Industrial Fieldbus Cables
Impedance-controlled 120 Ω and 150 Ω shielded twisted-pair cables for CAN, CAN FD, RS-485, Modbus and L2 industrial networks — across fixed PVC, drag-chain halogen-free PUR and UV-resistant outdoor PE sheaths.
Impedance-matched cabling for industrial serial networks
Differential fieldbus networks in factory automation, distributed PLC I/O, motion drives, solar farms and SCADA plants transmit high-frequency digital signals over long runs alongside switching drives and contactors. General-purpose control cable introduces excessive mutual capacitance and uncontrolled characteristic impedance, resulting in signal reflections and bit errors at elevated baud rates.
Purpose-built fieldbus cables solve this with low-permittivity cellular (foam) polyethylene core insulation, precision pair lay lengths and high-coverage EMC screening. For 120 Ω ISO 11898-2 CAN and TIA/EIA-485-A / Modbus links, constructions span indoor flame-retardant PVC trunks, continuous-flex fine-stranded halogen-free PUR cables for moving drag chains, and carbon-black UV- and moisture-resistant PE sheaths for permanent outdoor solar, energy-storage and utility installations.
For 150 Ω IEC 61158-2 L2 fieldbus networks, solid-conductor PVC designs support rapid fixed-installation connector termination while fine-stranded halogen-free PUR variants handle continuous motion in cable carriers, alongside custom hybrid power-plus-serial builds.
Industrial Fieldbus Products
- BUS CAN — ISO 11898-2 · Foam PE / PVC · -40°C to +80°C · 250V
- BUS CAN FD — ISO 11898-2 · Foam PE / PUR/TPU · -40°C to +80°C · 250V
- BUS L2-150 — IEC 61158-2 · Foam PE / PVC · -40°C to +80°C · 250V
- BUS L2-150 FD — IEC 61158-2 · Foam PE / PUR/TPU · -40°C to +80°C · 250V
- BUS RS-485 — TIA/EIA-485-A · Foam PE / PVC · -30°C to +80°C · 300V
- BUS RS-485 FD — TIA/EIA-485-A · Foam PE / PUR/TPU · -40°C to +80°C · 300V
- BUS RS-485 OUTDOOR — TIA/EIA-485-A · Foam PE / PE · -40°C to +80°C · 300V
Related Standards, Materials & Applications
Frequently Asked Questions
- When should I specify continuous-flex (FD) PUR fieldbus cable instead of standard PVC?
- Specify drag-chain FD PUR variants whenever the cable moves inside energy chains, gantries or articulated machinery, or where oil, coolant and halogen-free resistance are required. Use standard PVC fieldbus cables for stationary cabinet, tray and indoor trunk routing.
- What fieldbus jacket is best for outdoor solar PV, energy storage or SCADA trunks?
- Select carbon-black UV- and moisture-resistant polyethylene (PE) outer jacketing paired with cellular PE cores and foil-plus-braid EMC screening for permanent outdoor exposure, damp ducts and long-haul utility runs.
- Why do 120 Ω and 150 Ω fieldbus cables use cellular (foam) PE insulation?
- Foaming polyethylene introduces microscopic gas cells that lower the dielectric constant and mutual pair capacitance roughly in half compared with PVC, preserving crisp digital waveforms over extended trunk distances.
- How do industrial fieldbus cables differ from automotive SAE J1939 CAN-Bus cables?
- SAE J1939 cables are engineered for mobile vehicle harnesses facing engine-bay heat (125°C–150°C) and automotive fluids, whereas industrial fieldbus cables are optimised for factory cabinets, cable trays, drag chains, outdoor utility trunks and industrial bus connectors.