UL 11856
UL 11856 is a CASMO hook-up wire for UL AWM. TPE insulated, -40°C to +105°C, 1000V. UL11856 — 1000 Vac, 105 °C TPE hook-up wire for internal wiring of appliances and electronic equipment.
UL11856 — 1000 Vac, 105 °C TPE hook-up wire for internal wiring of appliances and electronic equipment.
Key Ratings
- 11856: · Temperature -40°C to +105°C · Rated Voltage 1000V
Construction
- Conductor
- Tinned Copper or Bare Copper
- Insulation
- Extruded · TPE
Characteristics
- Flexible & Resilient: Elastomeric TPE insulation delivers supple flexibility and good flex-life in compact wiring assemblies.
- Abrasion & Pinch Resistance: Tough thermoplastic elastomer resists abrasion, pinching, and cold-temperature cracking.
Applications
- Internal wiring: Internal wiring of appliances and electronic equipment.
Standards & Compliance
- Standard: UL 758 AWM
- Fire Performance: VW-1, FT1, FT2
- RoHS: Compliant
- REACH: Compliant
UL11856
| CASMO Part No. | Conductor Size (AWG) | No. Of Strands | Nom. Strand Dia. (mm) | Nom. Conductor Dia. (mm) | Nom. Ins. Thickness (mm) | Min. Ins. Thickness (mm) | Nom. O.D. (mm) | Max. DCR @20°C (Ω/km) | Nom. Cable Weight (kg/km) |
|---|---|---|---|---|---|---|---|---|---|
| 12210430/7-TS2-XX | 30 | 7 | 0.1 | 0.3 | 0.23 | 0.2 | 0.8 | 381 | 1.04 |
| 12210428/7-TS2-XX | 28 | 7 | 0.127 | 0.38 | 0.23 | 0.2 | 0.9 | 239 | 1.5 |
| 12210426/7-TS2-XX | 26 | 7 | 0.16 | 0.48 | 0.23 | 0.2 | 1 | 150 | 2.18 |
| 12210424/11-TS2-XX | 24 | 11 | 0.16 | 0.61 | 0.23 | 0.2 | 1.1 | 94.2 | 3.22 |
| 12210424/19-TS2-XX | 24 | 19 | 0.127 | 0.64 | 0.23 | 0.2 | 1.1 | 94.2 | 3.46 |
| 12210422/7-TS2-XX | 22 | 7 | 0.254 | 0.76 | 0.23 | 0.2 | 1.3 | 59.4 | 4.86 |
| 12210422/17-TS2-XX | 22 | 17 | 0.16 | 0.76 | 0.23 | 0.2 | 1.3 | 59.4 | 4.86 |
| 12210420/19-TS2-XX | 20 | 19 | 0.2 | 1 | 0.23 | 0.2 | 1.5 | 36.7 | 7.91 |
| 12210420/26-TS2-XX | 20 | 26 | 0.16 | 0.94 | 0.23 | 0.2 | 1.5 | 36.7 | 7.19 |
| 12210420/41-TS2-XX | 20 | 41 | 0.127 | 0.94 | 0.23 | 0.2 | 1.5 | 36.7 | 7.19 |
| 12210418/19-TS2-XX | 18 | 19 | 0.254 | 1.27 | 0.23 | 0.2 | 1.8 | 23.2 | 12.48 |
| 12210418/41-TS2-XX | 18 | 41 | 0.16 | 1.18 | 0.23 | 0.2 | 1.8 | 23.2 | 11.1 |
| 12210416/26-TS2-XX | 16 | 26 | 0.254 | 1.49 | 0.23 | 0.2 | 2.2 | 14.6 | 17.46 |
| 12210416/65-TS2-XX | 16 | 65 | 0.16 | 1.5 | 0.23 | 0.2 | 2.2 | 14.6 | 17.64 |
* Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. † "-TS2-" = tinned copper conductor with FT2 flame rating (standard). "-TS1-" = tinned copper conductor with VW-1 / FT1 flame rating (optional).
- Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
- "-TS2-" = tinned copper conductor with FT2 flame rating (standard). "-TS1-" = tinned copper conductor with VW-1 / FT1 flame rating (optional).