UL 1061

UL 1061 is a CASMO hook-up wire for UL AWM. SR-PVC insulated, -20°C to +80°C, 300V. UL1061 — 300 Vac, 80 °C SRPVC hook-up wire for internal wiring of appliances and electronic equipment.

UL1061 — 300 Vac, 80 °C SRPVC hook-up wire for internal wiring of appliances and electronic equipment.

Key Ratings

  • 1061: · Temperature -20°C to +80°C · Rated Voltage 300V

Construction

Conductor
Bare copper or Tin-plated copper
Insulation
Extruded · SR-PVC

Characteristics

  • Oil & Fluid Resistance: Good resistance to oils, greases, and common industrial fluids.
  • Flexible: Flexible stranded construction for easy routing and installation in confined spaces.

Applications

  • Internal wiring: Internal wiring of appliances and electronic equipment.

Standards & Compliance

  • Standard: UL 758 AWM
  • Fire Performance: VW-1, FT1
  • RoHS: Compliant
  • REACH: Compliant

UL1061

CASMO Part No.Conductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Min. Ins. Thickness (mm)Nom. O.D. (mm)Max. DCR @20°C (Ω/km)Nom. Cable Weight (kg/km)
411030/7-TS-XX3070.10.30.230.180.83811.08
411028/7-TS-XX2870.1270.380.230.180.92391.51
411026/7-TS-XX2670.160.480.230.1811502.09
411024/11-TS-XX24110.160.610.230.181.194.22.87
411024/19-TS-XX24190.1270.640.230.181.194.23.01
411022/7-TS-XX2270.2540.760.230.181.359.44.36
411022/17-TS-XX22170.160.760.230.181.359.44.24
411020/19-TS-XX20190.210.230.181.536.76.66
411020/26-TS-XX20260.160.940.230.181.536.76.13
411020/41-TS-XX20410.1270.940.230.181.536.76.1
411018/19-TS-XX18190.2541.270.230.181.823.210.32
411018/41-TS-XX18410.161.180.230.181.823.29.33
411016/26-TS-XX16260.2541.490.230.182.114.614.09
411016/65-TS-XX16650.161.50.230.182.114.613.96
411014/41-TS-XX14410.2541.880.230.182.508.9621.41
411014/104-TS-XX141040.161.890.230.182.508.9621.49

* -40°C versions are available on special request. † Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. ‡ "-TS-" = tinned copper conductor, "-AS-" = bare copper conductor; TS and AS may be substituted for each other.

  • -40°C versions are available on special request.
  • Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
  • "-TS-" = tinned copper conductor, "-AS-" = bare copper conductor; TS and AS may be substituted for each other.