TC-AGG

TC-AGG is a CASMO thermocouple wire for Thermocouple Wire. PFA insulated, -65°C to +260°C. 2-core parallel flat thermocouple cable with extruded PFA primary core insulation, secondary fiberglass core braid, and fiberglass overall braid (-65°C to +260°C).

2-core parallel flat thermocouple cable with extruded PFA primary core insulation, secondary fiberglass core braid, and fiberglass overall braid (-65°C to +260°C).

Key Ratings

  • TC-AGG: · Temperature -65°C to +260°C

Construction

Conductor
Thermocouple Alloy (Type K / J / T / E / N) or Extension / Compensating Alloy (Type KX / JX / TX / EX / NX / RX / SX) · Stranded
Core Insulation
Extruded · PFA
Secondary Core Insulation
Braided · Fiberglass secondary core layer
Cabling
Parallel · Duplex parallel flat core pair
Core Identification
Color-coded per IEC 60584-3 (Type K/KX: +Green / -White) or ASTM E230 on request
Jacket
Braided · Fiberglass

Characteristics

  • EMF Calibration Span: Insulation rated to +260°C continuous; extension-grade alloys (-KX-/-JX-/-EX-/-NX-/-RX-/-SX-) are EMF-calibrated up to +200°C (-TX- up to +100°C). Specify thermocouple-grade alloys (-K-/-J-/-E-/-N-) above +200°C.
  • Signal Circuit Duty: Low-voltage thermoelectric millivolt EMF measurement and extension signal circuits only (not rated for mains power distribution).
  • Calibrated EMF Accuracy: Matched thermoelectric conductor pairs maintain stable electromotive force characteristics across the rated temperature span.
  • High-Temperature Thermal Stability: Heat-resistant insulation and jacketing resist thermal aging, embrittlement and cut-through in elevated-temperature zones.
  • Chemical Resistance: Resistant to chemical exposure, helping protect the cable covering against deterioration in chemically demanding environments.
  • Abrasion Resistance: Resistant to abrasion, helping protect the cable surface against wear caused by rubbing and handling.

Applications

  • Industrial Furnaces, Kilns and Heat Treatment: For temperature measurement and extension wiring on heat-treating furnaces, ceramic kilns, ovens and thermal processing lines.
  • Autoclaves, Cryogenic Chambers and Test Rigs: For precision thermal profiling in aerospace autoclaves, environmental test chambers, semiconductor tools and laboratory instrumentation.
  • Process Temperature Sensing and Pyrometry: For connecting thermocouple probes and cold-junction transmitters across chemical, petrochemical, power-generation and metallurgical plants.

Standards & Compliance

  • Standard: IEC 60584-3 / ASTM E230
  • RoHS: Compliant
  • REACH: Compliant

TC-AGG — PFA + Fiberglass Braided 260°C Duplex Wire

CASMO Part No.Total CoresConductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Nom. Secondary Insulation Wall (mm)Nom. Core O.D. (mm)Nom. Jkt. Thickness (mm)Nom. Overall Width (mm)Overall Width Tolerance ± (mm)Nom. Overall Thickness (mm)Overall Thickness Tolerance ± (mm)
710142C26-KX-XX22670.160.480.20.21.30.23.00.21.70.2
710142C24-KX-XX22470.20.60.20.21.40.23.20.21.80.2
710142C22-KX-XX22270.2540.760.20.21.60.23.60.22.00.2
710142C20-KX-XX22070.320.960.20.21.80.24.00.22.20.2
710142C18-KX-XX21870.391.170.250.22.10.24.60.22.50.2
710142C16-KX-XX216190.31.50.250.22.40.25.20.22.80.2
710142C14-KX-XX214190.371.850.250.22.80.26.00.23.20.2

* "-KX-" = Type KX extension-grade alloy pair (NiCr / NiAl, standard; EMF calibrated up to +200°C). Substitute "-JX-", "-EX-", "-NX-", "-RX-", "-SX-" (EMF calibrated ≤ +200°C), "-TX-" (EMF calibrated ≤ +100°C), or thermocouple-grade "-K-", "-J-", "-T-", "-E-", "-N-" for sensing-junction or > +200°C service (Type T wire-gauge limit: +200°C for 26–20 AWG, +260°C for 16–14 AWG). † "-XX" = color-code suffix: IEC 60584-3 color code supplied as standard (e.g., GN for Type K/KX); ASTM E230 color code available upon request (see Color Code Chart below).

  • "-KX-" = Type KX extension-grade alloy pair (NiCr / NiAl, standard; EMF calibrated up to +200°C). Substitute "-JX-", "-EX-", "-NX-", "-RX-", "-SX-" (EMF calibrated ≤ +200°C), "-TX-" (EMF calibrated ≤ +100°C), or thermocouple-grade "-K-", "-J-", "-T-", "-E-", "-N-" for sensing-junction or > +200°C service (Type T wire-gauge limit: +200°C for 26–20 AWG, +260°C for 16–14 AWG).
  • "-XX" = color-code suffix: IEC 60584-3 color code supplied as standard (e.g., GN for Type K/KX); ASTM E230 color code available upon request (see Color Code Chart below).

Color Code Chart

  • +Green / -White (Jkt: Green)
  • +Black / -White (Jkt: Black)
  • +Brown / -White (Jkt: Brown; TX ≤100°C)
  • +Violet / -White (Jkt: Violet)
  • +Pink / -White (Jkt: Pink)
  • +Orange / -White (Jkt: Orange; ≤100°C)
  • +Yellow / -Red (TC: Brown / Ext: Yellow)
  • +White / -Red (TC: Brown / Ext: Black)
  • +Blue / -Red (TC: Brown / Ext: Blue; TX ≤100°C)
  • +Purple / -Red (TC: Brown / Ext: Purple)
  • +Orange / -Red (TC: Brown / Ext: Orange)
  • +Black / -Red (Ext: Green; ≤200°C)

Related Categories