UL 3075
UL 3075 is a CASMO hook-up wire for UL AWM. Silicone rubber insulated, -60°C to +200°C, 600V. UL 3075 10 AWG fiberglass-braided silicone rubber lead wire rated -60°C to +200°C and 600V AC for high-temperature internal equipment and appliance power leads.
UL 3075 10 AWG fiberglass-braided silicone rubber lead wire rated -60°C to +200°C and 600V AC for high-temperature internal equipment and appliance power leads.
Key Ratings
- 3075: · Temperature -60°C to +200°C · Rated Voltage 600V
Construction
- Conductor
- Nickel Plated Copper · Stranded
- Insulation
- Extruded · Silicone rubber
- Braid
- Fiberglass
Characteristics
- Abrasion Resistance: Resistant to abrasion, helping protect the cable surface against wear caused by rubbing and handling.
- Low-Temperature Flexibility: Maintains flexibility at low temperatures, facilitating cable routing and handling in cold environments.
- Moisture Resistance: Resistant to moisture and humidity, helping maintain the integrity of the cable covering in damp environments.
Applications
- Internal Equipment Wiring: For internal wiring of electrical and electronic equipment, subject to the applicable voltage, temperature and installation requirements.
- Appliances: For internal wiring of household and commercial appliances, subject to the applicable equipment requirements.
- Control Cabinets: For wiring within control cabinets, control panels and electrical assemblies.
Standards & Compliance
- Standard: UL 758 AWM
- Fire Performance: VW-1, FT1, FT2
- RoHS: Compliant
- REACH: Compliant
Specifications
| CASMO Part No. | Conductor Size (AWG) | No. Of Strands | Nom. Strand Dia. (mm) | Nom. Conductor Dia. (mm) | Nom. Ins. Thickness (mm) | Min. Ins. Thickness (mm) | Nom. Braid Thickness (mm) | Nom. O.D. (mm) | Max. DCR @20°C (Ω/km) |
|---|---|---|---|---|---|---|---|---|---|
| 3210510/105-NS2-XX | 10 | 105 | 0.254 | 3.00 | 1.14 | 1.02 | 0.11 | 5.50 | 3.68 |
"-NS2-" = nickel-plated copper conductor with FT2 flame rating (standard). "-NS1-" = nickel-plated copper conductor with VW-1 / FT1 flame rating (optional). Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
- "-NS2-" = nickel-plated copper conductor with FT2 flame rating (standard). "-NS1-" = nickel-plated copper conductor with VW-1 / FT1 flame rating (optional).
- Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.