RTD-APA is a CASMO rtd cable for RTD / PT100 Cable. PFA insulated, -65°C to +260°C. 3-core stranded 2% nickel-plated copper RTD / PT100 cable with extruded PFA cores, internal 2% nickel-plated copper braid EMI shield, and extruded PFA outer jacket (-65°C to +260°C).

3-core stranded 2% nickel-plated copper RTD / PT100 cable with extruded PFA cores, internal 2% nickel-plated copper braid EMI shield, and extruded PFA outer jacket (-65°C to +260°C).

Key Ratings

  • RTD-APA: · Temperature -65°C to +260°C

Construction

Conductor
Nickel Plated Copper · Stranded
Core Insulation
Extruded · PFA
Cabling
Laid Up · 3-core concentric twist
Core Identification
3-wire IEC 60751 color code (2 Red + 1 White)
Shield
Braid · 2% Nickel-plated copper braid (≥85%)
Jacket
Extruded · PFA

Characteristics

  • Signal Circuit Duty: Low-voltage RTD excitation and bridge measurement signal circuits only (not rated for mains power distribution); extruded core insulation is factory dielectric-verified at 1000 V AC for 1 min.
  • Low-Resistance Lead Compensation: Matched three-conductor copper construction minimizes lead-wire resistance imbalance in bridge-connected RTD circuits.
  • EMC Interference Shielding: Metallic shielding helps suppress electromagnetic interference and maintain signal integrity in electrically noisy environments.
  • High-Temperature Thermal Stability: Heat-resistant insulation and jacketing resist thermal aging, embrittlement and cut-through in elevated-temperature zones.
  • Chemical Resistance: Resistant to chemical exposure, helping protect the cable covering against deterioration in chemically demanding environments.

Applications

  • PT100 and RTD Resistance Thermometry: For three-wire resistance thermometer lead connections between RTD sensors, transmitters and temperature controllers.
  • Autoclaves, Cryogenic Chambers and Test Rigs: For precision thermal profiling in aerospace autoclaves, environmental test chambers, semiconductor tools and laboratory instrumentation.
  • Sensors and Instrumentation: For connections between sensors, measuring instruments and associated control equipment.

Standards & Compliance

  • Standard: IEC 60751
  • RoHS: Compliant
  • REACH: Compliant

RTD-APA — 3-Core PFA Insulated, NPC Shielded & PFA 260°C RTD Cable

CASMO Part No.Total CoresConductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Nom. Core O.D. (mm)Nom. Shield Thickness (mm)Nom. Jkt. Thickness (mm)Nom. O.D. (mm)O.D. Tolerance ± (mm)
710403C26-NS-XX32670.160.480.20.90.20.53.30.2
710403C24-NS-XX32470.20.60.21.00.20.53.60.2
710403C22-NS-XX32270.2540.760.21.20.20.54.00.2
710403C20-NS-XX32070.320.960.21.40.20.54.40.2
710403C18-NS-XX31870.391.170.251.70.20.55.10.3
710403C16-NS-XX316190.31.50.252.00.20.55.70.3
710403C14-NS-XX314190.371.850.252.40.20.56.60.3

* "-NS-" = stranded 2% nickel-plated copper conductor with 2% nickel-plated copper braid EMI shield (standard for 260°C PFA RTD cable). Standard 3-core IEC 60751 configuration (2 Red + 1 White); 2-core (2C) and 4-core (4C) constructions available upon request. † "-XX" = outer jacket color code: RD Red (standard), WH White, BK Black, or GY Grey (3-core identification per Color Code Chart below).

  • "-NS-" = stranded 2% nickel-plated copper conductor with 2% nickel-plated copper braid EMI shield (standard for 260°C PFA RTD cable). Standard 3-core IEC 60751 configuration (2 Red + 1 White); 2-core (2C) and 4-core (4C) constructions available upon request.
  • "-XX" = outer jacket color code: RD Red (standard), WH White, BK Black, or GY Grey (3-core identification per Color Code Chart below).

Color Code Chart

  • Red (Lead A)
  • Red (Lead A')
  • White (Sense B)

Related Categories