RTD-GGP
RTD-GGP is a CASMO rtd cable for RTD / PT100 Cable. Fiberglass insulated, 0°C to +480°C. Armored 3-core stranded 27% nickel-coated copper high-temperature PT100 / RTD cable with fiberglass core braid, fiberglass inner jacket, and outer 304 stainless steel wire overbraid (0°C to +480°C).
Armored 3-core stranded 27% nickel-coated copper high-temperature PT100 / RTD cable with fiberglass core braid, fiberglass inner jacket, and outer 304 stainless steel wire overbraid (0°C to +480°C).
Key Ratings
- RTD-GGP: · Temperature 0°C to +480°C
Construction
- Conductor
- Nickel-Coated Copper (27%) or Pure Nickel · Stranded
- Core Insulation
- Braided · Fiberglass
- Cabling
- Laid Up · 3-core concentric twist
- Core Identification
- 3-wire IEC 60751 high-temperature tracer code (2 White w/ Red tracer + 1 Solid White)
- Jacket
- Braided · Fiberglass
- Braid
- Stainless steel wire overbraid (304 SS)
Characteristics
- Saturant & Tracer Volatilization: High-temperature silicone resin saturant and organic dye tracers volatilize above +204°C while braided fiberglass insulation maintains continuous electrical separation up to +480°C; retain polarity tags at cold terminations.
- Signal Circuit Duty: Dry-location low-voltage RTD measurement signal circuits only; porous braided fiberglass insulation is not voltage-rated for mains power circuits.
- Low-Resistance Lead Compensation: Matched three-conductor copper construction minimizes lead-wire resistance imbalance in bridge-connected RTD circuits.
- Stainless Steel Overbraid Protection: Woven 304 stainless steel wire armor protects the cable against mechanical abrasion, cut-through and crush loads.
- High-Temperature Thermal Stability: Heat-resistant insulation and jacketing resist thermal aging, embrittlement and cut-through in elevated-temperature zones.
- Mechanical Strength: Provides mechanical strength to withstand handling and installation stresses and help maintain cable integrity.
Applications
- PT100 and RTD Resistance Thermometry: For three-wire resistance thermometer lead connections between RTD sensors, transmitters and temperature controllers.
- High-Temperature Ovens, Kilns and Heat Treatment: For high-temperature Pt100 / RTD resistance sensor lead wiring on industrial ovens, autoclaves, heat-treating equipment and thermal processing lines.
- Process & Plant RTD Instrumentation: For Pt100 / Pt1000 resistance sensor lead circuits across power-generation, chemical, petrochemical and metallurgical facilities.
Standards & Compliance
- Standard: IEC 60751
- RoHS: Compliant
- REACH: Compliant
RTD-GGP — 3-Core Fiberglass & 304 SS Overbraided 480°C RTD Cable
| CASMO Part No. | Total Cores | Conductor Size (AWG) | No. Of Strands | Nom. Strand Dia. (mm) | Nom. Conductor Dia. (mm) | Nom. Ins. Thickness (mm) | Nom. Core O.D. (mm) | Nom. Jkt. Thickness (mm) | Nom. Shield Thickness (mm) | Nom. O.D. (mm) | O.D. Tolerance ± (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 710423C26-NC27-XX | 3 | 26 | 7 | 0.16 | 0.48 | 0.2 | 0.9 | 0.2 | 0.2 | 2.7 | 0.2 |
| 710423C24-NC27-XX | 3 | 24 | 7 | 0.2 | 0.6 | 0.2 | 1.0 | 0.2 | 0.2 | 3.0 | 0.2 |
| 710423C22-NC27-XX | 3 | 22 | 7 | 0.254 | 0.76 | 0.2 | 1.2 | 0.2 | 0.2 | 3.4 | 0.2 |
| 710423C20-NC27-XX | 3 | 20 | 7 | 0.32 | 0.96 | 0.2 | 1.4 | 0.2 | 0.2 | 3.8 | 0.2 |
| 710423C18-NC27-XX | 3 | 18 | 7 | 0.39 | 1.17 | 0.2 | 1.6 | 0.2 | 0.2 | 4.2 | 0.2 |
| 710423C16-NC27-XX | 3 | 16 | 19 | 0.3 | 1.5 | 0.2 | 1.9 | 0.2 | 0.2 | 4.9 | 0.2 |
| 710423C14-NC27-XX | 3 | 14 | 19 | 0.37 | 1.85 | 0.2 | 2.3 | 0.2 | 0.2 | 5.8 | 0.2 |
* "-NC27-" = stranded 27% nickel-coated copper conductor (standard for 480°C fiberglass RTD cable). "-N-" = pure nickel conductor (optional). Standard 3-core IEC 60751 configuration (2 White w/ Red tracer + 1 Solid White); 2-core (2C) and 4-core (4C) constructions available upon request. † "-XX" = fiberglass inner jacket tracer code under natural 304 stainless steel wire overbraid (WH White with Red tracer standard).
- "-NC27-" = stranded 27% nickel-coated copper conductor (standard for 480°C fiberglass RTD cable). "-N-" = pure nickel conductor (optional). Standard 3-core IEC 60751 configuration (2 White w/ Red tracer + 1 Solid White); 2-core (2C) and 4-core (4C) constructions available upon request.
- "-XX" = fiberglass inner jacket tracer code under natural 304 stainless steel wire overbraid (WH White with Red tracer standard).
Color Code Chart
- White w/ Red tracer (Lead A)
- White w/ Red tracer (Lead A')
- Solid White (Sense B)