BUS CAN FD
BUS CAN FD is a CASMO industrial fieldbus cable for Industrial Fieldbus. Foam PE insulated, -40°C to +80°C, 250V. 120 Ω continuous-flex drag-chain (FD) industrial CAN, CANopen and CAN FD bus cable with 19-strand bare copper conductors, cellular PE insulation, tinned-copper braid shield and oil-re…
120 Ω continuous-flex drag-chain (FD) industrial CAN, CANopen and CAN FD bus cable with 19-strand bare copper conductors, cellular PE insulation, tinned-copper braid shield and oil-resistant halogen-free violet PUR sheath.
Key Ratings
- BUS CAN FD: · Temperature -40°C to +80°C · Rated Voltage 250V · Test Voltage 1500V
Construction
- Conductor
- Bare Copper · Flexible Stranded
- Core Insulation
- Foamed · Foam PE
- Cabling
- Twisted
- Core Identification
- 1×2: White / Brown; 2×2: White / Brown, Green / Yellow (DIN 47100)
- Shield
- Braid · Tinned copper braid
- Jacket
- Extruded · PUR/TPU
Characteristics
- Continuous Flexing Temperature: -30°C to +70°C
- Characteristic Impedance: 120 Ω ± 12 Ω (at 1 MHz)
- Mutual Capacitance: Approx. 40 nF/km (at 800 Hz)
- Velocity of Propagation: Approx. 76%
- Continuous-Flex Durability: Designed to withstand repeated bending cycles in cable carriers and continuously moving machinery.
- Oil Resistance: Resistant to oil exposure, helping maintain the integrity of the cable covering in oily environments.
- Abrasion Resistance: Resistant to abrasion, helping protect the cable surface against wear caused by rubbing and handling.
- EMC Interference Shielding: Metallic shielding helps suppress electromagnetic interference and maintain signal integrity in electrically noisy environments.
Applications
- Cable Carriers and Moving Machinery: For dynamic signal and control routing in drag chains, gantries, linear axes and automated handling equipment.
- Fieldbus and Serial Data Networks: For differential serial and fieldbus communication links between programmable controllers, distributed I/O modules, drives and field devices.
Standards & Compliance
- Standard: ISO 11898-2
- Fire Performance: FT2
- RoHS: Compliant
- REACH: Compliant
Specification Data
| CASMO Part No. | Conductor Size (mm²) | No. Of Strands | Nom. Strand Dia. (mm) | Nom. Ins. Thickness (mm) | Nom. Core O.D. (mm) | Min. Braid Coverage (%) | Nom. Jkt. Thickness (mm) | Nom. O.D. (mm) | Max. DCR @20°C (Ω/km) |
|---|---|---|---|---|---|---|---|---|---|
| 1230020.25/19-1P-AS-VT | 1×2×0.25 | 19 | 0.13 | 0.55 | 1.75 | 80 | 0.95 | 6.4 | 79.8 |
| 1230020.25/19-2P-AS-VT | 2×2×0.25 | 19 | 0.13 | 0.55 | 1.75 | 80 | 1.10 | 7.8 | 79.8 |
| 1230020.34/19-1P-AS-VT | 1×2×0.34 | 19 | 0.15 | 0.62 | 2.00 | 80 | 1.00 | 6.9 | 61.0 |
| 1230020.34/19-2P-AS-VT | 2×2×0.34 | 19 | 0.15 | 0.62 | 2.00 | 80 | 1.15 | 8.6 | 61.0 |
| 1230020.5/19-1P-AS-VT | 1×2×0.5 | 19 | 0.18 | 0.75 | 2.40 | 80 | 1.10 | 8.0 | 40.5 |
| 1230020.5/19-2P-AS-VT | 2×2×0.5 | 19 | 0.18 | 0.75 | 2.40 | 80 | 1.25 | 10.0 | 40.5 |
* "-AS-" = 19-strand flexible bare copper conductor for continuous-flex drag-chain (FD) service; "-1P" / "-2P" = number of twisted pairs; "-VT" = violet (RAL 4001) PUR outer sheath (standard). † Max. DCR @20°C is specified per single conductor; maximum DC loop resistance equals 2 × single-conductor DCR (159.6 / 122.0 / 81.0 Ω/km for 0.25 / 0.34 / 0.5 mm²). Compatible with Classical CAN, CANopen, and CAN FD physical layers (ISO 11898-2). ‡ Standard halogen-free PUR jacket meets FT2 flame rating; low-halogen VW-1 / FT1 jacket available upon request.
- "-AS-" = 19-strand flexible bare copper conductor for continuous-flex drag-chain (FD) service; "-1P" / "-2P" = number of twisted pairs; "-VT" = violet (RAL 4001) PUR outer sheath (standard).
- Max. DCR @20°C is specified per single conductor; maximum DC loop resistance equals 2 × single-conductor DCR (159.6 / 122.0 / 81.0 Ω/km for 0.25 / 0.34 / 0.5 mm²). Compatible with Classical CAN, CANopen, and CAN FD physical layers (ISO 11898-2).
- Standard halogen-free PUR jacket meets FT2 flame rating; low-halogen VW-1 / FT1 jacket available upon request.