UL 3271

UL 3271 is a CASMO hook-up wire for UL AWM. XLPE insulated, -40°C to +125°C, 600V.

Key Ratings

  • 3271: · Temperature -40°C to +125°C · Rated Voltage 600V

Construction

Conductor
Tinned Copper or Bare Copper
Insulation
Extruded · XLPE

Characteristics

  • Abrasion & Cut-Through Resistance: Tough cross-linked insulation with excellent resistance to abrasion, deformation, and cut-through.
  • Soldering Heat Resistance: Thermoset cross-linked insulation will not melt or flow at soldering temperatures.

Applications

  • Internal wiring: Internal wiring of appliances and electronic equipment.

Standards & Compliance

  • Standard: UL 758 AWM
  • Fire Performance: VW-1, FT1, FT2
  • RoHS: Compliant
  • REACH: Compliant

UL3271

CASMO Part No.Conductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Min. Ins. Thickness (mm)Nom. O.D. (mm)Max. DCR @20°C (Ω/km)Nom. Cable Weight (kg/km)
410630/7-TS2-XX3070.10.30.760.691.93813.06
410628/7-TS2-XX2870.1270.380.760.6922393.6
410626/7-TS2-XX2670.160.480.760.692.11504.3
410624/11-TS2-XX24110.160.610.760.692.294.25.23
410624/19-TS2-XX24190.1270.640.760.692.294.25.38
410622/7-TS2-XX2270.2540.760.760.692.459.46.94
410622/17-TS2-XX22170.160.760.760.692.459.46.82
410620/19-TS2-XX20190.210.760.692.636.79.51
410620/26-TS2-XX20260.160.940.760.692.636.78.94
410620/41-TS2-XX20410.1270.940.760.692.636.78.91
410618/19-TS2-XX18190.2541.270.760.692.823.213.11
410618/41-TS2-XX18410.161.180.760.692.823.212.04
410616/26-TS2-XX16260.2541.490.760.693.114.617.11
410616/65-TS2-XX16650.161.50.760.693.114.616.99
410614/41-TS2-XX14410.2541.880.760.693.58.9624.84
410614/104-TS2-XX141040.161.890.760.693.58.9624.93
410612/65-TS2-XX12650.2542.360.760.6945.6436.9
410612/168-TS2-XX121680.162.370.760.6945.6437.61
410610/105-TS2-XX101050.2542.980.760.694.73.5454.89
410610/259-TS2-XX102590.162.970.760.694.73.5455.99
41068/168-TS2-XX81680.2543.81.141.026.52.2394.91
41068/420-TS2-XX84200.163.781.141.026.52.2395.5
41066/266-TS2-XX62660.2544.751.141.027.71.4146.65
41066/665-TS2-XX66650.164.751.141.027.71.4145.69
41064/133-TS2-XX41330.455.981.141.029.10.9222.41
41064/420-TS2-XX44200.2545.981.141.029.10.9223.56
41064/1064-TS2-XX410640.165.981.141.029.10.9224.55
41062/665-TS2-XX26650.2548.101.141.0211.10.56336.9
41062/1665-TS2-XX216650.168.101.141.0211.10.56334.96

Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. "-TS2-" = tinned copper conductor with FT2 flame rating (standard). "-TS1-" = tinned copper conductor with VW-1 / FT1 flame rating (optional).

  • Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
  • "-TS2-" = tinned copper conductor with FT2 flame rating (standard). "-TS1-" = tinned copper conductor with VW-1 / FT1 flame rating (optional).