PE — Solid & Cellular Polyethylene Insulation and Jacketing

Low-permittivity thermoplastic polyolefin used as solid or cellular (foam) core dielectric for impedance-controlled data and fieldbus cables, and as carbon-black UV-resistant outdoor jacketing.

What is PE & Foam PE insulation?

Polyethylene (PE) is a non-polar, halogen-free polyolefin featuring remarkably low dielectric permittivity (~2.3 solid, ~1.4–1.6 when cellular/foamed) and minimal moisture absorption. Extruded as cellular (foam) PE around twisted-pair conductors, micro-cellular gas cells lower mutual capacitance and raise propagation velocity — making Foam PE the preferred dielectric for 120 Ω and 150 Ω industrial fieldbus, RS-485, CAN and high-speed differential data cables.

Compounded with finely dispersed carbon black as an outer sheath, medium- and high-density PE forms a tough, low-permeability barrier against solar UV radiation, standing water, soil chemistry and −40°C cold impact for outdoor solar telemetry, energy-storage yards and utility SCADA runs.

Across cable designs, density grade determines performance: low-density (LDPE) and cellular Foam PE maximise flexibility and signal velocity (~78%–82% velocity of propagation in foam twisted pairs), whereas medium- and high-density (MDPE/HDPE) carbon-black compounds (typically 2%–2.5% UV-stabilising carbon black) deliver tough, low-friction outdoor and direct-burial sheaths with minimal moisture ingress.

Two engineering limits define PE's application boundary: as a non-cross-linked thermoplastic, PE softens above ~105°C–130°C (capping continuous ratings around 70°C–80°C, above which cross-linked XLPE is required); and unmodified PE is combustible rather than flame-retardant, so outdoor PE-jacketed cables entering occupied buildings must transition to flame-retardant or LSZH indoor cabling within applicable NEC or EU CPR entry-distance limits.

Key Material Properties

PropertyRatingNotes
Dielectricεr ~2.3 (solid) · ~1.5 (foam)Ultra-low mutual capacitance for serial data
Outdoor sheathUV- & moisture-resistant (black PE)Very low water-vapour permeability
Temperature−40°C to +80°C typicalHalogen-free thermoplastic polyolefin
Typical usesFieldbus, RS-485, data pairs, outdoor jacketsImpedance-matched & weatherproof cables
Grades & PropagationLDPE / Foam PE (cores) · Black MDPE/HDPE (sheaths)2%–2.5% carbon black for long-term UV stability
Fire & Thermal limitsNot inherently flame-retardant · ≤70°C–80°C cont.Upgrade to XLPE for 90°C–150°C or LSZH indoors

PE Insulated Products

  • LI2YCY-TP — DIN VDE 0812 / DIN 47100 · PE · -40°C to +80°C · 250V

Applications & Standards Using This Material

Frequently Asked Questions

Why do RS-485 and CAN fieldbus cables use Foam PE instead of PVC?
Foaming polyethylene introduces microscopic gas cells that cut dielectric constant and mutual capacitance roughly in half compared with PVC, preventing signal edge rounding and reflections over long trunk lines.
When is a black PE outer jacket preferred over PVC?
Carbon-black UV-stabilised PE excels in permanent outdoor, rooftop, underground duct and damp utility environments where sunlight stability and moisture exclusion outweigh indoor flame-retardant PVC requirements.
Can an outdoor black PE-jacketed cable be routed throughout an indoor commercial building?
Generally no — standard black PE jacketing is formulated for UV and moisture exclusion rather than flame retardancy and does not meet indoor riser, plenum or EU CPR flame-propagation classes. Per NEC and European building codes, transition outdoor PE cables to flame-retardant or LSZH indoor cabling at the building entrance.
When should engineers upgrade from thermoplastic PE to cross-linked XLPE?
Upgrade to XLPE whenever conductor temperatures exceed 70°C–80°C (for 90°C–150°C continuous operation), whenever overload/short-circuit non-melting endurance is mandatory, or whenever environmental stress-crack resistance under hot mechanical load is required.