H1Z2Z2-K

H1Z2Z2-K is a CASMO solar cable for Solar / PV. Halogen-Free XLPO insulated, -40°C to +90°C, 1000/1500V. TÜV Rheinland certified H1Z2Z2-K halogen-free cross-linked solar PV cable per EN 50618:2014, rated 1.0/1.0 kV AC and 1.5 kV DC (max. 1.8 kV DC) from -40°C to +90°C (+120°C conductor max.).

TÜV Rheinland certified H1Z2Z2-K halogen-free cross-linked solar PV cable per EN 50618:2014, rated 1.0/1.0 kV AC and 1.5 kV DC (max. 1.8 kV DC) from -40°C to +90°C (+120°C conductor max.).

Key Ratings

  • H1Z2Z2-K: · Temperature -40°C to +90°C · Rated Voltage 1000/1500V · Test Voltage 6500V / 5 min (AC Voltage Test (50Hz, 5 min water bath) per EN 50618)

Construction

Conductor
Flexible Tinned Copper · Class 5 (EN 60228 / IEC 60228)
Insulation
Extruded · Halogen-Free XLPO
Jacket
Extruded · Flame-Retardant XLPO
Outer Sheath Colour
Black or Red (other colours available on request)

Characteristics

  • Max. Conductor Temperature: +120°C (max. 20,000h at 50% residual elongation per EN 50618)
  • Min. Installation & Short-Circuit Temp.: -25°C min. installation · +250°C max. short-circuit (5 s)
  • Max. Permitted DC Voltage: 1800V DC (conductor-conductor, non-earthed system, circuit not under load)
  • UV, Ozone & Weather Resistance: Cross-linked sheath stands up to UV radiation, ozone, and long-term outdoor weathering.
  • Moisture & Water Resistance: Engineered for permanent outdoor exposure and wet service environments (AD8).
  • Flexible Routing: Fine-stranded tinned copper conductor bends easily through solar module arrays and inverter enclosures.

Applications

  • PV Module & String Interconnections: For stationary or freely suspended indoor and outdoor cabling between solar modules and between module strings and DC/AC inverters per HD 60364-7-712 and EN 50618.
  • Conduit, Duct & Class II Installations: Suitable for installation inside electrical pipes, ducts, channels, under plaster, and within Class II double-insulated appliances and PV systems up to 1800 V DC to ground.

Standards & Compliance

  • Standard: EN 50618
  • Fire Performance: Fire Retardant: IEC 60332-1-2
  • RoHS: Compliant
  • REACH: Compliant

H1Z2Z2-K

CASMO Part No.Conductor Size (mm²)Nom. Ins. Thickness (mm)Nom. Jkt. Thickness (mm)Nom. O.D. (mm)Max. DCR @20°C (Ω/km)Single Cable In Air (A)Single Cable On Surface (A)Two Cables Adjacent On Surface (A)Nom. Cable Weight (kg/km)
820011.5-XX1.50.70.84.613.730292436
820012.5-XX2.50.70.85.08.2141393346
820014-XX40.70.85.65.0955524462
820016-XX60.70.86.13.3970675782
8200110-XX100.70.87.11.95989379125
8200116-XX160.70.98.51.24132125107190
8200125-XX250.91.010.40.795176167142285
8200135-XX350.91.111.50.565218207176385
8200150-XX501.01.213.70.393276262221540
8200170-XX701.11.215.80.277347330278740
8200195-XX951.11.317.30.210416395333965
82001120-XX1201.21.319.10.1644884643901210
82001150-XX1501.41.421.40.1325665384531495
82001185-XX1851.61.624.90.1086446125151885
82001240-XX2401.71.727.30.0827757366202395

1 Current carrying capacity (ampacity) values per EN 50618 Annex A (Table A.3) at 60°C ambient temperature and 120°C max. conductor operating temperature.

  • Current carrying capacity (ampacity) values per EN 50618 Annex A (Table A.3) at 60°C ambient temperature and 120°C max. conductor operating temperature.