RTD-VPV

RTD-VPV is a CASMO rtd cable for RTD / PT100 Cable. PVC insulated, -20°C to +105°C. 3-core stranded tinned-copper RTD / PT100 cable with extruded PVC cores, internal tinned copper braid EMI shield, and extruded PVC outer jacket (-20°C to +105°C).

3-core stranded tinned-copper RTD / PT100 cable with extruded PVC cores, internal tinned copper braid EMI shield, and extruded PVC outer jacket (-20°C to +105°C).

Key Ratings

  • RTD-VPV: · Temperature -20°C to +105°C

Construction

Conductor
Tinned Copper · Stranded
Core Insulation
Extruded · PVC
Cabling
Laid Up · 3-core concentric twist
Core Identification
3-wire IEC 60751 color code (2 Red + 1 White)
Shield
Braid · Tinned copper braid (≥85%)
Jacket
Extruded · PVC

Characteristics

  • Signal Circuit Duty: Low-voltage RTD excitation and bridge measurement signal circuits only (not rated for mains power distribution); extruded core insulation is factory dielectric-verified at 1000 V AC for 1 min.
  • Low-Resistance Lead Compensation: Matched three-conductor copper construction minimizes lead-wire resistance imbalance in bridge-connected RTD circuits.
  • EMC Interference Shielding: Metallic shielding helps suppress electromagnetic interference and maintain signal integrity in electrically noisy environments.
  • Moisture Resistance: Resistant to moisture and humidity, helping maintain the integrity of the cable covering in damp environments.
  • Oil Resistance: Resistant to oil exposure, helping maintain the integrity of the cable covering in oily environments.

Applications

  • PT100 and RTD Resistance Thermometry: For three-wire resistance thermometer lead connections between RTD sensors, transmitters and temperature controllers.
  • Control Cabinets: For wiring within control cabinets, control panels and electrical assemblies.
  • Sensors and Instrumentation: For connections between sensors, measuring instruments and associated control equipment.

Standards & Compliance

  • Standard: IEC 60751
  • RoHS: Compliant
  • REACH: Compliant

RTD-VPV — 3-Core PVC Insulated, TPC Shielded & PVC RTD Cable

CASMO Part No.Total CoresConductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Nom. Core O.D. (mm)Nom. Shield Thickness (mm)Nom. Jkt. Thickness (mm)Nom. O.D. (mm)O.D. Tolerance ± (mm)
710343C26-TS-XX32670.160.480.31.10.20.94.60.2
710343C24-TS-XX32470.20.60.31.20.20.94.80.2
710343C22-TS-XX32270.2540.760.31.40.21.05.40.2
710343C20-TS-XX32070.320.960.31.60.21.05.80.2
710343C18-TS-XX31870.391.170.42.00.21.06.70.3
710343C16-TS-XX316190.31.50.42.30.31.17.80.3
710343C14-TS-XX314190.371.850.52.90.31.19.00.3

* "-TS-" = stranded tinned copper conductor with tinned copper braid EMI shield (standard for 105°C PVC RTD cable; "-SS-" silver-plated copper or "-NS-" 2% nickel-plated copper optional). Standard 3-core IEC 60751 configuration (2 Red + 1 White); 2-core (2C) and 4-core (4C) constructions available upon request. † "-XX" = outer jacket color code: RD Red (standard), WH White, BK Black, or GY Grey (3-core identification per Color Code Chart below).

  • "-TS-" = stranded tinned copper conductor with tinned copper braid EMI shield (standard for 105°C PVC RTD cable; "-SS-" silver-plated copper or "-NS-" 2% nickel-plated copper optional). Standard 3-core IEC 60751 configuration (2 Red + 1 White); 2-core (2C) and 4-core (4C) constructions available upon request.
  • "-XX" = outer jacket color code: RD Red (standard), WH White, BK Black, or GY Grey (3-core identification per Color Code Chart below).