BUS RS-485 FD

BUS RS-485 FD is a CASMO industrial fieldbus cable for Industrial Fieldbus. Foam PE insulated, -40°C to +80°C, 300V. 120 Ω continuous-flex drag-chain RS-485 and Modbus serial cable with 19-strand tinned-copper conductors, cellular PE twisted pairs, dual foil-plus-braid EMC shielding and halogen-f…

120 Ω continuous-flex drag-chain RS-485 and Modbus serial cable with 19-strand tinned-copper conductors, cellular PE twisted pairs, dual foil-plus-braid EMC shielding and halogen-free grey PUR sheath.

Key Ratings

  • BUS RS-485 FD: · Temperature -40°C to +80°C · Rated Voltage 300V · Test Voltage 1500V

Construction

Conductor
Tinned Copper · Flexible Stranded
Core Insulation
Foamed · Foam PE
Cabling
Twisted
Core Identification
Pair 1: White/Blue Stripe & Blue/White Stripe; Pair 2: White/Orange Stripe & Orange/White Stripe; Pair 3: White/Green Stripe & Green/White Stripe; Pair 4: White/Brown Stripe & Brown/White Stripe
Shield
Foil · Aluminum/polyester (Al/PET) foil
Drain Wire
Stranded Tinned Copper
Shield
Braid · Tinned copper braid
Jacket
Extruded · PUR/TPU

Characteristics

  • Continuous Flexing Temperature: -30°C to +70°C
  • Characteristic Impedance: 120 Ω ± 12 Ω (at 1 MHz)
  • Mutual Capacitance: Approx. 42 nF/km (conductor to conductor at 1 kHz)
  • Velocity of Propagation: Approx. 78%
  • Continuous-Flex Durability: Designed to withstand repeated bending cycles in cable carriers and continuously moving machinery.
  • Oil Resistance: Resistant to oil exposure, helping maintain the integrity of the cable covering in oily environments.
  • Abrasion Resistance: Resistant to abrasion, helping protect the cable surface against wear caused by rubbing and handling.
  • EMC Interference Shielding: Metallic shielding helps suppress electromagnetic interference and maintain signal integrity in electrically noisy environments.

Applications

  • Cable Carriers and Moving Machinery: For dynamic signal and control routing in drag chains, gantries, linear axes and automated handling equipment.
  • Fieldbus and Serial Data Networks: For differential serial and fieldbus communication links between programmable controllers, distributed I/O modules, drives and field devices.

Standards & Compliance

  • Standard: TIA/EIA-485-A
  • Fire Performance: FT2
  • RoHS: Compliant
  • REACH: Compliant

Specification Data

CASMO Part No.Conductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Ins. Thickness (mm)Nom. Core O.D. (mm)Min. Braid Coverage (%)Nom. Jkt. Thickness (mm)Nom. O.D. (mm)Max. DCR @20°C (Ω/km)
12300624/19-1P-TS-GY1P×24190.130.551.75800.956.284.0
12300624/19-2P-TS-GY2P×24190.130.551.75801.108.884.0
12300624/19-3P-TS-GY3P×24190.130.551.75801.159.584.0
12300624/19-4P-TS-GY4P×24190.130.551.75801.2010.484.0
12300622/19-1P-TS-GY1P×22190.160.652.10801.057.455.5
12300622/19-2P-TS-GY2P×22190.160.652.10801.159.655.5
12300622/19-3P-TS-GY3P×22190.160.652.10801.2010.455.5
12300622/19-4P-TS-GY4P×22190.160.652.10801.2511.455.5

* "-TS-" = 19-strand flexible tinned copper conductor for drag-chain (FD) service; "-1P" to "-4P" = number of twisted pairs; "-GY" = grey PUR outer sheath (standard). † Max. DCR @20°C is specified as guaranteed single-conductor maximum; maximum DC loop resistance equals 2 × single-conductor DCR (168.0 Ω/km for 24 AWG; 111.0 Ω/km for 22 AWG). ‡ Standard halogen-free PUR jacket meets FT2 flame rating; low-halogen VW-1 / FT1 jacket available upon request.

  • "-TS-" = 19-strand flexible tinned copper conductor for drag-chain (FD) service; "-1P" to "-4P" = number of twisted pairs; "-GY" = grey PUR outer sheath (standard).
  • Max. DCR @20°C is specified as guaranteed single-conductor maximum; maximum DC loop resistance equals 2 × single-conductor DCR (168.0 Ω/km for 24 AWG; 111.0 Ω/km for 22 AWG).
  • Standard halogen-free PUR jacket meets FT2 flame rating; low-halogen VW-1 / FT1 jacket available upon request.