UL 3272
UL 3272 is a CASMO hook-up wire for UL AWM. XLPE insulated, -40°C to +125°C, 600V. UL3272 — 600 Vac, 125 °C XLPE hook-up wire for internal wiring of appliances and electronic equipment.
UL3272 — 600 Vac, 125 °C XLPE hook-up wire for internal wiring of appliances and electronic equipment.
Key Ratings
- 3272: · Temperature -40°C to +125°C · Rated Voltage 600V
Construction
- Conductor
- Tinned Copper or Bare Copper
- Insulation
- Extruded · XLPE
Characteristics
- Abrasion & Cut-Through Resistance: Tough cross-linked insulation with excellent resistance to abrasion, deformation, and cut-through.
- Soldering Heat Resistance: Thermoset cross-linked insulation will not melt or flow at soldering temperatures.
Applications
- Internal wiring: Internal wiring of appliances and electronic equipment.
Standards & Compliance
- Standard: UL 758 AWM
- Fire Performance: VW-1, FT1, FT2
- RoHS: Compliant
- REACH: Compliant
UL3272
| CASMO Part No. | Conductor Size (AWG) | No. Of Strands | Nom. Strand Dia. (mm) | Nom. Conductor Dia. (mm) | Nom. Ins. Thickness (mm) | Min. Ins. Thickness (mm) | Nom. O.D. (mm) | Max. DCR @20°C (Ω/km) | Nom. Cable Weight (kg/km) |
|---|---|---|---|---|---|---|---|---|---|
| 12113226/7-TS2-XX | 26 | 7 | 0.16 | 0.48 | 0.76 | 0.69 | 2.1 | 150 | 4.3 |
| 12113224/11-TS2-XX | 24 | 11 | 0.16 | 0.61 | 0.76 | 0.69 | 2.25 | 94.2 | 5.39 |
| 12113224/19-TS2-XX | 24 | 19 | 0.127 | 0.64 | 0.76 | 0.69 | 2.25 | 94.2 | 5.54 |
| 12113222/7-TS2-XX | 22 | 7 | 0.254 | 0.76 | 0.76 | 0.69 | 2.3 | 59.4 | 6.6 |
| 12113222/17-TS2-XX | 22 | 17 | 0.16 | 0.76 | 0.76 | 0.69 | 2.3 | 59.4 | 6.48 |
| 12113220/19-TS2-XX | 20 | 19 | 0.2 | 1 | 0.76 | 0.69 | 2.52 | 36.7 | 9.14 |
| 12113220/26-TS2-XX | 20 | 26 | 0.16 | 0.94 | 0.76 | 0.69 | 2.52 | 36.7 | 8.57 |
| 12113220/41-TS2-XX | 20 | 41 | 0.127 | 0.94 | 0.76 | 0.69 | 2.52 | 36.7 | 8.54 |
| 12113218/19-TS2-XX | 18 | 19 | 0.254 | 1.27 | 0.76 | 0.69 | 2.79 | 23.2 | 12.9 |
| 12113218/41-TS2-XX | 18 | 41 | 0.16 | 1.18 | 0.76 | 0.69 | 2.79 | 23.2 | 11.84 |
| 12113216/26-TS2-XX | 16 | 26 | 0.254 | 1.49 | 0.76 | 0.69 | 3.1 | 14.6 | 17.11 |
| 12113216/65-TS2-XX | 16 | 65 | 0.16 | 1.5 | 0.76 | 0.69 | 3.1 | 14.6 | 16.99 |
| 12113214/41-TS2-XX | 14 | 41 | 0.254 | 1.88 | 0.76 | 0.69 | 3.5 | 8.96 | 24.84 |
| 12113214/104-TS2-XX | 14 | 104 | 0.16 | 1.89 | 0.76 | 0.69 | 3.5 | 8.96 | 24.93 |
| 12113212/65-TS2-XX | 12 | 65 | 0.254 | 2.36 | 0.76 | 0.69 | 4 | 5.64 | 36.9 |
| 12113212/168-TS2-XX | 12 | 168 | 0.16 | 2.37 | 0.76 | 0.69 | 4 | 5.64 | 37.61 |
| 12113210/105-TS2-XX | 10 | 105 | 0.254 | 2.98 | 0.76 | 0.69 | 4.80 | 3.54 | 57.64 |
| 12113210/259-TS2-XX | 10 | 259 | 0.16 | 2.97 | 0.76 | 0.69 | 4.80 | 3.54 | 56.68 |
| 1211328/168-TS2-XX | 8 | 168 | 0.254 | 3.8 | 1.14 | 1.04 | 6.7 | 2.23 | 96.84 |
| 1211328/420-TS2-XX | 8 | 420 | 0.16 | 3.78 | 1.14 | 1.04 | 6.7 | 2.23 | 97.42 |
| 1211326/266-TS2-XX | 6 | 266 | 0.254 | 4.75 | 1.14 | 1.04 | 7.6 | 1.4 | 145.53 |
| 1211326/665-TS2-XX | 6 | 665 | 0.16 | 4.75 | 1.14 | 1.04 | 7.6 | 1.4 | 144.57 |
| 1211324/133-TS2-XX | 4 | 133 | 0.45 | 5.98 | 1.14 | 1.04 | 9.1 | 0.9 | 222.41 |
| 1211324/420-TS2-XX | 4 | 420 | 0.254 | 5.98 | 1.14 | 1.04 | 9.1 | 0.9 | 223.56 |
| 1211324/1064-TS2-XX | 4 | 1064 | 0.16 | 5.98 | 1.14 | 1.04 | 9.1 | 0.9 | 224.55 |
* Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. † "-TS2-" = tinned copper conductor with FT2 flame rating (standard). "-TS1-" = tinned copper conductor with VW-1 / FT1 flame rating (optional).
- Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
- "-TS2-" = tinned copper conductor with FT2 flame rating (standard). "-TS1-" = tinned copper conductor with VW-1 / FT1 flame rating (optional).