ISO 11898-2 — Road Vehicles Controller Area Network High-Speed Medium Access Unit

International physical-layer standard specifying 120 Ω differential twisted-pair transmission media for Classical CAN up to 1 Mbit/s and CAN FD up to 5–8 Mbit/s.

Standard · International Organization for Standardization

What is ISO 11898-2?

This standard defines the high-speed physical media attachment for Controller Area Network serial buses across industrial automation, CANopen machine networks, mobile hydraulics, energy storage racks, and commercial vehicles. To suppress signal reflections at fast transceiver edges and reject common-mode electromagnetic noise from variable-frequency drives and servo inverters, the bus requires a balanced differential twisted pair with a nominal characteristic impedance of 120 Ω.

Industrial bus cables built for fixed cabinet routing or continuous drag-chain motion pair low-permittivity foamed polyolefin core insulation with controlled pair lay lengths, 100% aluminum/polyester foil plus high-coverage tinned-copper braid shielding, and oil- or halogen-free outer jackets such as PUR or FRNC/LSZH. Termination resistors of 120 Ω at both ends of the linear trunk match the cable impedance and maintain eye-diagram margin across long factory runs.

Key Technical Requirements

ParameterRequirementNotes
Characteristic impedance120 Ω nominal (±12 Ω typical)Measured across 1 MHz high-speed CAN passband
Mutual capacitanceLow pair capacitance, typically ≤ 40–45 pF/mMinimizes capacitive bus loading and edge rounding
Conductor gauges24 AWG / 0.25 mm² · 22 AWG / 0.34–0.50 mm² · 20 AWG / 0.75 mm²Scaled to trunk length and loop resistance budget
EMI shieldingOverall Al/PET foil + ≥80%–85% tinned-copper braidLow transfer impedance against VFD switching transients
Protocol ecosystemsClassical CAN · CAN FD · CANopen · DeviceNet trunk/dropShared 120 Ω differential physical layer

ISO 11898-2 Products

  • BUS CAN — ISO 11898-2 · Foam PE / PVC · -40°C to +80°C · 250V
  • BUS CAN FD — ISO 11898-2 · Foam PE / PUR/TPU · -40°C to +80°C · 250V

Insulation Materials in This Standard

Frequently Asked Questions

Why cannot ordinary 60 Ω–85 Ω PVC control wire be used for CAN FD networks?
Standard PVC twisted pairs have high dielectric permittivity, excessive capacitance, and ~70 Ω impedance, causing severe impedance reflections and bit-timing errors against 120 Ω bus terminations—especially at 2–5 Mbit/s CAN FD data rates.
How do I choose between 0.25 mm², 0.50 mm², and 0.75 mm² CAN cables?
Select 0.25 mm² or 24 AWG for short cabinet trunks and sensor drops up to ~40 m, 0.34–0.50 mm² or 22 AWG for general machine trunks up to 100–250 m, and 0.75 mm² for extended trunks where DC loop resistance governs voltage drop.
When is a continuous-flex PUR jacket required on a CAN bus cable?
Specify fine-stranded conductors with a matte PUR outer jacket whenever the bus traverses robotic dress packs, gantry cable carriers, or oily machine-tool zones.