TC-CGP

TC-CGP is a CASMO thermocouple wire for Thermocouple Wire. Fiberglass insulated, 0°C to +480°C. Compact armored 2-core parallel flat thermocouple wire with thin-wall wrapped fiberglass core insulation, braided fiberglass inner jacket, and outer 304 stainless steel wire overbraid (0°C to +480°C).

Compact armored 2-core parallel flat thermocouple wire with thin-wall wrapped fiberglass core insulation, braided fiberglass inner jacket, and outer 304 stainless steel wire overbraid (0°C to +480°C).

Key Ratings

  • TC-CGP: · Temperature 0°C to +480°C

Construction

Conductor
Thermocouple Alloy (Type K / N / E / J) · Stranded
Core Insulation
Wrapped · Fiberglass
Cabling
Parallel · Duplex parallel flat core pair
Core Identification
Color-coded fiberglass tracer per IEC 60584-3 (Type K: +White w/ Green tracer / -White) or ASTM E230 on request
Jacket
Braided · Fiberglass
Braid
Stainless steel wire overbraid (304 SS)

Characteristics

  • Short-Term Peak Temperature: +540°C (single-exposure E-glass limit)
  • Saturant & Tracer Volatilization: Silicone resin saturant and organic dye tracers volatilize or fade above +204°C while braided fiberglass maintains continuous electrical separation up to +480°C; retain polarity tags at cold terminations.
  • Signal Circuit Duty: Dry-location low-voltage thermoelectric millivolt EMF measurement circuits only; porous fiberglass insulation is not voltage-rated for mains power circuits.
  • Calibrated EMF Accuracy: Matched thermoelectric conductor pairs maintain stable electromotive force characteristics across the rated temperature span.
  • Stainless Steel Overbraid Protection: Woven 304 stainless steel wire armor protects the cable against mechanical abrasion, cut-through and crush loads.
  • Ultra-Thin Compact Profile: Compact parallel duplex geometry reduces bundle cross-section for tight sensor feedthroughs, vacuum chambers and test fixtures.
  • High-Temperature Thermal Stability: Heat-resistant insulation and jacketing resist thermal aging, embrittlement and cut-through in elevated-temperature zones.

Applications

  • Industrial Furnaces, Kilns and Heat Treatment: For temperature measurement and extension wiring on heat-treating furnaces, ceramic kilns, ovens and thermal processing lines.
  • Process Temperature Sensing and Pyrometry: For connecting thermocouple probes and cold-junction transmitters across chemical, petrochemical, power-generation and metallurgical plants.

Standards & Compliance

  • Standard: IEC 60584-1 / ASTM E230
  • RoHS: Compliant
  • REACH: Compliant

TC-CGP — Thin-Wall Fiberglass & 304 SS Overbraided 480°C Wire

CASMO Part No.Total CoresConductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Nom. Core O.D. (mm)Nom. Jkt. Thickness (mm)Nom. Shield Thickness (mm)Nom. Overall Width (mm)Overall Width Tolerance ± (mm)Nom. Overall Thickness (mm)Overall Thickness Tolerance ± (mm)
710252C26-K-XX22670.160.480.130.740.20.22.30.21.50.2
710252C24-K-XX22470.20.60.130.860.20.22.50.21.70.2
710252C22-K-XX22270.2540.760.131.020.20.22.80.21.80.2
710252C20-K-XX22070.320.960.131.220.20.23.20.22.00.2
710252C18-K-XX21870.391.170.131.430.20.23.70.22.20.2
710252C16-K-XX216190.31.50.131.760.20.24.30.22.60.2
710252C14-K-XX214190.371.850.132.110.20.25.00.22.90.2

* "-K-" = Type K thermocouple-grade alloy pair (NiCr / NiAl, standard). Substitute "-N-" (Type N), "-E-" (Type E), or "-J-" (Type J; note wire-gauge oxidation limit: 26–24 AWG ≤ +370°C, 22–20 AWG ≤ +480°C). Extension-grade alloys and Type T are not supplied for +480°C fiberglass service. † "-XX" = color-code suffix: IEC 60584-3 fiberglass tracer code supplied as standard (e.g., GN for Type K); ASTM E230 tracer code available upon request (see Color Code Chart below). Organic dye tracers and silicone saturant volatilize/fade above +204°C; retain polarity tags at cold terminations.

  • "-K-" = Type K thermocouple-grade alloy pair (NiCr / NiAl, standard). Substitute "-N-" (Type N), "-E-" (Type E), or "-J-" (Type J; note wire-gauge oxidation limit: 26–24 AWG ≤ +370°C, 22–20 AWG ≤ +480°C). Extension-grade alloys and Type T are not supplied for +480°C fiberglass service.
  • "-XX" = color-code suffix: IEC 60584-3 fiberglass tracer code supplied as standard (e.g., GN for Type K); ASTM E230 tracer code available upon request (see Color Code Chart below). Organic dye tracers and silicone saturant volatilize/fade above +204°C; retain polarity tags at cold terminations.

Color Code Chart

  • +White w/ Green tracer / -White (Jkt: White w/ Green tracer)
  • +White w/ Black tracer / -White (Jkt: White w/ Black tracer)
  • +White w/ Violet tracer / -White (Jkt: White w/ Violet tracer)
  • +White w/ Pink tracer / -White (Jkt: White w/ Pink tracer)
  • +Yellow tracer / -Red tracer (Jkt: Brown or Yellow tracer)
  • +White / -Red tracer (Jkt: Brown or Black tracer)
  • +Purple tracer / -Red tracer (Jkt: Brown or Purple tracer)
  • +Orange tracer / -Red tracer (Jkt: Brown or Orange tracer)

Related Categories