Industrial Fieldbus Cables

Impedance-controlled 120 Ω and 150 Ω shielded twisted-pair cables for CAN, CAN FD, RS-485, Modbus and L2 industrial networks — across fixed PVC, drag-chain halogen-free PUR and UV-resistant outdoor PE sheaths.

Impedance-matched cabling for industrial serial networks

Differential fieldbus networks in factory automation, distributed PLC I/O, motion drives, solar farms and SCADA plants transmit high-frequency digital signals over long runs alongside switching drives and contactors. General-purpose control cable introduces excessive mutual capacitance and uncontrolled characteristic impedance, resulting in signal reflections and bit errors at elevated baud rates.

Purpose-built fieldbus cables solve this with low-permittivity cellular (foam) polyethylene core insulation, precision pair lay lengths and high-coverage EMC screening. For 120 Ω ISO 11898-2 CAN and TIA/EIA-485-A / Modbus links, constructions span indoor flame-retardant PVC trunks, continuous-flex fine-stranded halogen-free PUR cables for moving drag chains, and carbon-black UV- and moisture-resistant PE sheaths for permanent outdoor solar, energy-storage and utility installations.

For 150 Ω IEC 61158-2 L2 fieldbus networks, solid-conductor PVC designs support rapid fixed-installation connector termination while fine-stranded halogen-free PUR variants handle continuous motion in cable carriers, alongside custom hybrid power-plus-serial builds.

Industrial Fieldbus Products

  • BUS CAN — ISO 11898-2 · Foam PE / PVC · -40°C to +80°C · 250V
  • BUS CAN FD — ISO 11898-2 · Foam PE / PUR/TPU · -40°C to +80°C · 250V
  • BUS L2-150 — IEC 61158-2 · Foam PE / PVC · -40°C to +80°C · 250V
  • BUS L2-150 FD — IEC 61158-2 · Foam PE / PUR/TPU · -40°C to +80°C · 250V
  • BUS RS-485 — TIA/EIA-485-A · Foam PE / PVC · -30°C to +80°C · 300V
  • BUS RS-485 FD — TIA/EIA-485-A · Foam PE / PUR/TPU · -40°C to +80°C · 300V
  • BUS RS-485 OUTDOOR — TIA/EIA-485-A · Foam PE / PE · -40°C to +80°C · 300V

Related Standards, Materials & Applications

Frequently Asked Questions

When should I specify continuous-flex (FD) PUR fieldbus cable instead of standard PVC?
Specify drag-chain FD PUR variants whenever the cable moves inside energy chains, gantries or articulated machinery, or where oil, coolant and halogen-free resistance are required. Use standard PVC fieldbus cables for stationary cabinet, tray and indoor trunk routing.
What fieldbus jacket is best for outdoor solar PV, energy storage or SCADA trunks?
Select carbon-black UV- and moisture-resistant polyethylene (PE) outer jacketing paired with cellular PE cores and foil-plus-braid EMC screening for permanent outdoor exposure, damp ducts and long-haul utility runs.
Why do 120 Ω and 150 Ω fieldbus cables use cellular (foam) PE insulation?
Foaming polyethylene introduces microscopic gas cells that lower the dielectric constant and mutual pair capacitance roughly in half compared with PVC, preserving crisp digital waveforms over extended trunk distances.
How do industrial fieldbus cables differ from automotive SAE J1939 CAN-Bus cables?
SAE J1939 cables are engineered for mobile vehicle harnesses facing engine-bay heat (125°C–150°C) and automotive fluids, whereas industrial fieldbus cables are optimised for factory cabinets, cable trays, drag chains, outdoor utility trunks and industrial bus connectors.