EN 50618 — European Photovoltaic DC System Cables
Harmonised 1.5 kV DC solar cable standard defining double-insulated, halogen-free, UV- and weather-resistant H1Z2Z2-K cable engineered for 25-year utility and rooftop PV installations.
Standard · CENELEC (European Committee for Electrotechnical Standardization)
What is EN 50618?
EN 50618 establishes the European harmonised standard for single-core photovoltaic DC cables designated H1Z2Z2-K (superseding legacy TÜV 2 PfG 1169 PV1-F). Engineered for at least 25 years of outdoor exposure, EN 50618 specifies finely stranded tinned-copper conductors wrapped in halogen-free, electron-beam cross-linked polyolefin (XLPO) insulation and outer sheath.
Compared with earlier 1.0 kV PV1-F cables, EN 50618 raises continuous DC ratings to 1.5 kV DC (1.8 kV max DC) while enforcing rigorous damp-heat, ozone, UV, cold-impact and IEC 60332-1-2 flame tests for modern 1500V string inverters and solar farms.
Designed for double-insulated Protection Class II photovoltaic systems (suitable for exposed outdoor routing without metallic conduit), EN 50618 mandates a minimum 25-year design life backed by a +120°C 20,000-hour thermal-endurance temperature index (EN 60216), +250°C short-circuit withstand (5 s) and 1.8 kV DC hot-water wet-insulation testing (240 h at +85°C). Its international IEC counterpart is IEC 62930 (62930 IEC 131), whereas North American NEC Article 690 projects specify AWG-sized UL 4703 PV Wire.
CASMO holds TÜV Rheinland Certificate R 50693675 for EN 50618 H1Z2Z2-K solar photovoltaic cables covering 1.5 mm² to 35 mm² conductors at 1500V DC (−40°C to +90°C ambient, +120°C max conductor), with downloadable certification documentation available on our Quality & Compliance page.
Key Technical Requirements
| Parameter | Requirement | Notes |
|---|---|---|
| Voltage rating | 1.5 kV DC (1.8 kV max DC) | 1.0/1.0 kV AC nominal |
| Construction | Tinned copper + dual-layer XLPO | Halogen-free & electron-beam cross-linked |
| Temperature | −40°C to +90°C ambient (+120°C cond.) | 25-year thermal endurance index |
| Weather & Fire | UV/ozone resistant · IEC 60332-1-2 | IEC 60754 halogen-free, IEC 61034 low smoke |
| Short-circuit & Life | +250°C (5 s) · TI +120°C (20,000 h) | Protection Class II double-insulated design |
| CASMO Certification | TÜV Rheinland Cert. R 50693675 | H1Z2Z2-K (1.5–35 mm², 1500V DC, −40°C to +90°C ambient) |
EN 50618 Products
- H1Z2Z2-K — EN 50618 · Halogen-Free XLPO · -40°C to +90°C · 1000/1500V
Insulation Materials in This Standard
Frequently Asked Questions
- What does the designation H1Z2Z2-K mean?
- H = Harmonised European standard, 1 = 1.5 kV DC PV rating, Z2 = cross-linked halogen-free insulation, Z2 = cross-linked halogen-free sheath, K = flexible Class 5 tinned-copper conductor.
- Can EN 50618 H1Z2Z2-K replace older PV1-F cable?
- Yes — H1Z2Z2-K meets and supersedes legacy 1.0 kV PV1-F specifications while qualifying for modern 1500V DC photovoltaic arrays.
- How does EN 50618 compare to IEC 62930 and North American UL 4703 PV Wire?
- EN 50618 is the European CENELEC standard (designating H1Z2Z2-K) and aligns closely in electrical, thermal and material requirements with international IEC 62930 (62930 IEC 131) for metric Class 5 tinned-copper 1500V DC photovoltaic cables. UL 4703 is the North American NEC Article 690 standard built in AWG sizes with UL listing requirements; projects crossing regions should verify dual-standard marking or local authority approval rather than assuming direct interchangeability.
- Does CASMO hold third-party TÜV certification for EN 50618 solar cables?
- Yes — CASMO's H1Z2Z2-K solar photovoltaic cables (1.5 mm² to 35 mm², 1500V DC, −40°C to +90°C ambient / +120°C max conductor) are certified under TÜV Rheinland Certificate R 50693675, which can be downloaded directly from CASMO's Quality & Compliance page.
Engineering Guides
- XLPE Cross-Linking Methods Compared: Electron-Beam Irradiation vs. Chemical Peroxide (CCV) vs. Silane (Sioplas & Monosil) — How electron-beam irradiation, chemical peroxide CCV curing, and silane moisture cross-linking convert polyethylene into thermoset XLPE — comparing thermal rating, wall-thickness limits, scorch risk, hot-set QC testing, and XLPE/XLPO/XLPVC/XL-ETFE wire standards.