BUS RS-485 FD
BUS RS-485 FD is a CASMO industrial fieldbus cable for Industrial Fieldbus. Foam PE insulated, -40°C to +80°C, 300V. 120 Ω continuous-flex drag-chain RS-485 and Modbus serial cable with 19-strand tinned-copper conductors, cellular PE twisted pairs, dual foil-plus-braid EMC shielding and halogen-f…
120 Ω continuous-flex drag-chain RS-485 and Modbus serial cable with 19-strand tinned-copper conductors, cellular PE twisted pairs, dual foil-plus-braid EMC shielding and halogen-free grey PUR sheath.
Key Ratings
- BUS RS-485 FD: · Temperature -40°C to +80°C · Rated Voltage 300V · Test Voltage 1500V
Construction
- Conductor
- Tinned Copper · Flexible Stranded
- Core Insulation
- Foamed · Foam PE
- Cabling
- Twisted
- Core Identification
- Pair 1: White/Blue Stripe & Blue/White Stripe; Pair 2: White/Orange Stripe & Orange/White Stripe; Pair 3: White/Green Stripe & Green/White Stripe; Pair 4: White/Brown Stripe & Brown/White Stripe
- Shield
- Foil · Aluminum/polyester (Al/PET) foil
- Drain Wire
- Stranded Tinned Copper
- Shield
- Braid · Tinned copper braid
- Jacket
- Extruded · PUR/TPU
Characteristics
- Continuous Flexing Temperature: -30°C to +70°C
- Characteristic Impedance: 120 Ω ± 12 Ω (at 1 MHz)
- Mutual Capacitance: Approx. 42 nF/km (conductor to conductor at 1 kHz)
- Velocity of Propagation: Approx. 78%
- Continuous-Flex Durability: Designed to withstand repeated bending cycles in cable carriers and continuously moving machinery.
- Oil Resistance: Resistant to oil exposure, helping maintain the integrity of the cable covering in oily environments.
- Abrasion Resistance: Resistant to abrasion, helping protect the cable surface against wear caused by rubbing and handling.
- EMC Interference Shielding: Metallic shielding helps suppress electromagnetic interference and maintain signal integrity in electrically noisy environments.
Applications
- Cable Carriers and Moving Machinery: For dynamic signal and control routing in drag chains, gantries, linear axes and automated handling equipment.
- Fieldbus and Serial Data Networks: For differential serial and fieldbus communication links between programmable controllers, distributed I/O modules, drives and field devices.
Standards & Compliance
- Standard: TIA/EIA-485-A
- Fire Performance: FT2
- RoHS: Compliant
- REACH: Compliant
Specification Data
| CASMO Part No. | Conductor Size (AWG) | No. Of Strands | Nom. Strand Dia. (mm) | Nom. Ins. Thickness (mm) | Nom. Core O.D. (mm) | Min. Braid Coverage (%) | Nom. Jkt. Thickness (mm) | Nom. O.D. (mm) | Max. DCR @20°C (Ω/km) |
|---|---|---|---|---|---|---|---|---|---|
| 12300624/19-1P-TS-GY | 1P×24 | 19 | 0.13 | 0.55 | 1.75 | 80 | 0.95 | 6.2 | 84.0 |
| 12300624/19-2P-TS-GY | 2P×24 | 19 | 0.13 | 0.55 | 1.75 | 80 | 1.10 | 8.8 | 84.0 |
| 12300624/19-3P-TS-GY | 3P×24 | 19 | 0.13 | 0.55 | 1.75 | 80 | 1.15 | 9.5 | 84.0 |
| 12300624/19-4P-TS-GY | 4P×24 | 19 | 0.13 | 0.55 | 1.75 | 80 | 1.20 | 10.4 | 84.0 |
| 12300622/19-1P-TS-GY | 1P×22 | 19 | 0.16 | 0.65 | 2.10 | 80 | 1.05 | 7.4 | 55.5 |
| 12300622/19-2P-TS-GY | 2P×22 | 19 | 0.16 | 0.65 | 2.10 | 80 | 1.15 | 9.6 | 55.5 |
| 12300622/19-3P-TS-GY | 3P×22 | 19 | 0.16 | 0.65 | 2.10 | 80 | 1.20 | 10.4 | 55.5 |
| 12300622/19-4P-TS-GY | 4P×22 | 19 | 0.16 | 0.65 | 2.10 | 80 | 1.25 | 11.4 | 55.5 |
* "-TS-" = 19-strand flexible tinned copper conductor for drag-chain (FD) service; "-1P" to "-4P" = number of twisted pairs; "-GY" = grey PUR outer sheath (standard). † Max. DCR @20°C is specified as guaranteed single-conductor maximum; maximum DC loop resistance equals 2 × single-conductor DCR (168.0 Ω/km for 24 AWG; 111.0 Ω/km for 22 AWG). ‡ Standard halogen-free PUR jacket meets FT2 flame rating; low-halogen VW-1 / FT1 jacket available upon request.
- "-TS-" = 19-strand flexible tinned copper conductor for drag-chain (FD) service; "-1P" to "-4P" = number of twisted pairs; "-GY" = grey PUR outer sheath (standard).
- Max. DCR @20°C is specified as guaranteed single-conductor maximum; maximum DC loop resistance equals 2 × single-conductor DCR (168.0 Ω/km for 24 AWG; 111.0 Ω/km for 22 AWG).
- Standard halogen-free PUR jacket meets FT2 flame rating; low-halogen VW-1 / FT1 jacket available upon request.