XE150-L
XE150-L is a CASMO wire & cable for Aerospace. XL-ETFE insulated, -65°C to +150°C, 600V.
Key Ratings
- XE150-L: · Temperature -65°C to +150°C · Rated Voltage 600V · Test Voltage 2500V (Post-environmental, 60 Hz rms. Spark 5.7 kV rms, 3 kHz. Impulse 8.0 kV peak.)
Construction
- Conductor
- Tinned Copper
- Insulation
- Single-layer extruded · XL-ETFE
Characteristics
- Lightweight Thin Wall: Single-wall XL-ETFE keeps diameter and weight low for dense harnesses.
- Cut-Through & Abrasion Resistance: Tough crosslinked insulation resists cut-through, abrasion and chafing.
- Fluid Resistance: Resistant to aviation fuels, lubricating oils, hydraulic fluids and common solvents.
- Soldering Heat Resistance: Non-melting insulation withstands soldering-iron contact.
Applications
- Light airframe and equipment wire: Lightweight hook-up and airframe wire for aerospace, military and electronic equipment where space and weight are limited.
Standards & Compliance
- Standard: AS 22759
- RoHS: Compliant
- REACH: Compliant
Single-Core Wire
| CASMO Part No. | Conductor Size (AWG) | No. Of Strands | Strand Size (AWG) | Min. Conductor Dia. (mm) | Max. Conductor Dia. (mm) | Nom. O.D. (mm) | O.D. Tolerance ± (mm) | Max. DCR @20°C (Ω/km) | Max. Cable Weight (kg/km) |
|---|---|---|---|---|---|---|---|---|---|
| XE150-L-30-* | 30 | 7 | 38 | 0.28 | 0.33 | 0.61 | 0.05 | 356 | 0.98 |
| XE150-L-28-* | 28 | 7 | 36 | 0.36 | 0.41 | 0.69 | 0.05 | 225 | 1.35 |
| XE150-L-26-* | 26 | 19 | 38 | 0.46 | 0.51 | 0.81 | 0.05 | 135 | 2.08 |
| XE150-L-24-* | 24 | 19 | 36 | 0.58 | 0.64 | 0.94 | 0.05 | 86 | 2.98 |
| XE150-L-22-* | 22 | 19 | 34 | 0.74 | 0.79 | 1.09 | 0.05 | 53.1 | 4.17 |
| XE150-L-20-* | 20 | 19 | 32 | 0.94 | 0.99 | 1.27 | 0.05 | 32.4 | 6.40 |
| XE150-L-18-* | 18 | 19 | 30 | 1.17 | 1.24 | 1.52 | 0.05 | 20.4 | 9.67 |
| XE150-L-16-* | 16 | 19 | 29 | 1.32 | 1.40 | 1.73 | 0.05 | 15.8 | 12.4 |
| XE150-L-14-* | 14 | 19 | 27 | 1.65 | 1.75 | 2.16 | 0.08 | 10.0 | 19.3 |
| XE150-L-12-* | 12 | 37 | 28 | 2.13 | 2.26 | 2.62 | 0.08 | 6.63 | 29.3 |
| XE150-L-10-* | 10 | 37 | 26 | 2.69 | 2.87 | 3.25 | 0.10 | 4.13 | 47.3 |
| XE150-L-8-* | 8 | 133 | 29 | 4.01 | 4.39 | 4.78 | 0.20 | 2.30 | 87.5 |
* Replace "*" in part number with insulation color digit 0–9 per MIL-STD-681 (see Color Code Chart below; 9 White preferred). 1 Manufactured to SAE AS22759 (non-QPL); Max. DCR at 20°C and Max. Cable Weight are standard limits.
- Replace "*" in part number with insulation color digit 0–9 per MIL-STD-681 (see Color Code Chart below; 9 White preferred).
- Manufactured to SAE AS22759 (non-QPL); Max. DCR at 20°C and Max. Cable Weight are standard limits.
Color Code Chart
- Black
- Brown
- Red
- Orange
- Yellow
- Green
- Blue
- Violet
- Gray
- White