families does CASMO build to ISO 19642?
- CASMO manufactures a comprehensive line of ISO 19642-3 low-voltage primary wires (including FLRY, FLR2X, FLR9Y, FLR12Y, FLR13Y, FL2G, FLR2G and CIVUS families) alongside ISO 19642-5/-9 EV high-voltage cables (including FHL2G, FHL2X, FHLR2X, FHLR9Y, FHLR12Y, FHLR13Y, FHLRY and FHLR2GCB2G).
Engineering Guides
- XLPE Cross-Linking Methods Compared: Electron-Beam Irradiation vs. Chemical Peroxide (CCV) vs. Silane (Sioplas & Monosil) — How electron-beam irradiation, chemical peroxide CCV curing, and silane moisture cross-linking convert polyethylene into thermoset XLPE — comparing thermal rating, wall-thickness limits, scorch risk, hot-set QC testing, and XLPE/XLPO/XLPVC/XL-ETFE wire standards.