UL 1007 / 1569

UL 1007 / 1569 is a CASMO hook-up wire for UL AWM. PVC insulated, 1007: -20°C to +80°C / 1569: -20°C to +105°C, 1007: 300V / 1569: 300V.

Key Ratings

  • 1007: · Temperature -20°C to +80°C · Rated Voltage 300V
  • 1569: · Temperature -20°C to +105°C · Rated Voltage 300V

Construction

Conductor
Tinned Copper or Bare Copper
Insulation
Extruded · PVC

Characteristics

  • Oil & Fluid Resistance: Good resistance to oils, greases, and common industrial fluids.
  • Flexible: Flexible stranded construction for easy routing and installation in confined spaces.

Applications

  • Internal wiring: Internal wiring of appliances and electronic equipment.

Standards & Compliance

  • Standard: UL 758 AWM
  • Fire Performance: VW-1, FT1
  • RoHS: Compliant
  • REACH: Compliant

UL1007_1569

CASMO Part No.Conductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Min. Ins. Thickness (mm)Nom. O.D. (mm)Max. DCR @20°C (Ω/km)Nom. Cable Weight (kg/km)
412630/7-TS-XX3070.10.30.380.331.13811.81
412628/7-TS-XX2870.1270.380.380.331.22392.25
412626/7-TS-XX2670.160.480.380.331.31502.91
412624/11-TS-XX24110.160.610.380.331.494.23.87
412624/19-TS-XX24190.1270.640.380.331.494.23.87
412622/7-TS-XX2270.2540.760.380.331.659.45.23
412622/17-TS-XX22170.160.760.380.331.659.45.23
412620/19-TS-XX20190.210.380.331.836.77.19
412620/26-TS-XX20260.160.940.380.331.836.77.19
412620/41-TS-XX20410.1270.940.380.331.836.77.19
412618/19-TS-XX18190.2541.270.380.332.123.210.35
412618/41-TS-XX18410.161.180.380.332.123.210.35
412616/26-TS-XX16260.2541.490.380.332.414.615.35
412616/65-TS-XX16650.161.50.380.332.414.615.26
412614/41-TS-XX14410.2541.880.380.332.88.9623.14
412614/104-TS-XX141040.161.890.380.332.88.9623.22
412612/65-TS-XX12650.2542.360.380.333.35.6435.05
412612/168-TS-XX121680.162.370.380.333.35.6435.74
412610/105-TS-XX101050.2542.980.380.333.903.5454.16
412610/259-TS-XX102590.162.970.380.333.903.5453.22

* -40°C versions are available on special request. † Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. ‡ "-TS-" = tinned copper conductor, "-AS-" = bare copper conductor; TS and AS may be substituted for each other. § UL 1007 covers up to 16 AWG; sizes 14 AWG to 10 AWG are covered under UL 1569 only.

  • -40°C versions are available on special request.
  • Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
  • "-TS-" = tinned copper conductor, "-AS-" = bare copper conductor; TS and AS may be substituted for each other.
  • UL 1007 covers up to 16 AWG; sizes 14 AWG to 10 AWG are covered under UL 1569 only.