Flexible Power Cords
Portable, high-flex power and service cords for tools, industrial equipment, machinery and appliances — spanning heavy-duty thermoset rubber and lightweight thermoplastic constructions under UL 62 and international equivalents.
Portable & flexing power cords across service grades
Portable flexible cords connect tools, motors, industrial equipment, stage lighting and appliances that move, vibrate or experience repeated coiling and dragging. Unlike fixed panel or building wire, flexible cords combine finely stranded copper conductors with supple insulation and tough outer jackets engineered to survive continuous bending, impact, moisture and oil exposure across wide temperature ranges.
Under UL 62 (harmonised with CSA C22.2 No. 49), cord letter codes systematically define service duty and compound chemistry: hard-service 600V grades (S / ST) versus junior-service 300V grades (SJ / SV), thermoset rubber/EPDM/CPE compounds for extreme weather, oil and outdoor abuse (such as SOOW and SJOOW) versus lightweight thermoplastic PVC cords for indoor tools and appliances (such as SJT, SJTW, STOW and SVT). For European and international equipment, harmonised rubber and PVC flexible cords (such as H07RN-F) serve analogous portable-power roles.
CASMO manufactures thermoset and thermoplastic flexible power cords across standard core counts and AWG/metric gauges so OEMs, equipment builders and MRO teams can match exact voltage, oil, water and flex-life requirements.
Flexible Cords Products
Related Standards, Materials & Applications
Frequently Asked Questions
- How do I read a UL 62 flexible cord letter code?
- Read left to right: the prefix sets voltage and service class (S = 600V Hard Service, SJ = 300V Junior Service, SV = light vacuum/appliance cord), followed by T = thermoplastic (PVC) jacket (omitted for thermoset rubber/CPE), O = oil-resistant jacket (OO = oil-resistant insulation and jacket), and W = weather/water-resistant for outdoor use.
- When should I choose a thermoset cord (SOOW / SJOOW) over a thermoplastic cord (SJT / SJTW / STOW)?
- Choose thermoset EPDM/CPE rubber cords (SOOW, SJOOW) for rugged outdoor sites, heavy abrasion, wide temperature swings and continuous oil/water exposure. Choose thermoplastic PVC cords (SJT, SJTW, STOW, SVT) when lighter weight and lower cost suit indoor tools, appliances and moderate industrial duty.
- What is the difference between 600V Hard Service and 300V Junior Service cords?
- Hard Service cords (such as SOOW and STOW) use thicker insulation and outer jackets rated 600V for heavy industrial equipment and rough job sites; Junior Service cords (such as SJOOW, SJT and SJTW) are more compact 300V cords designed for portable tools, lighting and light machinery.
- Which standards govern portable flexible power cords?
- In North America, portable cords are governed by UL 62 and CSA C22.2 No. 49 (with NEC Article 400 governing installation). Internationally, harmonised EN 50525 / IEC 60245 rubber and PVC flexible cords cover equivalent portable power applications.