BUS RS-485

BUS RS-485 is a CASMO industrial fieldbus cable for Industrial Fieldbus. Foam PE insulated, -30°C to +80°C, 300V. 120 Ω low-capacitance 1P–4P industrial RS-485 and Modbus serial data cable with cellular PE twisted pairs, dual foil-plus-braid EMC shielding, drain wire and grey PVC outer sheath.

120 Ω low-capacitance 1P–4P industrial RS-485 and Modbus serial data cable with cellular PE twisted pairs, dual foil-plus-braid EMC shielding, drain wire and grey PVC outer sheath.

Key Ratings

  • BUS RS-485: · Temperature -30°C to +80°C · Rated Voltage 300V · Test Voltage 1500V

Construction

Conductor
Tinned Copper · Stranded
Core Insulation
Foamed · Foam PE
Cabling
Twisted
Core Identification
Pair 1: White/Blue Stripe & Blue/White Stripe; Pair 2: White/Orange Stripe & Orange/White Stripe; Pair 3: White/Green Stripe & Green/White Stripe; Pair 4: White/Brown Stripe & Brown/White Stripe
Shield
Foil · Aluminum/polyester (Al/PET) foil
Drain Wire
Stranded Tinned Copper
Shield
Braid · Tinned copper braid
Jacket
Extruded · PVC

Characteristics

  • Occasional Flexing / Installation Temperature: -5°C to +70°C
  • Characteristic Impedance: 120 Ω ± 12 Ω (at 1 MHz)
  • Mutual Capacitance: Approx. 42 nF/km (conductor to conductor at 1 kHz)
  • Velocity of Propagation: Approx. 78%
  • Low-Capacitance Signal Integrity: Low-capacitance insulation and balanced pair twist help limit signal attenuation across extended transmission distances.
  • EMC Interference Shielding: Metallic shielding helps suppress electromagnetic interference and maintain signal integrity in electrically noisy environments.
  • Mechanical Strength: Provides mechanical strength to withstand handling and installation stresses and help maintain cable integrity.

Applications

  • Fieldbus and Serial Data Networks: For differential serial and fieldbus communication links between programmable controllers, distributed I/O modules, drives and field devices.
  • Sensors and Instrumentation: For connections between sensors, measuring instruments and associated control equipment.

Standards & Compliance

  • Standard: TIA/EIA-485-A
  • Fire Performance: IEC 60332-1-2
  • RoHS: Compliant
  • REACH: Compliant

Specification Data

CASMO Part No.Conductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Ins. Thickness (mm)Nom. Core O.D. (mm)Min. Braid Coverage (%)Nom. Jkt. Thickness (mm)Nom. O.D. (mm)Max. DCR @20°C (Ω/km)
12300524/7-1P-TS-GY1P×2470.200.551.70800.905.994.2
12300524/7-2P-TS-GY2P×2470.200.551.70801.108.694.2
12300524/7-3P-TS-GY3P×2470.200.551.70801.159.294.2
12300524/7-4P-TS-GY4P×2470.200.551.70801.2010.194.2
12300522/7-1P-TS-GY1P×2270.250.652.05801.007.259.4
12300522/7-2P-TS-GY2P×2270.250.652.05801.159.459.4
12300522/7-3P-TS-GY3P×2270.250.652.05801.2010.159.4
12300522/7-4P-TS-GY4P×2270.250.652.05801.2511.159.4

* "-TS-" = stranded tinned copper conductor; "-1P" to "-4P" = number of twisted pairs; "-GY" = grey PVC outer sheath (standard). † Max. DCR @20°C is specified as guaranteed single-conductor maximum per ASTM B33 / UL 1581 (not nominal); maximum DC loop resistance equals 2 × single-conductor DCR (188.4 Ω/km for 24 AWG; 118.8 Ω/km for 22 AWG).

  • "-TS-" = stranded tinned copper conductor; "-1P" to "-4P" = number of twisted pairs; "-GY" = grey PVC outer sheath (standard).
  • Max. DCR @20°C is specified as guaranteed single-conductor maximum per ASTM B33 / UL 1581 (not nominal); maximum DC loop resistance equals 2 × single-conductor DCR (188.4 Ω/km for 24 AWG; 118.8 Ω/km for 22 AWG).