ISO 19642 — International Road-Vehicle Low- & High-Voltage Cables

Multi-part global automotive standard superseding ISO 6722 and ISO 14572 — governing single-core LV primary wires (Parts 3 and 4) and unscreened or screened EV high-voltage cables (Parts 5, 6, 9 and 10) across temperature classes A through F.

Standard · International Organization for Standardization (ISO)

What is ISO 19642?

ISO 19642 is the unified international standard for road-vehicle electrical cables, superseding legacy ISO 6722 (single-core cables) and ISO 14572 (round multi-core cables). Organised into ten parts, it harmonises metric conductor geometries, standard/thin/ultra-thin wall classes, outer diameter tolerances, test methods (Part 2) and temperature classes from Class A (85°C) to Class F (200°C) for global connector compatibility.

Low-voltage single-core harnesses are governed by Part 3 (copper conductors, 60V DC / 25V AC — spanning European designations such as FLRY, FLR2X, FLR9Y, FLR13Y, FL2G, FLR2G and CIVUS) and Part 4 (aluminium conductors), while electrified powertrains use Parts 5 and 6 for unscreened copper and aluminium high-voltage cables and Parts 9 and 10 for screened and sheathed high-voltage constructions rated up to 1000V AC / 1500V DC.

Key Technical Requirements

ParameterRequirementNotes
LV parts (60V DC)Parts 3 & 4Single-core copper & aluminium (replaces ISO 6722)
HV parts (≤1500V DC)Parts 5, 6, 9 & 10Unscreened Cu/Al & screened/sheathed EV HV cables
Temperature classesClass A (85°C) to Class F (200°C)Class B 105°C, C 125°C, D 150°C, E 175°C
Test methodsISO 19642-2 / ISO 6722-1Flame, abrasion, thermal ageing, fluids & HV

ISO 19642 Products

  • FLYW125 — ISO 19642-3 · Heat-Resistant PVC · 125°C · 25/60V
  • FLYKW — ISO 19642-3 · PVC · 105°C · 25/60V
  • FLY — ISO 19642-3 · PVC · 85°C · 25/60V
  • FLUY — ISO 19642-3 · PVC · 105°C · 25/60V
  • FLU6Y — ISO 19642-3 · FEP · 200°C · 25/60V
  • FLRYW125 — ISO 19642-3 · Heat-Resistant PVC · 125°C · 25/60V
  • FLRY — ISO 19642-3 · PVC · 105°C · 25/60V
  • FLRX — ISO 19642-3 · XLPVC · 105°C · 25/60V
  • FLR91X — ISO 19642-3 · XLPO · 125°C · 25/60V
  • FLR51Y — ISO 19642-3 · PFA · -40°C to +260°C · 25/60V
  • FLR31Y — ISO 19642-3 · TPE-S · 125°C · 25/60V
  • FLR13Y — ISO 19642-3 · TPE-E (Hydrolysis-Resistant) · 150°C · 25/60V
  • FLR12Y — ISO 19642-3 · TPE-E · 150°C · 25/60V
  • FLR9Y — ISO 19642-3 · PP · 125°C · 25/60V
  • FLR7Y — ISO 19642-3 · ETFE · -40°C to +180°C · 25/60V
  • FLR6Y — ISO 19642-3 · FEP · -40°C to +200°C · 25/60V
  • FLR5Y — ISO 19642-3 · PTFE · -40°C to +260°C · 25/60V
  • FLR4Y — ISO 19642-3 · PA (Polyamide) · 100°C · 25/60V
  • FLR2X150 — ISO 19642-3 · XLPE · 150°C · 25/60V
  • FLR2X — ISO 19642-3 · XLPE · 125°C · 25/60V
  • FLR2G — ISO 19642-3 · Silicone Rubber (SiR) · -40°C to +200°C · 25/60V
  • FL9Y — ISO 19642-3 · PP · 125°C · 25/60V
  • FL2G — ISO 19642-3 · Silicone Rubber (SiR) · -40°C to +200°C · 25/60V
  • FHLRY — ISO 19642-5 · PVC · 105°C · 600/900V
  • FHLR91XCB91X — ISO 19642-9 · XLPO · -40°C to +150°C · 1000/1500V
  • FHLR91XC91X — ISO 19642-9 · XLPO · -40°C to +150°C · 1000/1500V
  • FHLR13Y — ISO 19642-5 · TPE-E (Hydrolysis-Resistant) · 150°C · 600/900V
  • FHLR12Y — ISO 19642-5 · TPE-E · 150°C · 600/900V
  • FHLR9Y — ISO 19642-5 · PP · 125°C · 600/900V
  • FHLR2X — ISO 19642-5 · XLPE · 125°C · 600/900V
  • FHLR2GCB91X — ISO 19642-9 · Silicone Rubber (SiR) · -40°C to +150°C · 1000/1500V
  • FHLR2GCB2G MC — ISO 19642-9 · Silicone Rubber (SiR) · -40°C to +180°C · 1000/1500V
  • FHLR2GCB2G — ISO 19642-9 · Silicone Rubber (SiR) · -40°C to +180°C · 1000/1500V
  • FHLR2GC91X — ISO 19642-9 · Silicone Rubber (SiR) · -40°C to +150°C · 1000/1500V
  • FHLR2GC2G — ISO 19642-9 · Silicone Rubber (SiR) · -40°C to +180°C · 1000/1500V
  • FHLR2G2G MC — ISO 19642-9 · Silicone Rubber (SiR) · -40°C to +180°C · 1000/1500V
  • FHLR2G — ISO 19642-5 · Silicone Rubber (SiR) · -40°C to +180°C · 1000/1500V
  • FHL9Y — ISO 19642-5 · PP (Polypropylene) · -40°C to +125°C · 1000/1500V
  • FHL2X — ISO 19642-5 · XLPE · -40°C to +150°C · 1000/1500V
  • FHL2G — ISO 19642-5 · Silicone Rubber (SiR) · -40°C to +200°C · 1000/1500V
  • CIVUS — ISO 19642-3 · PVC · 105°C · 25/60V

Insulation Materials in This Standard

Frequently Asked Questions

How does ISO 19642 relate to ISO 6722?
ISO 19642 superseded and consolidated ISO 6722 and ISO 14572 into one modern multi-part standard family. Legacy drawings may still cite ISO 6722-1 test methods alongside ISO 19642-2.
Does meeting ISO 19642-5 or -9 automatically qualify a cable to German OEM LV 216?
No. While ISO 19642 and LV 216 share closely aligned cable families and voltage ratings, LV 216 is a separate German OEM specification with additional OEM-specific validation schedules; project-specific testing can be arranged upon request.
Which automotive wire families does CASMO build to ISO 19642?
CASMO manufactures a comprehensive line of ISO 19642-3 low-voltage primary wires (including FLRY, FLR2X, FLR9Y, FLR12Y, FLR13Y, FL2G, FLR2G and CIVUS families) alongside ISO 19642-5/-9 EV high-voltage cables (including FHL2G, FHL2X, FHLR2X, FHLR9Y, FHLR12Y, FHLR13Y, FHLRY and FHLR2GCB2G).

Engineering Guides