Wire Size Conversion Calculator

Convert AWG 44 to 4/0 AWG, CMIL/kcmil (up to 800 kcmil reference), metric mm² (0.002 to 400 mm²), solid diameter (mm/in), square inches, and nominal copper weight with CAD cross-section and vernier scale.

Wire Size Converter Capabilities

  • 6 simultaneously editable suffix-unit fields (AWG, CMIL/kcmil, mm², mm Ø, in², in Ø)
  • ASTM B258 (44 AWG to 4/0 AWG, 250–800 kcmil reference) and IEC 60228 / ISO 19642 / JASO metric matching
  • Interactive CAD cross-section comparison with nominal solid copper weight (kg/km & lbs/kft)
  • Zoomed logarithmic vernier scale and on-demand ASTM / IEC lookup chart

Nominal Solid Copper Weight Formula

Nominal solid annealed copper conductor weight is calculated using standard ASTM B3 / IEC 60228 copper density (8.89 g/cm³): Solid Weight (kg/km) = Cross-Sectional Area (mm²) × 8.89, and Solid Weight (lbs/1,000 ft) = kg/km × 0.672. Stranded copper conductors add approximately 2% for helical lay length (conductor mass only; excludes insulation or jacket).

ASTM B258 AWG Reference Table (44 AWG to 4/0 AWG)

AWG SizeArea (mm²)Solid Diameter (mm)Solid Diameter (in)Area (in²)Circular Mils (cmil)Nominal Solid Cu Weight (kg/km)
44 AWG0.001980.05020.00200.00000313.90.0176
43 AWG0.002500.05640.00220.00000394.90.0222
42 AWG0.003150.06330.00250.00000496.20.0280
41 AWG0.003970.07110.00280.00000627.80.0353
40 AWG0.005010.07990.00310.00000789.90.0445
39 AWG0.006320.08970.00350.000009812.50.0562
38 AWG0.007970.1010.00400.000012315.70.0708
37 AWG0.01000.1130.00450.000015619.80.0893
36 AWG0.01270.1270.00500.000019625.00.11
35 AWG0.01600.1430.00560.000024831.50.14
34 AWG0.02010.1600.00630.000031239.80.18
33 AWG0.02540.1800.00710.000039450.10.23
32 AWG0.03200.2020.00800.000049663.20.28
31 AWG0.04040.2270.00890.000062679.70.36
30 AWG0.05090.2550.01000.00007891010.45
29 AWG0.06420.2860.01130.00009951270.57
28 AWG0.08100.3210.01260.0001261600.72
27 AWG0.10210.3610.01420.0001582020.91
26 AWG0.12880.4050.01590.0002002541.14
25 AWG0.16240.4550.01790.0002523201.44
24 AWG0.20470.5110.02010.0003174041.82
23 AWG0.25820.5730.02260.0004005092.30
22 AWG0.32550.6440.02530.0005056422.89
21 AWG0.41050.7230.02850.0006368103.65
20 AWG0.51760.8120.03200.00080210224.60
19 AWG0.65270.9120.03590.00101212885.80
18 AWG0.82301.0240.04030.00127616247.32
17 AWG1.0381.1500.04530.00160920489.23
16 AWG1.3091.2910.05080.002028258311.6
15 AWG1.6501.4500.05710.002558325714.7
14 AWG2.0811.6280.06410.003225410718.5
13 AWG2.6241.8280.07200.004067517823.3
12 AWG3.3092.0530.08080.005129653029.4
11 AWG4.1722.3050.09070.006467823437.1
10 AWG5.2612.5880.10190.0081551038346.8
9 AWG6.6342.9060.11440.01031309359.0
8 AWG8.3663.2640.12850.01301651074.4
7 AWG10.553.6650.14430.01642081893.8
6 AWG13.304.1150.16200.020626251118.3
5 AWG16.774.6210.18190.026033102149.1
4 AWG21.155.1890.20430.032841741188.0
3 AWG26.675.8270.22940.041352635237.1
2 AWG33.636.5440.25760.052166371299.0
1 AWG42.417.3480.28930.065783693377.0
1/0 AWG53.488.2510.32490.0829105535475.4
2/0 AWG67.439.2660.36480.1045133077599.5
3/0 AWG85.0310.4050.40960.1318167806755.9
4/0 AWG107.2211.6840.46000.1662211600953.2

Standard kcmil Reference Table (250 kcmil to 800 kcmil)

SizeArea (mm²)Solid Diameter (mm)Solid Diameter (in)Nominal Solid Cu Weight (kg/km)Notes
250 kcmil126.6812.700.50001126.2Within CASMO standard manufacturing envelope
300 kcmil152.0113.910.54771351.4Within CASMO standard manufacturing envelope
350 kcmil177.3515.030.59161576.6Within CASMO standard manufacturing envelope
400 kcmil202.6816.060.63251801.9Within CASMO standard manufacturing envelope
500 kcmil253.3517.960.70712252.3Within CASMO standard manufacturing envelope
600 kcmil304.0219.670.77462702.8Within CASMO standard manufacturing envelope
700 kcmil354.7021.250.83673153.2Within CASMO standard manufacturing envelope
750 kcmil380.0322.000.86603378.5Within CASMO standard manufacturing envelope
800 kcmil405.3722.720.89443603.7Reference only for 400 mm² (789.4 kcmil) next-larger conversion; CASMO standard manufacturing capability covers AWG 44 to 750 kcmil and 0.002 mm² to 400 mm².

Metric Wire Size Reference Table (0.002 mm² to 400 mm²)

Metric SizeStandard SeriesSolid Diameter (mm)Equivalent kcmilNominal Solid Cu Weight (kg/km)
0.002 mm²Micro AWG 44 equiv.0.05050.00390.0178
0.005 mm²Micro AWG 40 equiv.0.07980.00990.0445
0.01 mm²Micro AWG 37 equiv.0.1130.01970.0889
0.02 mm²Micro AWG 34 equiv.0.1600.03950.18
0.03 mm²Micro AWG 32 equiv.0.1950.05920.27
0.05 mm²DIN VDE 0812 / AWG 300.2520.09870.44
0.08 mm²DIN VDE 0812 / AWG 280.3190.15790.71
0.09 mm²DIN VDE 08120.3390.17760.80
0.13 mm²ISO 196420.4070.25661.16
0.14 mm²DIN VDE 08120.4220.27631.24
0.22 mm²ISO 19642 / DIN VDE 08120.5290.43421.96
0.25 mm²DIN VDE 08120.5640.49342.22
0.3 mm²JASO D611 (0.3 / 0.3f)0.6180.59212.67
0.34 mm²DIN VDE 08120.6580.67103.02
0.35 mm²ISO 196420.6680.69073.11
0.5 mm²IEC 60228 / ISO 19642 / JASO0.7980.98684.45
0.75 mm²IEC 60228 / ISO 196420.9771.486.67
0.85 mm²JASO D6111.0401.687.56
1 mm²IEC 60228 / ISO 196421.1281.978.89
1.25 mm²JASO D6111.2622.4711.1
1.5 mm²IEC 60228 / ISO 196421.3822.9613.3
2 mm²JASO / ISO 196421.5963.9517.8
2.5 mm²IEC 60228 / ISO 196421.7844.9322.2
3 mm²JASO / ISO 196421.9545.9226.7
4 mm²IEC 60228 / ISO 196422.2577.8935.6
5 mm²JASO D6112.5239.8744.5
6 mm²IEC 60228 / ISO 196422.76411.8453.3
8 mm²JASO D6113.19215.7971.1
10 mm²IEC 60228 / ISO 196423.56819.7488.9
15 mm²JASO D6114.37029.60133.4
16 mm²IEC 60228 / ISO 196424.51431.58142.2
20 mm²JASO D6115.04639.47177.8
25 mm²IEC 60228 / ISO 196425.64249.34222.3
30 mm²JASO D6116.18059.21266.7
35 mm²IEC 60228 / ISO 196426.67669.07311.2
40 mm²JASO D6117.13678.94355.6
50 mm²IEC 60228 / ISO 196427.97998.68444.5
60 mm²JASO D6118.740118.41533.4
70 mm²IEC 60228 / ISO 196429.441138.15622.3
95 mm²IEC 60228 / ISO 1964210.998187.48844.6
120 mm²IEC 60228 / ISO 1964212.361236.821066.8
150 mm²IEC 6022813.820296.031333.5
185 mm²IEC 6022815.348365.101644.7
240 mm²IEC 6022817.481473.652133.6
300 mm²IEC 6022819.544592.062667.0
400 mm²IEC 60228 (CASMO Max)22.568789.413556.0

Engineering Notice & Disclaimer

These online engineering calculators are provided by CASMO CABLE LLC for preliminary estimation and general reference only, on an "as-is" basis without warranty of any kind. Outputs are derived from nominal geometric cross-sections and standard material models and do not account for AC skin or proximity effects, connector contact resistance, ampacity derating, or installation thermal limits. Before finalizing any specification, safety-critical or regulated end-use qualification, or production order, engineers must verify guaranteed electrical and dimensional limits against CASMO's published specification sheets, approved engineering drawings, and physical sample testing. CASMO CABLE LLC assumes no liability for design decisions or indirect or consequential damages arising from use of these tools. See Terms and Conditions of Sale (Section 10) for full legal terms.

Frequently Asked Questions

Why does 400 mm² map to 800 kcmil instead of 750 kcmil as the next larger imperial size?
750 kcmil equals 380.03 mm², which is roughly 5% smaller than a 400 mm² metric conductor (789.4 kcmil). To avoid undersizing ampacity or voltage drop when crossing from 400 mm² to imperial sizes, the next standard NEC/ASTM size up is 800 kcmil (405.37 mm²). CASMO's manufacturing capability covers AWG 44 to 750 kcmil and 0.002 mm² to 400 mm² metric.
Why does 2.5 mm² show 13 AWG as next larger and 12 AWG as next even stock gauge?
By exact ASTM B258 geometry, 2.5 mm² corresponds to continuous gauge 13.21 AWG: 14 AWG (2.08 mm²) is smaller, 13 AWG (2.62 mm²) is the closest and next larger ASTM gauge, while 12 AWG (3.31 mm²) is the next larger common even stock gauge typically carried on UL hook-up and power wire reels.
Are the diameter fields solid or stranded conductor diameters?
The coupled mm Ø and in Ø inputs represent nominal solid circular diameter (d = √(4A/π)) per ASTM B258 so all six fields remain an exact reversible bijection. Because stranded conductors include interstitial air space between strands, an equivalent-area stranded bundle has a larger nominal O.D. (typically ~1.13× for 7-strand and ~1.15× for 19-strand concentric stranding), shown in the read-only estimate bar.
How is nominal solid copper weight calculated?
Using the standard ASTM B3 / IEC 60228 annealed copper density of 8.89 g/cm³, solid copper weight equals Area (mm²) × 8.89 kg/km (or × 0.672 for lbs/1,000 ft). Stranded conductors add approximately 2% for helical lay length, excluding insulation or jacket mass.