UL 758 AWM — Appliance & Equipment Wiring Material
Style-numbered component standard governing single-core hook-up wire, multi-conductor equipment cables, flat ribbon cables and RoundFlat assemblies inside industrial and electronic equipment.
Standard · Underwriters Laboratories (UL)
What is UL 758 AWM?
UL 758 is the Underwriters Laboratories standard for Appliance Wiring Material (AWM) — covering recognised factory-installed wiring inside appliances, control cabinets, industrial machinery, power supplies and electronics. Rather than defining a single cable design, UL 758 administers a comprehensive Style directory where each numbered Style fixes approved conductor gauges, insulation and jacket polymers, minimum wall thicknesses, shielding options, continuous temperature ratings and voltage classes.
Engineers specify by UL Style number because the Style defines the exact recognised envelope — spanning 80°C–105°C PVC hook-up wires, 125°C–150°C cross-linked XLPE wires, 150°C–200°C silicone rubber leads, 150°C–260°C fluoropolymers (PTFE, FEP, PFA, ETFE, PVDF), 250°C–550°C mica/fiberglass high-heat leads, multi-conductor control/instrumentation cables, flat ribbon cables and RoundFlat assemblies.
CASMO holds UL and cUL Component Recognition under File E535175 (verifiable on UL Product iQ, with certificates downloadable on our Quality & Compliance page) across PVC, XLPE, silicone rubber, fluoropolymer (PTFE, FEP, PFA, ETFE), mica/fiberglass, flat ribbon and RoundFlat styles. While PVC and fluoropolymer styles are inherently vertical-flame rated (VW-1), silicone, XLPE, TPE and TPU styles distinguish standard FT2 horizontal flame ratings (-TS2-) from optional VW-1 / FT1 vertical flame ratings (-TS1-).
Key Technical Requirements
| Parameter | Requirement | Notes |
|---|---|---|
| Recognition scope | UL Recognised Component (RU / cRU) | Internal & interconnection equipment wiring |
| Style directory | 4- or 5-digit Style numbers | Single-core, multicore, ribbon & RoundFlat |
| Voltage classes | 30V to 1000V+ (style dependent) | 300V and 600V most common for hook-up wire |
| Temperature range | 60°C to 550°C | PVC, XLPE, silicone, fluoropolymer & mica tiers |
| CASMO Recognition | UL / cUL File E535175 (RU / cRU) | Verifiable on UL Product iQ; certificates on Quality & Compliance page |
UL 758 AWM Products
- UL 20674 — UL 758 AWM · TPE · -40°C to +105°C · 150V
- UL 20596 — UL 758 AWM · PVC · -20°C to +105°C · 150V
- UL 20346 — UL 758 AWM · TPE · -40°C to +105°C · 300V
- UL 20297 — UL 758 AWM · TPE · -40°C to +105°C · 150V
- UL 20080 — UL 758 AWM · PVC · -20°C to +80°C · 30V
- UL 11856 — UL 758 AWM · TPE · -40°C to +105°C · 1000V
- UL 11627 — UL 758 AWM · PVC · -20°C to +105°C · 2000V
- UL 11170 — UL 758 AWM · PVC · -20°C to +80°C · 600V
- UL 11150 — UL 758 AWM · TPE · -40°C to +105°C · 300V
- UL 11122 — UL 758 AWM · PVC · -20°C to +105°C · 1000V
- UL 10921 — UL 758 AWM · SR-PVC · -20°C to +105°C · 300V
- UL 10666 — UL 758 AWM · TPE · -40°C to +105°C · 600V
- UL 10368 — UL 758 AWM · XLPE · -40°C to +105°C · 300V
- UL 10269 — UL 758 AWM · PVC · -40°C to +105°C · 1000V
- UL 10198 — UL 758 AWM · PVC · -20°C to +105°C · 300V
- UL 10106 — UL 758 AWM · TPE · -40°C to +90°C · 300V
- UL 10086 — UL 758 AWM · ETFE · -60°C to +200°C · 600V
- UL 10002 — UL 758 AWM · SR-PVC · -20°C to +105°C · 300V
- UL 5562 — UL 758 AWM · Mica tape · 550°C · 600V
- UL 5561 — UL 758 AWM · Mica tape · 550°C · 300V
- UL 5360 — UL 758 AWM · Mica tape · 450°C · 300V
- UL 5359 — UL 758 AWM · Mica tape · 450°C · 600V
- UL 5256 — UL 758 AWM · PTFE / Glass serve · 250°C · 600V
- UL 5196 — UL 758 AWM · PTFE / Glass serve · 250°C · 600V
- UL 5128 — UL 758 AWM · Mica tape · 450°C · 300V
- UL 5107 — UL 758 AWM · Mica tape · 450°C · 600V
- UL 4478 — UL 758 AWM · XLPE · -20°C to +105°C · 300V
- UL 3530 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
- UL 3529 — UL 758 AWM · Silicone rubber · -60°C to +150°C · 600V
- UL 3513 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
- UL 3512 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
- UL 3398 — UL 758 AWM · XLPE · -40°C to +150°C · 300V
- UL 3386 — UL 758 AWM · XLPE · -40°C to +105°C · 600V
- UL 3385 — UL 758 AWM · XLPE · -40°C to +105°C · 300V
- UL 3367 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 300V
- UL 3321 — UL 758 AWM · XLPE · -40°C to +150°C · 600V
- UL 3302 — UL 758 AWM · XLPE · -20°C to +105°C · 30V
- UL 3289 — UL 758 AWM · XLPE · -40°C to +150°C · 600V
- UL 3272 — UL 758 AWM · XLPE · -40°C to +125°C · 600V
- UL 3271 — UL 758 AWM · XLPE · -40°C to +125°C · 600V
- UL 3266 — UL 758 AWM · XLPE · -40°C to +125°C · 300V
- UL 3265 — UL 758 AWM · XLPE · -40°C to +125°C · 150V
- UL 3173 — UL 758 AWM · XLPE · -40°C to +125°C · 600V
- UL 3172 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
- UL 3135 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
- UL 3133 — UL 758 AWM · Silicone rubber · -60°C to +150°C · 600V
- UL 3132 — UL 758 AWM · Silicone rubber · -60°C to +150°C · 300V
- UL 3122 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 300V
- UL 3075 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
- UL 3074 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
- UL 3071 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
- UL 3069 — UL 758 AWM · Silicone rubber · -60°C to +150°C · 600V
- UL 3068 — UL 758 AWM · Silicone rubber · -60°C to +150°C · 300V
- UL 2678 — UL 758 AWM · PVC · -20°C to +105°C · 150V
- UL 2651 — UL 758 AWM · PVC · -20°C to +105°C · 300V
- UL 2587 — UL 758 AWM · PVC · -20°C to +90°C · 600V
- UL 2576 — UL 758 AWM · SR-PVC · -20°C to +80°C · 150V
- UL 2517 — UL 758 AWM · PVC · -20°C to +105°C · 300V
- UL 2468 — UL 758 AWM · PVC · -20°C to +80°C · 300V
- UL 2464 — UL 758 AWM · SR-PVC · -20°C to +80°C · 300V
- UL 1887 — UL 758 AWM · FEP · -60°C to +150°C · 600V
- UL 1859 — UL 758 AWM · PFA · -60°C to +150°C · 600V
- UL 1858 — UL 758 AWM · PFA · -60°C to +150°C · 300V
- UL 1729 — UL 758 AWM · PVC · -20°C to +80°C · 300V
- UL 1710 — UL 758 AWM · PFA · -60°C to +200°C · 600V
- UL 1709 — UL 758 AWM · PFA · -60°C to +200°C · 300V
- UL 1672 — UL 758 AWM · PVC · -20°C to +105°C · 300V
- UL 1571 — UL 758 AWM · PVC · -20°C to +80°C · 30V
- UL 1430 — UL 758 AWM · XL-PVC · -20°C to +105°C · 300V
- UL 1333 — UL 758 AWM · FEP · -60°C to +150°C · 300V
- UL 1332 — UL 758 AWM · FEP · -60°C to +200°C · 300V
- UL 1331 — UL 758 AWM · FEP · -60°C to +150°C · 600V
- UL 1330 — UL 758 AWM · FEP · -60°C to +200°C · 600V
- UL 1284 — UL 758 AWM · PVC · -20°C to +105°C · 600V
- UL 1213 — UL 758 AWM · PTFE · -60°C to +105°C
- UL 1199 — UL 758 AWM · PTFE · -60°C to +200°C · 600V
- UL 1180 — UL 758 AWM · PTFE · -60°C to +200°C · 300V
- UL 1120 — UL 758 AWM · PVC · -20°C to +105°C · 600V
- UL 1095 — UL 758 AWM · PVC · -20°C to +80°C · 300V
- UL 1061 — UL 758 AWM · SR-PVC · -20°C to +80°C · 300V
- UL 1032 — UL 758 AWM · PVC · -20°C to +90°C · 1000V
- UL 1028 — UL 758 AWM · PVC · -20°C to +105°C · 600V
- ROUNDFLAT UNSHIELDED — UL 758 AWM · PVC · -20°C to +80°C · 30V
- ROUNDFLAT SHIELDED — UL 758 AWM · PVC · -20°C to +80°C · 30V
- UL 1283 — UL 758 AWM · PVC · -20°C to +105°C · 600V
- UL 1015 — UL 758 AWM · PVC · -20°C to +105°C · 600V
- UL 1007 / 1569 — UL 758 AWM · PVC · 1007: -20°C to +80°C / 1569: -20°C to +105°C · 1007: 300V / 1569: 300V
Insulation Materials in This Standard
Frequently Asked Questions
- What does AWM stand for under UL 758?
- Appliance Wiring Material — UL's component recognition category covering wires and multi-conductor cables used inside factory-built appliances, machinery and electronic assemblies.
- What is the difference between Style 1007 and Style 1015?
- Both are PVC single-core hook-up wires; Style 1015 uses thicker insulation rated 600V / 105°C, whereas Style 1007 uses a slimmer wall rated 300V / 80°C for compact internal routing.
- Does UL 758 cover multi-conductor and flat ribbon cables as well as single-core wire?
- Yes — UL 758 covers single-core hook-up wires, shielded and unshielded multi-conductor equipment cables, flat parallel ribbon cables and round-jacketed RoundFlat cables under distinct Style numbers.
- Are UL 758 AWM wires UL Listed or UL Recognised?
- AWM cables carry UL Component Recognition (RU / cRU) for integration inside listed end-use equipment rather than standalone NEC building installation.
Engineering Guides
- XLPE Cross-Linking Methods Compared: Electron-Beam Irradiation vs. Chemical Peroxide (CCV) vs. Silane (Sioplas & Monosil) — How electron-beam irradiation, chemical peroxide CCV curing, and silane moisture cross-linking convert polyethylene into thermoset XLPE — comparing thermal rating, wall-thickness limits, scorch risk, hot-set QC testing, and XLPE/XLPO/XLPVC/XL-ETFE wire standards.
- Why FEP & PTFE Insulated Cores Cannot Use Cross-Linked Jackets: E-Beam, Peroxide, Silane, and Silicone Compatibility Guide — Real failure-analysis photos and polymer-physics guide explaining why cross-linked PUR, rubber, and XLPE jackets cause brittle cracking and fracture in FEP/PTFE primary cores — plus safe hybrid alternatives.