UL 1672

UL 1672 is a CASMO hook-up wire for UL AWM. PVC insulated, -20°C to +105°C, 300V.

Key Ratings

  • 1672: · Temperature -20°C to +105°C · Rated Voltage 300V

Construction

Conductor
Bare copper or Tin-plated copper
Insulation
Extruded · PVC
Jacket
Extruded · PVC

Characteristics

  • Dual-Layer Insulation: Extruded primary PVC insulation plus outer PVC jacket provides redundant dielectric and mechanical protection.
  • Easy Stripping & Processing: Clean dual-layer separation for automated cutting, stripping, and terminal crimping.
  • Oil & Moisture Resistance: Resistant to oils, moisture, fungus, and common industrial fluids.

Applications

  • Internal Wiring: Internal wiring of appliances and electronic equipment.

Standards & Compliance

  • Standard: UL 758 AWM
  • Fire Performance: VW-1, FT1
  • RoHS: Compliant
  • REACH: Compliant

UL1672

CASMO Part No.Conductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Min. Ins. Thickness (mm)Nom. Jkt. Thickness (mm)Min. Jkt. Thickness (mm)Nom. O.D. (mm)Max. DCR @20°C (Ω/km)Nom. Cable Weight (kg/km)
413826/7-TS-XX2670.160.480.380.330.380.332.051505.8
413824/11-TS-XX24110.160.610.380.330.380.332.2094.27.1
413824/19-TS-XX24190.1270.640.380.330.380.332.2094.27.2
413822/7-TS-XX2270.2540.760.380.330.380.332.3559.48.9
413822/17-TS-XX22170.160.760.380.330.380.332.3559.48.8
413820/10-TS-XX20100.2540.930.380.330.380.332.6036.711.5
413820/21-TS-XX20210.1780.940.380.330.380.332.6036.711.6
413820/26-TS-XX20260.160.940.380.330.380.332.6036.711.6
413818/16-TS-XX18160.2541.170.380.330.380.332.8523.215.2
413818/34-TS-XX18340.1781.210.380.330.380.332.8523.215.4
413816/26-TS-XX16260.2541.490.380.330.380.333.0514.620.4
413816/65-TS-XX16650.161.490.380.330.380.333.0514.620.3

* Part No. code: XX = outer jacket colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey (inner primary insulation standard colour: White). † "-TS-" = tinned copper conductor, "-AS-" = bare copper conductor; TS and AS may be substituted for each other.

  • Part No. code: XX = outer jacket colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey (inner primary insulation standard colour: White).
  • "-TS-" = tinned copper conductor, "-AS-" = bare copper conductor; TS and AS may be substituted for each other.