BUS L2-150 FD
BUS L2-150 FD is a CASMO industrial fieldbus cable for Industrial Fieldbus. Foam PE insulated, -40°C to +80°C, 250V. 150 Ω continuous-flex drag-chain L2 fieldbus cable with 19-strand bare copper conductors, Red/Green cellular PE cores, foil-plus-braid EMC screening and calibrated 8.0 mm halogen-f…
150 Ω continuous-flex drag-chain L2 fieldbus cable with 19-strand bare copper conductors, Red/Green cellular PE cores, foil-plus-braid EMC screening and calibrated 8.0 mm halogen-free violet PUR sheath.
Key Ratings
- BUS L2-150 FD: · Temperature -40°C to +80°C · Rated Voltage 250V · Test Voltage 1500V
Construction
- Conductor
- Bare Copper · Flexible Stranded
- Core Insulation
- Foamed · Foam PE
- Cabling
- Twisted
- Core Identification
- Red (Line B), Green (Line A)
- Shield
- Foil · Aluminum/polyester (Al/PET) foil
- Shield
- Braid · Tinned copper braid
- Jacket
- Extruded · PUR/TPU
Characteristics
- Continuous Flexing Temperature: -30°C to +70°C
- Characteristic Impedance: 150 Ω ± 15 Ω (3 to 20 MHz)
- Mutual Capacitance: Approx. 30 nF/km (at 800 Hz)
- Velocity of Propagation: Approx. 80%
- Continuous-Flex Durability: Designed to withstand repeated bending cycles in cable carriers and continuously moving machinery.
- Oil Resistance: Resistant to oil exposure, helping maintain the integrity of the cable covering in oily environments.
- Abrasion Resistance: Resistant to abrasion, helping protect the cable surface against wear caused by rubbing and handling.
- EMC Interference Shielding: Metallic shielding helps suppress electromagnetic interference and maintain signal integrity in electrically noisy environments.
Applications
- Cable Carriers and Moving Machinery: For dynamic signal and control routing in drag chains, gantries, linear axes and automated handling equipment.
- Fieldbus and Serial Data Networks: For differential serial and fieldbus communication links between programmable controllers, distributed I/O modules, drives and field devices.
Standards & Compliance
- Standard: IEC 61158-2
- Fire Performance: FT2
- RoHS: Compliant
- REACH: Compliant
Specification Data
| CASMO Part No. | Conductor Size (mm²) | No. Of Strands | Nom. Strand Dia. (mm) | Nom. Ins. Thickness (mm) | Nom. Core O.D. (mm) | Min. Braid Coverage (%) | Nom. Jkt. Thickness (mm) | Nom. O.D. (mm) | Max. DCR @20°C (Ω/km) |
|---|---|---|---|---|---|---|---|---|---|
| 1230040.34/19-1P-AS-VT | 1×2×0.34 | 19 | 0.15 | 0.90 | 2.55 | 65 | 1.10 | 8.0 | 57.5 |
* "-AS-" = 19-strand flexible bare copper conductor for drag-chain (FD) service; "-1P" = 1 twisted pair (Red Line B / Green Line A); "-VT" = violet (RAL 4001) PUR outer sheath calibrated to 8.0 mm O.D. † Max. DCR @20°C is specified per single conductor (57.5 Ω/km), corresponding to ≤ 115.0 Ω/km maximum DC loop resistance. Because flexible stranded conductors exceed the solid-core IEC 61158-2 Type A loop limit (110 Ω/km), derate maximum segment length by approximately 10%–20% depending on baud rate and flexible run share. ‡ Standard halogen-free PUR jacket meets FT2 flame rating; low-halogen VW-1 / FT1 jacket available upon request.
- "-AS-" = 19-strand flexible bare copper conductor for drag-chain (FD) service; "-1P" = 1 twisted pair (Red Line B / Green Line A); "-VT" = violet (RAL 4001) PUR outer sheath calibrated to 8.0 mm O.D.
- Max. DCR @20°C is specified per single conductor (57.5 Ω/km), corresponding to ≤ 115.0 Ω/km maximum DC loop resistance. Because flexible stranded conductors exceed the solid-core IEC 61158-2 Type A loop limit (110 Ω/km), derate maximum segment length by approximately 10%–20% depending on baud rate and flexible run share.
- Standard halogen-free PUR jacket meets FT2 flame rating; low-halogen VW-1 / FT1 jacket available upon request.