4GKW-AX PLUS FLEX

4GKW-AX PLUS FLEX is a CASMO control & data cable for Control & Data Cable. Halogen-Free XLPO insulated, -40°C to +120°C, 1800/3000V. 4GKW-AX Plus Flex extra-flexible halogen-free cross-linked railway rolling stock power and control cable, 1.8/3 kV, -40°C to +120°C.

4GKW-AX Plus Flex extra-flexible halogen-free cross-linked railway rolling stock power and control cable, 1.8/3 kV, -40°C to +120°C.

Key Ratings

  • 4GKW-AX PLUS FLEX: · Temperature -40°C to +120°C · Rated Voltage 1800/3000V · Test Voltage 6500V / 5 min (AC 50 Hz)

Construction

Conductor
Flexible Tinned Copper · Extra-Flexible Stranded
Insulation
Extruded · Halogen-Free XLPO
Jacket
Extruded · Halogen-Free XLPO

Characteristics

  • Max. Short-Circuit Temperature: +250°C (5 s)
  • Nominal Voltage U0/U (Um): 1.8/3 kV AC (Um 3.6 kV)
  • Flexibility: Flexible construction facilitates routing, bending and installation where space is limited.
  • Fluid & Chemical Inertness: Resists fuels, lubricants, hydraulic fluids, oils, acids, alkalis, and industrial solvents.
  • Dual-Wall Visual Inspection: Contrasting inner and outer cross-linked layers provide instant visual indication of mechanical scrape or wear.

Applications

  • Railway Rolling Stock Power & Control: Onboard safety circuits, lighting circuits, auxiliary power distribution, traction converters, and switchgear cabinets in railway vehicles.

Standards & Compliance

  • Standard: EN 50264-3-1 / EN 45545-2
  • Fire Performance: Fire Retardant: EN 60332-1-2 / IEC 60332-1-2 · EN 50305 · EN 50266-2-4
  • RoHS: Compliant
  • REACH: Compliant

4GKW-AX PLUS FLEX

CASMO Part No.Conductor Size (mm²)No. Of StrandsNom. Strand Dia. (mm)Nom. Wall Thickness (mm)Min. Wall Thickness (mm)Nom. O.D. (mm)O.D. Tolerance ± (mm)Max. DCR @20°C (Ω/km)Nom. Cable Weight (kg/km)
1120051X1320.200.70.532.800.42017
1120051-5X1.5300.250.70.533.200.413.723
1120052-5X2.5490.250.70.533.700.48.2135
1120054X4560.300.80.624.450.45.0953
1120056X6840.300.80.625.050.43.3976
11200510X103150.200.80.626.100.61.95122
11200516X164900.200.90.717.800.61.24187
11200525X257790.201.20.989.600.60.795283
11200535X3510450.201.41.1611.400.60.565396
11200550X509690.251.41.1613.400.60.393560
11200570X7013550.251.61.3414.901.00.277750
11200595X9518500.251.61.3416.901.00.21980
112005120X12023310.251.81.5219.201.00.1641234
112005150X15029600.252.01.7021.002.00.1321550
112005185X18537000.252.01.7022.802.00.1081860
112005240X24048000.252.01.7026.102.00.08172500
112005300X30041440.302.01.7029.102.00.06543150
112005400X40054390.302.01.7032.502.00.04953900

* Suffix "X" denotes the Extra-Flexible conductor version. Standard inner core insulation is White; standard outer sheath is Black (other sheath colours available upon request). † Wall thickness values represent combined dual-layer insulation and sheath thickness. Cross-sections 70 mm² to 400 mm² incorporate a non-woven separator tape over the conductor.