UL 1007 / 1569
UL 1007 / 1569 is a CASMO hook-up wire for UL AWM. PVC insulated, 1007: -20°C to +80°C / 1569: -20°C to +105°C, 1007: 300V / 1569: 300V.
Key Ratings
- 1007: · Temperature -20°C to +80°C · Rated Voltage 300V
- 1569: · Temperature -20°C to +105°C · Rated Voltage 300V
Construction
- Conductor
- Tinned Copper or Bare Copper
- Insulation
- Extruded · PVC
Characteristics
- Oil & Fluid Resistance: Good resistance to oils, greases, and common industrial fluids.
- Flexible: Flexible stranded construction for easy routing and installation in confined spaces.
Applications
- Internal wiring: Internal wiring of appliances and electronic equipment.
Standards & Compliance
- Standard: UL 758 AWM
- Fire Performance: VW-1, FT1
- RoHS: Compliant
- REACH: Compliant
UL1007_1569
| CASMO Part No. | Conductor Size (AWG) | No. Of Strands | Nom. Strand Dia. (mm) | Nom. Conductor Dia. (mm) | Nom. Ins. Thickness (mm) | Min. Ins. Thickness (mm) | Nom. O.D. (mm) | Max. DCR @20°C (Ω/km) | Nom. Cable Weight (kg/km) |
|---|---|---|---|---|---|---|---|---|---|
| 412630/7-TS-XX | 30 | 7 | 0.1 | 0.3 | 0.38 | 0.33 | 1.1 | 381 | 1.81 |
| 412628/7-TS-XX | 28 | 7 | 0.127 | 0.38 | 0.38 | 0.33 | 1.2 | 239 | 2.25 |
| 412626/7-TS-XX | 26 | 7 | 0.16 | 0.48 | 0.38 | 0.33 | 1.3 | 150 | 2.91 |
| 412624/11-TS-XX | 24 | 11 | 0.16 | 0.61 | 0.38 | 0.33 | 1.4 | 94.2 | 3.87 |
| 412624/19-TS-XX | 24 | 19 | 0.127 | 0.64 | 0.38 | 0.33 | 1.4 | 94.2 | 3.87 |
| 412622/7-TS-XX | 22 | 7 | 0.254 | 0.76 | 0.38 | 0.33 | 1.6 | 59.4 | 5.23 |
| 412622/17-TS-XX | 22 | 17 | 0.16 | 0.76 | 0.38 | 0.33 | 1.6 | 59.4 | 5.23 |
| 412620/19-TS-XX | 20 | 19 | 0.2 | 1 | 0.38 | 0.33 | 1.8 | 36.7 | 7.19 |
| 412620/26-TS-XX | 20 | 26 | 0.16 | 0.94 | 0.38 | 0.33 | 1.8 | 36.7 | 7.19 |
| 412620/41-TS-XX | 20 | 41 | 0.127 | 0.94 | 0.38 | 0.33 | 1.8 | 36.7 | 7.19 |
| 412618/19-TS-XX | 18 | 19 | 0.254 | 1.27 | 0.38 | 0.33 | 2.1 | 23.2 | 10.35 |
| 412618/41-TS-XX | 18 | 41 | 0.16 | 1.18 | 0.38 | 0.33 | 2.1 | 23.2 | 10.35 |
| 412616/26-TS-XX | 16 | 26 | 0.254 | 1.49 | 0.38 | 0.33 | 2.4 | 14.6 | 15.35 |
| 412616/65-TS-XX | 16 | 65 | 0.16 | 1.5 | 0.38 | 0.33 | 2.4 | 14.6 | 15.26 |
| 412614/41-TS-XX | 14 | 41 | 0.254 | 1.88 | 0.38 | 0.33 | 2.8 | 8.96 | 23.14 |
| 412614/104-TS-XX | 14 | 104 | 0.16 | 1.89 | 0.38 | 0.33 | 2.8 | 8.96 | 23.22 |
| 412612/65-TS-XX | 12 | 65 | 0.254 | 2.36 | 0.38 | 0.33 | 3.3 | 5.64 | 35.05 |
| 412612/168-TS-XX | 12 | 168 | 0.16 | 2.37 | 0.38 | 0.33 | 3.3 | 5.64 | 35.74 |
| 412610/105-TS-XX | 10 | 105 | 0.254 | 2.98 | 0.38 | 0.33 | 3.90 | 3.54 | 54.16 |
| 412610/259-TS-XX | 10 | 259 | 0.16 | 2.97 | 0.38 | 0.33 | 3.90 | 3.54 | 53.22 |
* -40°C versions are available on special request. † Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. ‡ "-TS-" = tinned copper conductor, "-AS-" = bare copper conductor; TS and AS may be substituted for each other. § UL 1007 covers up to 16 AWG; sizes 14 AWG to 10 AWG are covered under UL 1569 only.
- -40°C versions are available on special request.
- Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
- "-TS-" = tinned copper conductor, "-AS-" = bare copper conductor; TS and AS may be substituted for each other.
- UL 1007 covers up to 16 AWG; sizes 14 AWG to 10 AWG are covered under UL 1569 only.