AV

AV is a CASMO automotive wire for JASO Automotive. PVC insulated, 80°C, 25/60V.

Key Ratings

  • AV: · Temperature 80°C · Rated Voltage 25/60V

Construction

Conductor
Bare Copper or Tinned Copper
Insulation
Extruded · PVC

Characteristics

  • Fluid Resistance: Resists gasoline, diesel and engine oil in vehicle service.
  • Abrasion Resistance: Withstands abrasion and chafing in harness routing.

Applications

  • Automotive Low-Voltage Circuits: General-purpose primary wiring for low-voltage automotive circuits.

Standards & Compliance

  • Standard: JASO D611

AV

CASMO Part No.Conductor Size (mm²)No. Of StrandsMax. Strand Dia. (mm)Max. Conductor Dia. (mm)Min. Ins. Thickness (mm)Max. Overall O.D. (mm)Max. DCR @20°C (Ω/km)
1130012f/37-**-XX2f370.261.80.483.49.5
1130013f/58-**-XX3f580.262.30.564.06.06
1130013f/61-**-XX3f610.262.40.564.15.76
1130015f/63-**-XX5f630.323.10.645.03.71
1130015f/210-**-XX5f2100.183.40.645.33.56
1130018f/154-**-XX8f1540.264.20.726.32.32
1130019f/112-**-XX9f1120.324.20.86.52.09
11300110f/114-**-XX10f1140.324.20.86.52.05
11300110/62-**-XX10620.454.10.726.21.87
11300110/63-**-XX10630.454.50.86.91.84
11300115f/171-**-XX15f1710.325.30.888.01.37
11300120f/247-**-XX20f2470.326.50.889.30.946
11300130f/361-**-XX30f3610.327.81.1211.30.647
11300140f/494-**-XX40f4940.329.11.1212.60.473
11300150f/608-**-XX50f6080.3210.11.2814.10.384
11300160f/741-**-XX60f7410.3211.11.2815.10.315
11300185f/1064-**-XX85f10640.3213.11.618.10.22
113001100f/1349-**-XX100f13490.3214.91.619.90.173

† Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. ‡ Replace ** with the conductor code: AS for bare copper or TS for tinned copper. * Nominal size is the JASO designation; the suffix "f" denotes a flexible conductor.

  • † Part No. code: XX = colour code — BK Black, WH White, RD Red, GN Green, BN Brown, BL Blue, OR Orange, YW Yellow, VT Violet, GY Grey, PK Pink, TN Tan, CL Clear. ‡ Replace ** with the conductor code: AS for bare copper or TS for tinned copper.
  • Nominal size is the JASO designation; the suffix "f" denotes a flexible conductor.