BUS L2-150 FD is a CASMO industrial fieldbus cable for Industrial Fieldbus. Foam PE insulated, -40°C to +80°C, 250V. 150 Ω continuous-flex drag-chain L2 fieldbus cable with 19-strand bare copper conductors, Red/Green cellular PE cores, foil-plus-braid EMC screening and calibrated 8.0 mm halogen-f…

150 Ω continuous-flex drag-chain L2 fieldbus cable with 19-strand bare copper conductors, Red/Green cellular PE cores, foil-plus-braid EMC screening and calibrated 8.0 mm halogen-free violet PUR sheath.

Key Ratings

  • BUS L2-150 FD: · Temperature -40°C to +80°C · Rated Voltage 250V · Test Voltage 1500V

Construction

Conductor
Bare Copper · Flexible Stranded
Core Insulation
Foamed · Foam PE
Cabling
Twisted
Core Identification
Red (Line B), Green (Line A)
Shield
Foil · Aluminum/polyester (Al/PET) foil
Shield
Braid · Tinned copper braid
Jacket
Extruded · PUR/TPU

Characteristics

  • Continuous Flexing Temperature: -30°C to +70°C
  • Characteristic Impedance: 150 Ω ± 15 Ω (3 to 20 MHz)
  • Mutual Capacitance: Approx. 30 nF/km (at 800 Hz)
  • Velocity of Propagation: Approx. 80%
  • Continuous-Flex Durability: Designed to withstand repeated bending cycles in cable carriers and continuously moving machinery.
  • Oil Resistance: Resistant to oil exposure, helping maintain the integrity of the cable covering in oily environments.
  • Abrasion Resistance: Resistant to abrasion, helping protect the cable surface against wear caused by rubbing and handling.
  • EMC Interference Shielding: Metallic shielding helps suppress electromagnetic interference and maintain signal integrity in electrically noisy environments.

Applications

  • Cable Carriers and Moving Machinery: For dynamic signal and control routing in drag chains, gantries, linear axes and automated handling equipment.
  • Fieldbus and Serial Data Networks: For differential serial and fieldbus communication links between programmable controllers, distributed I/O modules, drives and field devices.

Standards & Compliance

  • Standard: IEC 61158-2
  • Fire Performance: FT2
  • RoHS: Compliant
  • REACH: Compliant

Specification Data

CASMO Part No.Conductor Size (mm²)No. Of StrandsNom. Strand Dia. (mm)Nom. Ins. Thickness (mm)Nom. Core O.D. (mm)Min. Braid Coverage (%)Nom. Jkt. Thickness (mm)Nom. O.D. (mm)Max. DCR @20°C (Ω/km)
1230040.34/19-1P-AS-VT1×2×0.34190.150.902.55651.108.057.5

* "-AS-" = 19-strand flexible bare copper conductor for drag-chain (FD) service; "-1P" = 1 twisted pair (Red Line B / Green Line A); "-VT" = violet (RAL 4001) PUR outer sheath calibrated to 8.0 mm O.D. † Max. DCR @20°C is specified per single conductor (57.5 Ω/km), corresponding to ≤ 115.0 Ω/km maximum DC loop resistance. Because flexible stranded conductors exceed the solid-core IEC 61158-2 Type A loop limit (110 Ω/km), derate maximum segment length by approximately 10%–20% depending on baud rate and flexible run share. ‡ Standard halogen-free PUR jacket meets FT2 flame rating; low-halogen VW-1 / FT1 jacket available upon request.

  • "-AS-" = 19-strand flexible bare copper conductor for drag-chain (FD) service; "-1P" = 1 twisted pair (Red Line B / Green Line A); "-VT" = violet (RAL 4001) PUR outer sheath calibrated to 8.0 mm O.D.
  • Max. DCR @20°C is specified per single conductor (57.5 Ω/km), corresponding to ≤ 115.0 Ω/km maximum DC loop resistance. Because flexible stranded conductors exceed the solid-core IEC 61158-2 Type A loop limit (110 Ω/km), derate maximum segment length by approximately 10%–20% depending on baud rate and flexible run share.