FLR2X150

FLR2X150 is a CASMO automotive wire for ISO/DIN Automotive. XLPE insulated, 150°C, 25/60V. FLR2X150 automotive cable per ISO 19642-3, rated 150°C and 25V AC / 60V DC.

FLR2X150 automotive cable per ISO 19642-3, rated 150°C and 25V AC / 60V DC.

Key Ratings

  • FLR2X150: · Temperature 150°C · Rated Voltage 25/60V

Construction

Conductor
Flexible Bare Copper or Flexible Tinned Copper
Insulation
Extruded · XLPE

Characteristics

  • Heat Stability: Holds its dimensions after heat exposure, with minimal shrinkage at the cable ends.
  • Abrasion Resistance: Withstands abrasion and chafing in harness routing.

Applications

  • Automotive Low-Voltage Circuits: Heat-resistant thin-wall primary wiring for low-voltage automotive circuits.

Standards & Compliance

  • Standard: ISO 19642-3
  • RoHS: Compliant
  • REACH: Compliant

FLR2X150-A

CASMO Part No.Conductor Size (mm²)No. Of StrandsMax. Strand Dia. (mm)Max. Conductor Dia. (mm)Min. Ins. Thickness (mm)Max. Overall O.D. (mm)Max. DCR BC @20°C (Ω/km)Max. DCR TPC @20°C (Ω/km)Nom. Cable Weight (kg/km)
1150340.22/7-**-XX0.2270.210.700.201.2084.886.52.8
1150340.35/7-**-XX0.3570.260.800.201.3054.455.54.0
1150340.5/19-**-XX0.5190.191.000.221.6037.138.26.5
1150340.75/19-**-XX0.75190.241.200.241.9024.725.48.6
1150341/19-**-XX1190.261.350.242.1018.519.111.1
1150341.5/19-**-XX1.5190.321.700.242.4012.71315.9
1150342.5/19-**-XX2.5190.412.200.283.007.67.8226.0

† Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. ‡ Replace ** with the conductor code: AS for bare copper or TS for tinned copper.

  • Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
  • Replace ** with the conductor code: AS for bare copper or TS for tinned copper.

FLR2X150-B

CASMO Part No.Conductor Size (mm²)No. Of StrandsMax. Strand Dia. (mm)Max. Conductor Dia. (mm)Min. Ins. Thickness (mm)Max. Overall O.D. (mm)Max. DCR BC @20°C (Ω/km)Max. DCR TPC @20°C (Ω/km)Nom. Cable Weight (kg/km)
1150340.35/12-**-XX0.35120.210.900.201.4054.455.54.8
1150340.5/16-**-XX0.5160.211.000.221.6037.138.25.8
1150340.75/24-**-XX0.75240.211.200.241.9024.725.49.8
1150341/32-**-XX1320.211.350.242.1018.519.113.2
1150341.5/30-**-XX1.5300.261.700.242.4012.71317.0
1150342/28-**-XX2280.312.000.282.809.429.6921.4
1150342.5/50-**-XX2.5500.262.200.283.007.67.8229.9
1150343/44-**-XX3440.312.400.323.406.156.3631.9
1150344/56-**-XX4560.312.750.323.704.714.8541.0
1150345/65-**-XX5650.323.250.324.203.944.0251.7
1150346/84-**-XX6840.313.300.324.303.143.2359.8
1150348/100-**-XX81000.334.300.325.002.382.5280.0
11503410/80-**-XX10800.414.500.486.001.821.85104.0
11503416/126-**-XX161260.415.800.527.201.161.18161.6
11503425/196-**-XX251960.417.200.528.700.7430.757248.0

† Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. ‡ Replace ** with the conductor code: AS for bare copper or TS for tinned copper.

  • Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear.
  • Replace ** with the conductor code: AS for bare copper or TS for tinned copper.