BUS RS-485 OUTDOOR

BUS RS-485 OUTDOOR is a CASMO industrial fieldbus cable for Industrial Fieldbus. Foam PE insulated, -40°C to +80°C, 300V. 120 Ω outdoor UV- and moisture-resistant RS-485 and SCADA serial trunk cable in 24, 22 and 18 AWG with cellular PE twisted pairs, dual foil-plus-braid EMC shielding and black …

120 Ω outdoor UV- and moisture-resistant RS-485 and SCADA serial trunk cable in 24, 22 and 18 AWG with cellular PE twisted pairs, dual foil-plus-braid EMC shielding and black PE outer sheath.

Key Ratings

  • BUS RS-485 OUTDOOR: · Temperature -40°C to +80°C · Rated Voltage 300V · Test Voltage 1500V

Construction

Conductor
Tinned Copper · Stranded
Core Insulation
Foamed · Foam PE
Cabling
Twisted
Core Identification
Pair 1: White/Blue Stripe & Blue/White Stripe; Pair 2: White/Orange Stripe & Orange/White Stripe
Shield
Foil · Aluminum/polyester (Al/PET) foil
Drain Wire
Stranded Tinned Copper
Shield
Braid · Tinned copper braid
Jacket
Extruded · PE

Characteristics

  • Min. Installation Temperature: -20°C
  • Characteristic Impedance: 120 Ω ± 12 Ω (at 1 MHz)
  • Mutual Capacitance: Approx. 40 nF/km (conductor to conductor at 1 kHz)
  • Velocity of Propagation: Approx. 78%
  • UV Resistance: Resistant to ultraviolet exposure, helping reduce surface deterioration caused by sunlight.
  • Weather Resistance: Resistant to weathering, helping maintain cable integrity under exposure to sunlight, moisture and changing weather conditions.
  • Moisture Resistance: Resistant to moisture and humidity, helping maintain the integrity of the cable covering in damp environments.
  • EMC Interference Shielding: Metallic shielding helps suppress electromagnetic interference and maintain signal integrity in electrically noisy environments.

Applications

  • Outdoor Renewable and Utility Telemetry: For outdoor serial data and telemetry links across solar arrays, energy storage yards, substations and remote monitoring stations.
  • Fieldbus and Serial Data Networks: For differential serial and fieldbus communication links between programmable controllers, distributed I/O modules, drives and field devices.

Standards & Compliance

  • Standard: TIA/EIA-485-A
  • RoHS: Compliant
  • REACH: Compliant

Specification Data

CASMO Part No.Conductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Ins. Thickness (mm)Nom. Core O.D. (mm)Min. Braid Coverage (%)Nom. Jkt. Thickness (mm)Nom. O.D. (mm)Max. DCR @20°C (Ω/km)
12300724/7-1P-TS-BK1P×2470.200.551.70801.006.194.2
12300724/7-2P-TS-BK2P×2470.200.551.70801.208.894.2
12300722/7-1P-TS-BK1P×2270.250.652.05801.107.459.4
12300722/7-2P-TS-BK2P×2270.250.652.05801.259.659.4
12300718/16-1P-TS-BK1P×18160.250.802.80801.208.926.0
12300718/16-2P-TS-BK2P×18160.250.802.80801.3511.826.0

* "-TS-" = stranded tinned copper conductor; "-1P" / "-2P" = number of twisted pairs; "-BK" = UV-stabilized black PE outer sheath (standard). † Max. DCR @20°C is specified as guaranteed single-conductor maximum; maximum DC loop resistance equals 2 × single-conductor DCR (188.4 / 118.8 / 52.0 Ω/km for 24 / 22 / 18 AWG). Standard black PE outer sheath is designed for outdoor UV/moisture resistance and is not flame-retardant.

  • "-TS-" = stranded tinned copper conductor; "-1P" / "-2P" = number of twisted pairs; "-BK" = UV-stabilized black PE outer sheath (standard).
  • Max. DCR @20°C is specified as guaranteed single-conductor maximum; maximum DC loop resistance equals 2 × single-conductor DCR (188.4 / 118.8 / 52.0 Ω/km for 24 / 22 / 18 AWG). Standard black PE outer sheath is designed for outdoor UV/moisture resistance and is not flame-retardant.

Related Categories