UL 758 AWM — Appliance & Equipment Wiring Material

Style-numbered component standard governing single-core hook-up wire, multi-conductor equipment cables, flat ribbon cables and RoundFlat assemblies inside industrial and electronic equipment.

Standard · Underwriters Laboratories (UL)

What is UL 758 AWM?

UL 758 is the Underwriters Laboratories standard for Appliance Wiring Material (AWM) — covering recognised factory-installed wiring inside appliances, control cabinets, industrial machinery, power supplies and electronics. Rather than defining a single cable design, UL 758 administers a comprehensive Style directory where each numbered Style fixes approved conductor gauges, insulation and jacket polymers, minimum wall thicknesses, shielding options, continuous temperature ratings and voltage classes.

Engineers specify by UL Style number because the Style defines the exact recognised envelope — spanning 80°C–105°C PVC hook-up wires, 125°C–150°C cross-linked XLPE wires, 150°C–200°C silicone rubber leads, 150°C–260°C fluoropolymers (PTFE, FEP, PFA, ETFE, PVDF), 250°C–550°C mica/fiberglass high-heat leads, multi-conductor control/instrumentation cables, flat ribbon cables and RoundFlat assemblies.

CASMO holds UL and cUL Component Recognition under File E535175 (verifiable on UL Product iQ, with certificates downloadable on our Quality & Compliance page) across PVC, XLPE, silicone rubber, fluoropolymer (PTFE, FEP, PFA, ETFE), mica/fiberglass, flat ribbon and RoundFlat styles. While PVC and fluoropolymer styles are inherently vertical-flame rated (VW-1), silicone, XLPE, TPE and TPU styles distinguish standard FT2 horizontal flame ratings (-TS2-) from optional VW-1 / FT1 vertical flame ratings (-TS1-).

Key Technical Requirements

ParameterRequirementNotes
Recognition scopeUL Recognised Component (RU / cRU)Internal & interconnection equipment wiring
Style directory4- or 5-digit Style numbersSingle-core, multicore, ribbon & RoundFlat
Voltage classes30V to 1000V+ (style dependent)300V and 600V most common for hook-up wire
Temperature range60°C to 550°CPVC, XLPE, silicone, fluoropolymer & mica tiers
CASMO RecognitionUL / cUL File E535175 (RU / cRU)Verifiable on UL Product iQ; certificates on Quality & Compliance page

UL 758 AWM Products

  • UL 20674 — UL 758 AWM · TPE · -40°C to +105°C · 150V
  • UL 20596 — UL 758 AWM · PVC · -20°C to +105°C · 150V
  • UL 20346 — UL 758 AWM · TPE · -40°C to +105°C · 300V
  • UL 20297 — UL 758 AWM · TPE · -40°C to +105°C · 150V
  • UL 20080 — UL 758 AWM · PVC · -20°C to +80°C · 30V
  • UL 11856 — UL 758 AWM · TPE · -40°C to +105°C · 1000V
  • UL 11627 — UL 758 AWM · PVC · -20°C to +105°C · 2000V
  • UL 11170 — UL 758 AWM · PVC · -20°C to +80°C · 600V
  • UL 11150 — UL 758 AWM · TPE · -40°C to +105°C · 300V
  • UL 11122 — UL 758 AWM · PVC · -20°C to +105°C · 1000V
  • UL 10921 — UL 758 AWM · SR-PVC · -20°C to +105°C · 300V
  • UL 10666 — UL 758 AWM · TPE · -40°C to +105°C · 600V
  • UL 10368 — UL 758 AWM · XLPE · -40°C to +105°C · 300V
  • UL 10269 — UL 758 AWM · PVC · -40°C to +105°C · 1000V
  • UL 10198 — UL 758 AWM · PVC · -20°C to +105°C · 300V
  • UL 10106 — UL 758 AWM · TPE · -40°C to +90°C · 300V
  • UL 10086 — UL 758 AWM · ETFE · -60°C to +200°C · 600V
  • UL 10002 — UL 758 AWM · SR-PVC · -20°C to +105°C · 300V
  • UL 5562 — UL 758 AWM · Mica tape · 550°C · 600V
  • UL 5561 — UL 758 AWM · Mica tape · 550°C · 300V
  • UL 5360 — UL 758 AWM · Mica tape · 450°C · 300V
  • UL 5359 — UL 758 AWM · Mica tape · 450°C · 600V
  • UL 5256 — UL 758 AWM · PTFE / Glass serve · 250°C · 600V
  • UL 5196 — UL 758 AWM · PTFE / Glass serve · 250°C · 600V
  • UL 5128 — UL 758 AWM · Mica tape · 450°C · 300V
  • UL 5107 — UL 758 AWM · Mica tape · 450°C · 600V
  • UL 4478 — UL 758 AWM · XLPE · -20°C to +105°C · 300V
  • UL 3530 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
  • UL 3529 — UL 758 AWM · Silicone rubber · -60°C to +150°C · 600V
  • UL 3513 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
  • UL 3512 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
  • UL 3398 — UL 758 AWM · XLPE · -40°C to +150°C · 300V
  • UL 3386 — UL 758 AWM · XLPE · -40°C to +105°C · 600V
  • UL 3385 — UL 758 AWM · XLPE · -40°C to +105°C · 300V
  • UL 3367 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 300V
  • UL 3321 — UL 758 AWM · XLPE · -40°C to +150°C · 600V
  • UL 3302 — UL 758 AWM · XLPE · -20°C to +105°C · 30V
  • UL 3289 — UL 758 AWM · XLPE · -40°C to +150°C · 600V
  • UL 3272 — UL 758 AWM · XLPE · -40°C to +125°C · 600V
  • UL 3271 — UL 758 AWM · XLPE · -40°C to +125°C · 600V
  • UL 3266 — UL 758 AWM · XLPE · -40°C to +125°C · 300V
  • UL 3265 — UL 758 AWM · XLPE · -40°C to +125°C · 150V
  • UL 3173 — UL 758 AWM · XLPE · -40°C to +125°C · 600V
  • UL 3172 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
  • UL 3135 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
  • UL 3133 — UL 758 AWM · Silicone rubber · -60°C to +150°C · 600V
  • UL 3132 — UL 758 AWM · Silicone rubber · -60°C to +150°C · 300V
  • UL 3122 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 300V
  • UL 3075 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
  • UL 3074 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
  • UL 3071 — UL 758 AWM · Silicone rubber · -60°C to +200°C · 600V
  • UL 3069 — UL 758 AWM · Silicone rubber · -60°C to +150°C · 600V
  • UL 3068 — UL 758 AWM · Silicone rubber · -60°C to +150°C · 300V
  • UL 2678 — UL 758 AWM · PVC · -20°C to +105°C · 150V
  • UL 2651 — UL 758 AWM · PVC · -20°C to +105°C · 300V
  • UL 2587 — UL 758 AWM · PVC · -20°C to +90°C · 600V
  • UL 2576 — UL 758 AWM · SR-PVC · -20°C to +80°C · 150V
  • UL 2517 — UL 758 AWM · PVC · -20°C to +105°C · 300V
  • UL 2468 — UL 758 AWM · PVC · -20°C to +80°C · 300V
  • UL 2464 — UL 758 AWM · SR-PVC · -20°C to +80°C · 300V
  • UL 1887 — UL 758 AWM · FEP · -60°C to +150°C · 600V
  • UL 1859 — UL 758 AWM · PFA · -60°C to +150°C · 600V
  • UL 1858 — UL 758 AWM · PFA · -60°C to +150°C · 300V
  • UL 1729 — UL 758 AWM · PVC · -20°C to +80°C · 300V
  • UL 1710 — UL 758 AWM · PFA · -60°C to +200°C · 600V
  • UL 1709 — UL 758 AWM · PFA · -60°C to +200°C · 300V
  • UL 1672 — UL 758 AWM · PVC · -20°C to +105°C · 300V
  • UL 1571 — UL 758 AWM · PVC · -20°C to +80°C · 30V
  • UL 1430 — UL 758 AWM · XL-PVC · -20°C to +105°C · 300V
  • UL 1333 — UL 758 AWM · FEP · -60°C to +150°C · 300V
  • UL 1332 — UL 758 AWM · FEP · -60°C to +200°C · 300V
  • UL 1331 — UL 758 AWM · FEP · -60°C to +150°C · 600V
  • UL 1330 — UL 758 AWM · FEP · -60°C to +200°C · 600V
  • UL 1284 — UL 758 AWM · PVC · -20°C to +105°C · 600V
  • UL 1213 — UL 758 AWM · PTFE · -60°C to +105°C
  • UL 1199 — UL 758 AWM · PTFE · -60°C to +200°C · 600V
  • UL 1180 — UL 758 AWM · PTFE · -60°C to +200°C · 300V
  • UL 1120 — UL 758 AWM · PVC · -20°C to +105°C · 600V
  • UL 1095 — UL 758 AWM · PVC · -20°C to +80°C · 300V
  • UL 1061 — UL 758 AWM · SR-PVC · -20°C to +80°C · 300V
  • UL 1032 — UL 758 AWM · PVC · -20°C to +90°C · 1000V
  • UL 1028 — UL 758 AWM · PVC · -20°C to +105°C · 600V
  • ROUNDFLAT UNSHIELDED — UL 758 AWM · PVC · -20°C to +80°C · 30V
  • ROUNDFLAT SHIELDED — UL 758 AWM · PVC · -20°C to +80°C · 30V
  • UL 1283 — UL 758 AWM · PVC · -20°C to +105°C · 600V
  • UL 1015 — UL 758 AWM · PVC · -20°C to +105°C · 600V
  • UL 1007 / 1569 — UL 758 AWM · PVC · 1007: -20°C to +80°C / 1569: -20°C to +105°C · 1007: 300V / 1569: 300V

Insulation Materials in This Standard

Frequently Asked Questions

What does AWM stand for under UL 758?
Appliance Wiring Material — UL's component recognition category covering wires and multi-conductor cables used inside factory-built appliances, machinery and electronic assemblies.
What is the difference between Style 1007 and Style 1015?
Both are PVC single-core hook-up wires; Style 1015 uses thicker insulation rated 600V / 105°C, whereas Style 1007 uses a slimmer wall rated 300V / 80°C for compact internal routing.
Does UL 758 cover multi-conductor and flat ribbon cables as well as single-core wire?
Yes — UL 758 covers single-core hook-up wires, shielded and unshielded multi-conductor equipment cables, flat parallel ribbon cables and round-jacketed RoundFlat cables under distinct Style numbers.
Are UL 758 AWM wires UL Listed or UL Recognised?
AWM cables carry UL Component Recognition (RU / cRU) for integration inside listed end-use equipment rather than standalone NEC building installation.

Engineering Guides