TC-GGP
TC-GGP is a CASMO thermocouple wire for Thermocouple Wire. Fiberglass insulated, 0°C to +480°C. Armored 2-core parallel flat high-temperature thermocouple wire with braided fiberglass core insulation, braided fiberglass inner jacket, and protective outer 304 stainless steel wire overbraid (0°C to…
Armored 2-core parallel flat high-temperature thermocouple wire with braided fiberglass core insulation, braided fiberglass inner jacket, and protective outer 304 stainless steel wire overbraid (0°C to +480°C).
Key Ratings
- TC-GGP: · Temperature 0°C to +480°C
Construction
- Conductor
- Thermocouple Alloy (Type K / N / E / J) · Stranded
- Core Insulation
- Braided · Fiberglass
- Cabling
- Parallel · Duplex parallel flat core pair
- Core Identification
- Color-coded fiberglass tracer per IEC 60584-3 (Type K: +White w/ Green tracer / -White) or ASTM E230 on request
- Jacket
- Braided · Fiberglass
- Braid
- Stainless steel wire overbraid (304 SS)
Characteristics
- Short-Term Peak Temperature: +540°C (single-exposure E-glass limit)
- Saturant & Tracer Volatilization: Silicone resin saturant and organic dye tracers volatilize or fade above +204°C while braided fiberglass maintains continuous electrical separation up to +480°C; retain polarity tags at cold terminations.
- Signal Circuit Duty: Dry-location low-voltage thermoelectric millivolt EMF measurement circuits only; porous fiberglass insulation is not voltage-rated for mains power circuits.
- Calibrated EMF Accuracy: Matched thermoelectric conductor pairs maintain stable electromotive force characteristics across the rated temperature span.
- Stainless Steel Overbraid Protection: Woven 304 stainless steel wire armor protects the cable against mechanical abrasion, cut-through and crush loads.
- High-Temperature Thermal Stability: Heat-resistant insulation and jacketing resist thermal aging, embrittlement and cut-through in elevated-temperature zones.
- Mechanical Strength: Provides mechanical strength to withstand handling and installation stresses and help maintain cable integrity.
Applications
- Industrial Furnaces, Kilns and Heat Treatment: For temperature measurement and extension wiring on heat-treating furnaces, ceramic kilns, ovens and thermal processing lines.
- Process Temperature Sensing and Pyrometry: For connecting thermocouple probes and cold-junction transmitters across chemical, petrochemical, power-generation and metallurgical plants.
Standards & Compliance
- Standard: IEC 60584-1 / ASTM E230
- RoHS: Compliant
- REACH: Compliant
TC-GGP — Braided Fiberglass & 304 SS Overbraided 480°C Duplex Wire
| CASMO Part No. | Total Cores | Conductor Size (AWG) | No. Of Strands | Nom. Strand Dia. (mm) | Nom. Conductor Dia. (mm) | Nom. Ins. Thickness (mm) | Nom. Core O.D. (mm) | Nom. Jkt. Thickness (mm) | Nom. Shield Thickness (mm) | Nom. Overall Width (mm) | Overall Width Tolerance ± (mm) | Nom. Overall Thickness (mm) | Overall Thickness Tolerance ± (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 710202C26-K-XX | 2 | 26 | 7 | 0.16 | 0.48 | 0.2 | 0.9 | 0.2 | 0.2 | 2.6 | 0.2 | 1.7 | 0.2 |
| 710202C24-K-XX | 2 | 24 | 7 | 0.2 | 0.6 | 0.2 | 1.0 | 0.2 | 0.2 | 2.8 | 0.2 | 1.8 | 0.2 |
| 710202C22-K-XX | 2 | 22 | 7 | 0.254 | 0.76 | 0.2 | 1.2 | 0.2 | 0.2 | 3.2 | 0.2 | 2.0 | 0.2 |
| 710202C20-K-XX | 2 | 20 | 7 | 0.32 | 0.96 | 0.2 | 1.4 | 0.2 | 0.2 | 3.6 | 0.2 | 2.2 | 0.2 |
| 710202C18-K-XX | 2 | 18 | 7 | 0.39 | 1.17 | 0.2 | 1.6 | 0.2 | 0.2 | 4.0 | 0.2 | 2.4 | 0.2 |
| 710202C16-K-XX | 2 | 16 | 19 | 0.3 | 1.5 | 0.2 | 1.9 | 0.2 | 0.2 | 4.6 | 0.2 | 2.7 | 0.2 |
| 710202C14-K-XX | 2 | 14 | 19 | 0.37 | 1.85 | 0.2 | 2.3 | 0.2 | 0.2 | 5.4 | 0.2 | 3.1 | 0.2 |
* "-K-" = Type K thermocouple-grade alloy pair (NiCr / NiAl, standard). Substitute "-N-" (Type N), "-E-" (Type E), or "-J-" (Type J; note wire-gauge oxidation limit: 26–24 AWG ≤ +370°C, 22–20 AWG ≤ +480°C). Extension-grade alloys and Type T are not supplied for +480°C fiberglass service. † "-XX" = color-code suffix: IEC 60584-3 fiberglass tracer code supplied as standard (e.g., GN for Type K); ASTM E230 tracer code available upon request (see Color Code Chart below). Organic dye tracers and silicone saturant volatilize/fade above +204°C; retain polarity tags at cold terminations.
- "-K-" = Type K thermocouple-grade alloy pair (NiCr / NiAl, standard). Substitute "-N-" (Type N), "-E-" (Type E), or "-J-" (Type J; note wire-gauge oxidation limit: 26–24 AWG ≤ +370°C, 22–20 AWG ≤ +480°C). Extension-grade alloys and Type T are not supplied for +480°C fiberglass service.
- "-XX" = color-code suffix: IEC 60584-3 fiberglass tracer code supplied as standard (e.g., GN for Type K); ASTM E230 tracer code available upon request (see Color Code Chart below). Organic dye tracers and silicone saturant volatilize/fade above +204°C; retain polarity tags at cold terminations.
Color Code Chart
- +White w/ Green tracer / -White (Jkt: White w/ Green tracer)
- +White w/ Black tracer / -White (Jkt: White w/ Black tracer)
- +White w/ Violet tracer / -White (Jkt: White w/ Violet tracer)
- +White w/ Pink tracer / -White (Jkt: White w/ Pink tracer)
- +Yellow tracer / -Red tracer (Jkt: Brown or Yellow tracer)
- +White / -Red tracer (Jkt: Brown or Black tracer)
- +Purple tracer / -Red tracer (Jkt: Brown or Purple tracer)
- +Orange tracer / -Red tracer (Jkt: Brown or Orange tracer)