TC-VVP

TC-VVP is a CASMO thermocouple wire for Thermocouple Wire. PVC insulated, -20°C to +105°C. 2-core parallel flat thermocouple and extension cable with extruded PVC core insulation, PVC inner jacket, and protective outer 304 stainless steel wire overbraid (-20°C to +105°C).

2-core parallel flat thermocouple and extension cable with extruded PVC core insulation, PVC inner jacket, and protective outer 304 stainless steel wire overbraid (-20°C to +105°C).

Key Ratings

  • TC-VVP: · Temperature -20°C to +105°C

Construction

Conductor
Thermocouple Alloy (Type K / J / T / E / N) or Extension / Compensating Alloy (Type KX / JX / TX / EX / NX / RX / SX) · Stranded
Core Insulation
Extruded · PVC
Cabling
Parallel · Duplex parallel flat core pair
Core Identification
Color-coded per IEC 60584-3 (Type K/KX: +Green / -White) or ASTM E230 on request
Jacket
Extruded · PVC
Braid
Stainless steel wire overbraid (304 SS)

Characteristics

  • Signal Circuit Duty: Low-voltage thermoelectric millivolt EMF measurement and extension signal circuits only (not rated for mains power distribution).
  • Calibrated EMF Accuracy: Matched thermoelectric conductor pairs maintain stable electromotive force characteristics across the rated temperature span.
  • Stainless Steel Overbraid Protection: Woven 304 stainless steel wire armor protects the cable against mechanical abrasion, cut-through and crush loads.
  • Abrasion Resistance: Resistant to abrasion, helping protect the cable surface against wear caused by rubbing and handling.
  • Moisture Resistance: Resistant to moisture and humidity, helping maintain the integrity of the cable covering in damp environments.

Applications

  • Process Temperature Sensing and Pyrometry: For connecting thermocouple probes and cold-junction transmitters across chemical, petrochemical, power-generation and metallurgical plants.
  • Industrial Automation: For power, signal or control connections within industrial automation systems, as specified for the selected cable construction.
  • Sensors and Instrumentation: For connections between sensors, measuring instruments and associated control equipment.

Standards & Compliance

  • Standard: IEC 60584-3 / ASTM E230
  • RoHS: Compliant
  • REACH: Compliant

TC-VVP — PVC Insulated & 304 SS Overbraided Duplex Wire

CASMO Part No.Total CoresConductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Nom. Core O.D. (mm)Nom. Jkt. Thickness (mm)Nom. Shield Thickness (mm)Nom. Overall Width (mm)Overall Width Tolerance ± (mm)Nom. Overall Thickness (mm)Overall Thickness Tolerance ± (mm)
710022C26-KX-XX22670.160.480.31.10.50.23.60.22.50.2
710022C24-KX-XX22470.20.60.31.20.50.23.80.22.60.2
710022C22-KX-XX22270.2540.760.31.40.50.24.20.22.80.2
710022C20-KX-XX22070.320.960.31.60.50.24.60.23.00.2
710022C18-KX-XX21870.391.170.42.00.60.25.60.23.60.2
710022C16-KX-XX216190.31.50.42.30.60.26.20.23.90.2
710022C14-KX-XX214190.371.850.42.70.60.27.00.24.30.2

* "-KX-" = Type KX extension-grade alloy pair (NiCr / NiAl, standard; EMF calibrated up to +200°C). Substitute "-JX-", "-EX-", "-NX-", "-RX-", "-SX-" (EMF calibrated ≤ +200°C), "-TX-" (EMF calibrated ≤ +100°C), or thermocouple-grade "-K-", "-J-", "-T-", "-E-", "-N-" for sensing-junction service (Type T wire-gauge limit: +200°C for 26–20 AWG). † "-XX" = core/inner-jacket color-code suffix under natural 304 stainless steel wire overbraid: IEC 60584-3 color code supplied as standard (e.g., GN for Type K/KX); ASTM E230 color code available upon request (see Color Code Chart below).

  • "-KX-" = Type KX extension-grade alloy pair (NiCr / NiAl, standard; EMF calibrated up to +200°C). Substitute "-JX-", "-EX-", "-NX-", "-RX-", "-SX-" (EMF calibrated ≤ +200°C), "-TX-" (EMF calibrated ≤ +100°C), or thermocouple-grade "-K-", "-J-", "-T-", "-E-", "-N-" for sensing-junction service (Type T wire-gauge limit: +200°C for 26–20 AWG).
  • "-XX" = core/inner-jacket color-code suffix under natural 304 stainless steel wire overbraid: IEC 60584-3 color code supplied as standard (e.g., GN for Type K/KX); ASTM E230 color code available upon request (see Color Code Chart below).

Color Code Chart

  • +Green / -White (Jkt: Green)
  • +Black / -White (Jkt: Black)
  • +Brown / -White (Jkt: Brown; TX ≤100°C)
  • +Violet / -White (Jkt: Violet)
  • +Pink / -White (Jkt: Pink)
  • +Orange / -White (Jkt: Orange; ≤100°C)
  • +Yellow / -Red (TC: Brown / Ext: Yellow)
  • +White / -Red (TC: Brown / Ext: Black)
  • +Blue / -Red (TC: Brown / Ext: Blue; TX ≤100°C)
  • +Purple / -Red (TC: Brown / Ext: Purple)
  • +Orange / -Red (TC: Brown / Ext: Orange)
  • +Black / -Red (Ext: Green; ≤200°C)

Related Categories