UL 3385

UL 3385 is a CASMO hook-up wire for UL AWM. XLPE insulated, -40°C to +105°C, 300V.

Key Ratings

  • 3385: · Temperature -40°C to +105°C · Rated Voltage 300V

Construction

Conductor
Tinned Copper or Bare Copper
Insulation
Extruded · XLPE

Characteristics

  • Abrasion & Cut-Through Resistance: Tough cross-linked insulation with excellent resistance to abrasion, deformation, and cut-through.
  • Soldering Heat Resistance: Thermoset cross-linked insulation will not melt or flow at soldering temperatures.

Applications

  • Internal wiring: Internal wiring of appliances and electronic equipment.

Standards & Compliance

  • Standard: UL 758 AWM
  • Fire Performance: VW-1, FT1, FT2
  • RoHS: Compliant
  • REACH: Compliant

UL3385

CASMO Part No.Conductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Min. Ins. Thickness (mm)Nom. O.D. (mm)Max. DCR @20°C (Ω/km)Nom. Cable Weight (kg/km)
12110730/7-TS2-XX3070.10.30.380.331.13811.31
12110728/7-TS2-XX2870.1270.380.380.331.22391.73
12110726/7-TS2-XX2670.160.480.380.331.31502.32
12110724/11-TS2-XX24110.160.610.380.331.494.23.13
12110724/19-TS2-XX24190.1270.640.380.331.494.23.27
12110722/7-TS2-XX2270.2540.760.380.331.659.44.6
12110722/17-TS2-XX22170.160.760.380.331.659.44.49
12110720/19-TS2-XX20190.210.380.331.836.76.94
12110720/26-TS2-XX20260.160.940.380.331.836.76.37
12110720/41-TS2-XX20410.1270.940.380.331.836.76.34
12110718/19-TS2-XX18190.2541.270.380.332.123.210.6
12110718/41-TS2-XX18410.161.180.380.332.123.29.53
12110716/26-TS2-XX16260.2541.490.380.332.414.614.3
12110716/65-TS2-XX16650.161.50.380.332.414.614.18
12110714/41-TS2-XX14410.2541.880.380.332.88.9621.61
12110714/104-TS2-XX141040.161.890.380.332.88.9621.71
12110712/65-TS2-XX12650.2542.360.380.333.45.6433.66
12110712/168-TS2-XX121680.162.370.380.333.45.6434.37
12110710/105-TS2-XX101050.2542.980.380.3343.5450.44
12110710/259-TS2-XX102590.162.970.380.3343.5451.54

* Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. † "-TS2-" = tinned copper conductor with FT2 flame rating (standard). "-TS1-" = tinned copper conductor with VW-1 / FT1 flame rating (optional).

  • Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
  • "-TS2-" = tinned copper conductor with FT2 flame rating (standard). "-TS1-" = tinned copper conductor with VW-1 / FT1 flame rating (optional).