TC-GGPA

TC-GGPA is a CASMO thermocouple wire for Thermocouple Wire. Fiberglass insulated, -65°C to +260°C. 2-core parallel flat thermocouple cable with fiberglass core insulation, overall fiberglass inner braid, 2% nickel-plated copper braid EMI shield, and extruded PFA outer jacket (-65°C to +260°C).

2-core parallel flat thermocouple cable with fiberglass core insulation, overall fiberglass inner braid, 2% nickel-plated copper braid EMI shield, and extruded PFA outer jacket (-65°C to +260°C).

Key Ratings

  • TC-GGPA: · Temperature -65°C to +260°C

Construction

Conductor
Thermocouple Alloy (Type K / J / T / E / N) or Extension / Compensating Alloy (Type KX / JX / TX / EX / NX / RX / SX) · Stranded
Core Insulation
Braided · Fiberglass
Cabling
Parallel · Duplex parallel flat core pair
Core Identification
Color-coded fiberglass tracer per IEC 60584-3 (Type K/KX: +White w/ Green tracer / -White) or ASTM E230 on request
Inner Braid
Braided · Fiberglass inner braid over parallel core pair
Shield
Braid · 2% Nickel-plated copper braid (≥85%)
Jacket
Extruded · PFA

Characteristics

  • EMF Calibration Span: Insulation rated to +260°C continuous; extension-grade alloys (-KX-/-JX-/-EX-/-NX-/-RX-/-SX-) are EMF-calibrated up to +200°C (-TX- up to +100°C). Specify thermocouple-grade alloys (-K-/-J-/-E-/-N-) above +200°C.
  • Signal Circuit Duty: Low-voltage thermoelectric millivolt EMF measurement and extension signal circuits only (not rated for mains power distribution).
  • Calibrated EMF Accuracy: Matched thermoelectric conductor pairs maintain stable electromotive force characteristics across the rated temperature span.
  • EMC Interference Shielding: Metallic shielding helps suppress electromagnetic interference and maintain signal integrity in electrically noisy environments.
  • High-Temperature Thermal Stability: Heat-resistant insulation and jacketing resist thermal aging, embrittlement and cut-through in elevated-temperature zones.
  • Chemical Resistance: Resistant to chemical exposure, helping protect the cable covering against deterioration in chemically demanding environments.

Applications

  • Process Temperature Sensing and Pyrometry: For connecting thermocouple probes and cold-junction transmitters across chemical, petrochemical, power-generation and metallurgical plants.
  • Industrial Furnaces, Kilns and Heat Treatment: For temperature measurement and extension wiring on heat-treating furnaces, ceramic kilns, ovens and thermal processing lines.
  • Autoclaves, Cryogenic Chambers and Test Rigs: For precision thermal profiling in aerospace autoclaves, environmental test chambers, semiconductor tools and laboratory instrumentation.

Standards & Compliance

  • Standard: IEC 60584-3 / ASTM E230
  • RoHS: Compliant
  • REACH: Compliant

TC-GGPA — Fiberglass Core, NPC Shielded & PFA Jacketed 260°C Wire

CASMO Part No.Total CoresConductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Nom. Core O.D. (mm)Nominal Inner Braid Wall (mm)Nom. Shield Thickness (mm)Nom. Jkt. Thickness (mm)Nom. Overall Width (mm)Overall Width Tolerance ± (mm)Nom. Overall Thickness (mm)Overall Thickness Tolerance ± (mm)
710222C26-KX-XX22670.160.480.20.90.20.20.53.60.22.70.2
710222C24-KX-XX22470.20.60.21.00.20.20.53.80.22.80.2
710222C22-KX-XX22270.2540.760.21.20.20.20.54.20.23.00.2
710222C20-KX-XX22070.320.960.21.40.20.20.54.60.23.20.2
710222C18-KX-XX21870.391.170.21.60.20.20.55.00.23.40.2
710222C16-KX-XX216190.31.50.21.90.20.20.55.60.23.70.2
710222C14-KX-XX214190.371.850.22.30.20.20.56.40.24.10.2

* "-KX-" = Type KX extension-grade alloy pair (NiCr / NiAl, standard; EMF calibrated up to +200°C). Substitute "-JX-", "-EX-", "-NX-", "-RX-", "-SX-" (EMF calibrated ≤ +200°C), "-TX-" (EMF calibrated ≤ +100°C), or thermocouple-grade "-K-", "-J-", "-T-", "-E-", "-N-" for sensing-junction or > +200°C service (Type T wire-gauge limit: +200°C for 26–20 AWG, +260°C for 16–14 AWG). † "-XX" = color-code suffix: IEC 60584-3 color code supplied as standard (e.g., GN for Type K/KX); ASTM E230 color code available upon request (see Color Code Chart below).

  • "-KX-" = Type KX extension-grade alloy pair (NiCr / NiAl, standard; EMF calibrated up to +200°C). Substitute "-JX-", "-EX-", "-NX-", "-RX-", "-SX-" (EMF calibrated ≤ +200°C), "-TX-" (EMF calibrated ≤ +100°C), or thermocouple-grade "-K-", "-J-", "-T-", "-E-", "-N-" for sensing-junction or > +200°C service (Type T wire-gauge limit: +200°C for 26–20 AWG, +260°C for 16–14 AWG).
  • "-XX" = color-code suffix: IEC 60584-3 color code supplied as standard (e.g., GN for Type K/KX); ASTM E230 color code available upon request (see Color Code Chart below).

Color Code Chart

  • +Green / -White (Jkt: Green)
  • +Black / -White (Jkt: Black)
  • +Brown / -White (Jkt: Brown; TX ≤100°C)
  • +Violet / -White (Jkt: Violet)
  • +Pink / -White (Jkt: Pink)
  • +Orange / -White (Jkt: Orange; ≤100°C)
  • +Yellow / -Red (TC: Brown / Ext: Yellow)
  • +White / -Red (TC: Brown / Ext: Black)
  • +Blue / -Red (TC: Brown / Ext: Blue; TX ≤100°C)
  • +Purple / -Red (TC: Brown / Ext: Purple)
  • +Orange / -Red (TC: Brown / Ext: Orange)
  • +Black / -Red (Ext: Green; ≤200°C)