TYPE W SINGLE-CONDUCTOR

TYPE W SINGLE-CONDUCTOR is a CASMO flexible cord for Flexible Cords. EPDM insulated, -40°C to +90°C, 2000V. Type W single-conductor portable power cable constructed in accordance with UL 1650 (−40°C to +90°C wet and dry, 2000V AC) with extra-flexible bare copper conductor, PET separator, thermose…

Type W single-conductor portable power cable constructed in accordance with UL 1650 (−40°C to +90°C wet and dry, 2000V AC) with extra-flexible bare copper conductor, PET separator, thermoset EPDM insulation and heavy-duty oil- and weather-resistant CPE outer jacket.

Key Ratings

  • TYPE W SINGLE-CONDUCTOR: · Temperature -40°C to +90°C · Rated Voltage 2000V

Construction

Conductor
Bare Copper · Extra-Flexible Stranded
Separator
PET tape over conductor
Insulation
Extruded · EPDM
Jacket
CPE · Extruded

Characteristics

  • Wet & Dry Rating: 90°C continuous wet and dry
  • Oil Immersion Rating: 75°C (60 days immersion; ≥ 65% tensile and elongation retention)
  • Cold Bend: −40°C × 4 h, no cracking
  • Spark Test Voltage: 10 kV (12–2 AWG); 13 kV (1–4/0 AWG); 15 kV (250–500 kcmil)
  • Dielectric Withstand Voltage (1 min): 3 kV (12–10 AWG); 4 kV (8–2 AWG); 5 kV (1–4/0 AWG); 6 kV (250–500 kcmil)
  • Oil Resistance: Resistant to oil exposure, helping maintain the integrity of the cable covering in oily environments.
  • Weather Resistance: Resistant to weathering, helping maintain cable integrity under exposure to sunlight, moisture and changing weather conditions.
  • Abrasion Resistance: Resistant to abrasion, helping protect the cable surface against wear caused by rubbing and handling.
  • Low-Temperature Flexibility: Maintains flexibility at low temperatures, facilitating cable routing and handling in cold environments.

Applications

  • Portable Tools and Industrial Equipment: For portable power tools, mobile machinery and temporary industrial power connections, subject to the applicable service cord rating and installation conditions.
  • Industrial Automation: For power, signal or control connections within industrial automation systems, as specified for the selected cable construction.
  • Heavy-Duty Temporary Power Distribution: For mobile generators, power feeders, stage and industrial distribution boxes, motor leads and rugged wet-location equipment connections rated up to 2000V AC.

Standards & Compliance

  • Standard: UL 1650
  • Fire Performance: FT1, FT5
  • RoHS: Compliant
  • REACH: Compliant

Single-Conductor (1C)

CASMO Part No.Conductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Min. Ins. Thickness (mm)Nom. Jkt. Thickness (mm)Min. Jkt. Thickness (mm)Nom. O.D. (mm)O.D. Tolerance ± (mm)Max. DCR @20°C (Ω/km)
1114211C1212650.2542.401.521.371.911.539.60.55.43
1114211C10101050.2543.001.521.371.911.5310.30.53.41
1114211C881680.2543.901.521.371.911.5311.40.62.18
1114211C662660.2544.901.521.372.411.9313.40.61.38
1114211C444270.2546.301.521.372.411.9314.70.60.865
1114211C335320.2547.001.521.372.411.9315.40.60.693
1114211C226650.2547.901.521.372.411.9316.40.80.549
1114211C118550.2549.102.031.832.411.9318.50.80.436
1114211C1_01/010450.25410.202.031.832.411.9319.51.00.345
1114211C2_02/013300.25411.502.031.832.411.9320.91.00.273
1114211C3_03/016720.25412.802.031.832.411.9322.11.00.217
1114211C4_04/021090.25414.402.031.832.411.9323.71.00.172
1114211C250MCM250 kcmil25160.25415.602.412.172.411.9325.71.20.147
1114211C350MCM350 kcmil34780.25418.402.412.172.411.9328.41.20.105
1114211C500MCM500 kcmil12250.51121.902.412.172.411.9331.91.50.0735

* Bare annealed copper stranding per ASTM B172: Class K for 12 AWG–350 kcmil and Class I for 500 kcmil. Standard core insulation color is White under a Black CPE outer jacket. † UL 1650 Type W Listing covers 8 AWG through 500 kcmil; 12 AWG and 10 AWG are constructed to equivalent Type W dimensional and performance guidelines.

  • Bare annealed copper stranding per ASTM B172: Class K for 12 AWG–350 kcmil and Class I for 500 kcmil. Standard core insulation color is White under a Black CPE outer jacket.
  • UL 1650 Type W Listing covers 8 AWG through 500 kcmil; 12 AWG and 10 AWG are constructed to equivalent Type W dimensional and performance guidelines.