FEP — Fluorinated Ethylene Propylene Insulation

Melt-processable fluoropolymer combining PTFE-like chemical immunity and 200°C continuous thermal endurance with smoother extrusion, greater flexibility and long continuous lengths.

What is FEP insulation?

Fluorinated ethylene propylene (FEP) is a melt-extrudable fluoropolymer closely related to PTFE. Because FEP melts during extrusion, it produces smooth, pinhole-free insulation walls in long continuous reel lengths with greater flexibility than sintered PTFE while retaining nearly identical chemical inertness, low dielectric loss and 200°C continuous thermal endurance.

FEP is widely specified across high-temperature UL AWM hook-up wires, NEMA HP4 equipment wires, aerospace harnesses, plenum/data cabling and moisture-sealed thermocouple extension cables where chemical resistance, low smoke and clean stripping are essential.

Electrically, FEP matches PTFE's ultra-low dielectric constant (εr 2.0–2.1) and inherent UL 94 V-0 / VW-1 flame retardance while extruding smoothly as both primary core insulation and moisture-tight multi-core outer jackets — spanning UL 1330/1332 hook-up styles, NEMA HP4, plenum constructions and chemical-resistant sensor cables. For full +200°C continuous ratings, pair FEP with silver-plated copper (ASTM B298) or nickel-plated copper rather than tinned copper above 150°C–180°C.

Critical multi-core design rule: never specify an electron-beam cross-linked outer jacket (such as irradiated XLPE, LSZH XLPO or cross-linked PUR/rubber) or a high-temperature peroxide CCV jacket over FEP primary cores. Electron-beam irradiation causes irreversible C–C chain scission and brittle cracking in FEP, while 280°C–400°C vulcanisation tubes exceed FEP's ~260°C melt point; instead pair FEP cores with non-cross-linked thermoplastic jackets such as FEP, ETFE, TPU/PUR, TPE or PVC.

Key Material Properties

PropertyRatingNotes
Max temperature200°C continuousFluoropolymer thermal class
TypeMelt-processable fluoropolymerLong continuous extruded lengths
Chemical resistanceExcellentBroad solvent, fuel & acid resistance
Typical usesNEMA HP4, high-temp AWM, aerospace, sensorsFlexible 200°C fluoropolymer routing
Dielectric & Meltεr ~2.0–2.1 · Melt ~260°CInherent UL 94 V-0 / VW-1; low-loss signal
Jacket compatibilityThermoplastic jackets onlyHard No on E-beam irradiation or CCV peroxide cure

FEP Insulated Products

  • UL 1887 — UL 758 AWM · FEP · -60°C to +150°C · 600V
  • UL 1333 — UL 758 AWM · FEP · -60°C to +150°C · 300V
  • UL 1332 — UL 758 AWM · FEP · -60°C to +200°C · 300V
  • UL 1331 — UL 758 AWM · FEP · -60°C to +150°C · 600V
  • UL 1330 — UL 758 AWM · FEP · -60°C to +200°C · 600V
  • SAE J1939/15-150 — SAE J1939/15 · Foam FEP · -40°C to +150°C · 300V
  • SAE J1939/11-150 — SAE J1939/11 · Foam FEP · -40°C to +150°C · 300V
  • NEMA HP 4 TYPE KT — NEMA HP4 · FEP · -65°C to +200°C · 250V
  • NEMA HP 4 TYPE KK — NEMA HP4 · FEP · -65°C to +200°C · 1000V
  • NEMA HP 4 TYPE K — NEMA HP4 · FEP · -65°C to +200°C · 600V
  • FLU6Y — ISO 19642-3 · FEP · 200°C · 25/60V
  • FLR6Y — ISO 19642-3 · FEP · -40°C to +200°C · 25/60V

Applications & Standards Using This Material

Frequently Asked Questions

What is the difference between FEP and PTFE?
Both share similar chemical resistance and dielectric properties, but FEP is melt-extrudable for smoother walls, greater flexibility and longer continuous lengths up to 200°C, whereas PTFE supports higher temperatures up to 260°C.
Where is FEP insulation commonly used?
In 200°C UL AWM and NEMA HP4 hook-up wires, aerospace and defence wiring, moisture-barrier thermocouple cables and low-loss instrumentation circuits.
Can FEP insulated cores be covered with an electron-beam cross-linked XLPE, LSZH or PUR jacket?
No — never pair FEP primary cores with an E-beam cross-linked or high-temperature peroxide CCV outer jacket. Ionising irradiation degrades FEP through backbone scission (causing brittle transverse cracking during stripping and bending), and CCV vulcanisation melts FEP (~260°C melt point). Use non-cross-linked thermoplastic jackets such as FEP, ETFE, TPU/PUR, TPE or PVC instead.
What conductor plating is recommended for 200°C FEP wire?
Use silver-plated copper (ASTM B298) or 2% nickel-plated copper (ASTM B355 Class 2) for continuous +200°C operation; tinned copper is best limited to ≤150°C–180°C because tin accelerates brittle copper-tin intermetallic growth near its 232°C melting point.

Engineering Guides