DIN VDE 0812 — Electronic Control & Data Transmission Cables
European industrial signal, instrumentation and serial-data standard paired with DIN 47100 colour coding — spanning braided PVC, low-capacitance PE twisted-pair, halogen-free LSZH and oil-resistant PUR constructions.
Standard · VDE / DIN (German Electrotechnical Commission)
What is DIN VDE 0812?
DIN VDE 0812 (commonly paired with DIN 47100 core colour identification) is the benchmark European engineering specification for finely stranded electronic control, telemetry and data cables. Compact bare-copper stranding and slim core geometries deliver tight bend flexibility inside control cabinets, CNC machinery, robotics and industrial weighing or sensing systems.
Depending on EMC and environmental demands, standard constructions span tinned-copper braid-screened PVC (such as LiYCY), low-capacitance polyethylene twisted pairs for RS-422/RS-485 serial links (such as Li2YCY-TP), halogen-free low-smoke building and transit designs (such as LiHCH) and abrasion- and coolant-resistant polyurethane jackets (such as LiY11Y).
Standard PVC constructions (LiYY unscreened and LiYCY braided) typically operate across −40°C to +80°C fixed (−5°C to +70°C occasional flexing) at peak operating voltages of 350V (0.14 mm²) or 500V (0.25 mm² to 1.5 mm²), with typical minimum bending radii of 4×–6× O.D. fixed and 10× O.D. (unscreened) to 15× O.D. (braided) flexing. Because these cables are engineered for low-energy instrumentation, encoder and PLC signals, they are never approved for mains power distribution.
On screened LiYCY, Li2YCY-TP and LiHCH variants, the ~85% coverage tinned-copper braid provides low transfer impedance against VFD and contactor EMI — provided installers terminate the shield 360° via EMC cable glands rather than long unshielded drain pigtails.
Key Technical Requirements
| Parameter | Requirement | Notes |
|---|---|---|
| Core identification | DIN 47100 colour code | 44 distinct non-repeating core colour codes |
| EMC screening | Tinned-copper braid (~85% cover) | High EMC attenuation on screened types |
| Operating voltage | 350V peak (0.14 mm²) · 500V peak (≥0.25 mm²) | 250V peak on select PE data pairs; signal/control duty only |
| Jacket systems | PVC · LSZH · PUR/TPU | Matched to indoor, halogen-free or oily routing |
| Temperature & Bend | −40°C to +80°C fixed · −5°C to +70°C flex (PVC) | Min bend ~4×–6×D fixed / ~10×–15×D flexing |
| Mutual capacitance | ~100–150 pF/m (PVC) · Lower in PE (Li2YCY-TP) | Switch to PE pairs for RS-422/RS-485 runs |
DIN VDE 0812 Products
Insulation Materials in This Standard
Frequently Asked Questions
- How does LiYCY differ from Li2YCY-TP under DIN VDE 0812?
- LiYCY uses PVC core insulation in layered cores for general control signals, whereas Li2YCY-TP uses polyethylene (PE) insulated twisted pairs to lower mutual capacitance for RS-422/RS-485 data links.
- When are LiHCH or LiY11Y specified instead of LiYCY?
- Specify LiHCH where halogen-free, low-smoke fire safety is mandatory (public buildings, transit enclosures), and LiY11Y where mineral oils, coolants or heavy mechanical abrasion would degrade PVC.
- Can DIN VDE 0812 cables like LiYCY be used for mains AC power wiring?
- No. DIN VDE 0812 cables are engineered for low-voltage electronic control, sensor and data circuits (typically 350V–500V peak signal duty) and do not meet fixed building mains power installation codes such as EN 50525 or IEC 60502.
- How should the braided copper screen on LiYCY or Li2YCY-TP be terminated for best EMC performance?
- Terminate the tinned-copper braid with full 360° circumferential contact using metallic EMC cable glands or shield-clamp rails at the cabinet entry; twisting the braid into a long pigtail adds inductance that severely degrades high-frequency VFD noise rejection.