UL 1284
UL 1284 is a CASMO hook-up wire for UL AWM. PVC insulated, -20°C to +105°C, 600V. UL1284 — 600 Vac, 105 °C PVC hook-up wire for internal wiring of appliances and electronic equipment.
UL1284 — 600 Vac, 105 °C PVC hook-up wire for internal wiring of appliances and electronic equipment.
Key Ratings
- 1284: · Temperature -20°C to +105°C · Rated Voltage 600V
Construction
- Conductor
- Bare copper or Tin-plated copper
- Insulation
- Extruded · PVC
Characteristics
- Oil & Fluid Resistance: Good resistance to oils, greases, and common industrial fluids.
- Flexible: Flexible stranded construction for easy routing and installation in confined spaces.
Applications
- Internal wiring: Internal wiring of appliances and electronic equipment.
Standards & Compliance
- Standard: UL 758 AWM
- Fire Performance: VW-1, FT1
- RoHS: Compliant
- REACH: Compliant
UL1284
| CASMO Part No. | Conductor Size (AWG) | No. Of Strands | Nom. Strand Dia. (mm) | Nom. Conductor Dia. (mm) | Nom. Ins. Thickness (mm) | Min. Ins. Thickness (mm) | Nom. O.D. (mm) | Max. DCR @20°C (Ω/km) | Nom. Cable Weight (kg/km) |
|---|---|---|---|---|---|---|---|---|---|
| 41258/168-TS-XX | 8 | 168 | 0.254 | 3.8 | 2.03 | 1.83 | 8.20 | 2.23 | 132.91 |
| 41258/420-TS-XX | 8 | 420 | 0.16 | 3.78 | 2.03 | 1.83 | 8.20 | 2.23 | 132.46 |
| 41256/266-TS-XX | 6 | 266 | 0.254 | 4.75 | 2.03 | 1.83 | 9.50 | 1.4 | 193.19 |
| 41256/665-TS-XX | 6 | 665 | 0.16 | 4.75 | 2.03 | 1.83 | 9.50 | 1.4 | 192.23 |
| 41254/133-TS-XX | 4 | 133 | 0.45 | 5.98 | 2.03 | 1.83 | 11.00 | 0.9 | 280.43 |
| 41254/420-TS-XX | 4 | 420 | 0.254 | 5.98 | 2.03 | 1.83 | 11.00 | 0.9 | 281.58 |
| 41254/1064-TS-XX | 4 | 1064 | 0.16 | 5.98 | 2.03 | 1.83 | 11.00 | 0.9 | 282.57 |
| 41252/665-TS-XX | 2 | 665 | 0.254 | 8.10 | 2.03 | 1.83 | 13.00 | 0.56 | 411.62 |
| 41252/1665-TS-XX | 2 | 1665 | 0.16 | 8.10 | 2.03 | 1.83 | 13.00 | 0.56 | 409.67 |
* -40°C versions are available on special request. † Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. ‡ "-TS-" = tinned copper conductor, "-AS-" = bare copper conductor; TS and AS may be substituted for each other.
- -40°C versions are available on special request.
- Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
- "-TS-" = tinned copper conductor, "-AS-" = bare copper conductor; TS and AS may be substituted for each other.