UL 3272

UL 3272 is a CASMO hook-up wire for UL AWM. XLPE insulated, -40°C to +125°C, 600V. UL3272 — 600 Vac, 125 °C XLPE hook-up wire for internal wiring of appliances and electronic equipment.

UL3272 — 600 Vac, 125 °C XLPE hook-up wire for internal wiring of appliances and electronic equipment.

Key Ratings

  • 3272: · Temperature -40°C to +125°C · Rated Voltage 600V

Construction

Conductor
Tinned Copper or Bare Copper
Insulation
Extruded · XLPE

Characteristics

  • Abrasion & Cut-Through Resistance: Tough cross-linked insulation with excellent resistance to abrasion, deformation, and cut-through.
  • Soldering Heat Resistance: Thermoset cross-linked insulation will not melt or flow at soldering temperatures.

Applications

  • Internal wiring: Internal wiring of appliances and electronic equipment.

Standards & Compliance

  • Standard: UL 758 AWM
  • Fire Performance: VW-1, FT1, FT2
  • RoHS: Compliant
  • REACH: Compliant

UL3272

CASMO Part No.Conductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Min. Ins. Thickness (mm)Nom. O.D. (mm)Max. DCR @20°C (Ω/km)Nom. Cable Weight (kg/km)
12113226/7-TS2-XX2670.160.480.760.692.11504.3
12113224/11-TS2-XX24110.160.610.760.692.2594.25.39
12113224/19-TS2-XX24190.1270.640.760.692.2594.25.54
12113222/7-TS2-XX2270.2540.760.760.692.359.46.6
12113222/17-TS2-XX22170.160.760.760.692.359.46.48
12113220/19-TS2-XX20190.210.760.692.5236.79.14
12113220/26-TS2-XX20260.160.940.760.692.5236.78.57
12113220/41-TS2-XX20410.1270.940.760.692.5236.78.54
12113218/19-TS2-XX18190.2541.270.760.692.7923.212.9
12113218/41-TS2-XX18410.161.180.760.692.7923.211.84
12113216/26-TS2-XX16260.2541.490.760.693.114.617.11
12113216/65-TS2-XX16650.161.50.760.693.114.616.99
12113214/41-TS2-XX14410.2541.880.760.693.58.9624.84
12113214/104-TS2-XX141040.161.890.760.693.58.9624.93
12113212/65-TS2-XX12650.2542.360.760.6945.6436.9
12113212/168-TS2-XX121680.162.370.760.6945.6437.61
12113210/105-TS2-XX101050.2542.980.760.694.803.5457.64
12113210/259-TS2-XX102590.162.970.760.694.803.5456.68
1211328/168-TS2-XX81680.2543.81.141.046.72.2396.84
1211328/420-TS2-XX84200.163.781.141.046.72.2397.42
1211326/266-TS2-XX62660.2544.751.141.047.61.4145.53
1211326/665-TS2-XX66650.164.751.141.047.61.4144.57
1211324/133-TS2-XX41330.455.981.141.049.10.9222.41
1211324/420-TS2-XX44200.2545.981.141.049.10.9223.56
1211324/1064-TS2-XX410640.165.981.141.049.10.9224.55

* Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. † "-TS2-" = tinned copper conductor with FT2 flame rating (standard). "-TS1-" = tinned copper conductor with VW-1 / FT1 flame rating (optional).

  • Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
  • "-TS2-" = tinned copper conductor with FT2 flame rating (standard). "-TS1-" = tinned copper conductor with VW-1 / FT1 flame rating (optional).

Related Categories