TC-KK

TC-KK is a CASMO thermocouple wire for Thermocouple Wire. Polyimide / FEP heat-seal film tape insulated, -190°C to +260°C. Ultra-thin, low-outgassing 2-core parallel flat thermocouple wire with wrapped polyimide / FEP heat-seal film tape core insulation and overall polyimide / FEP heat-seal film …

Ultra-thin, low-outgassing 2-core parallel flat thermocouple wire with wrapped polyimide / FEP heat-seal film tape core insulation and overall polyimide / FEP heat-seal film tape jacket (-190°C to +260°C).

Key Ratings

  • TC-KK: · Temperature -190°C to +260°C

Construction

Conductor
Thermocouple Alloy (Type K / J / T / E / N) or Extension / Compensating Alloy (Type KX / JX / TX / EX / NX / RX / SX) · Stranded
Core Insulation
Wrapped · Polyimide / FEP heat-seal film tape
Cabling
Parallel · Duplex parallel flat core pair
Core Identification
Color-coded per IEC 60584-3 (Type K/KX: +Green / -White) or ASTM E230 on request
Jacket
Wrapped jacket · Polyimide / FEP heat-seal film tape

Characteristics

  • Heat-Seal Laminate Limit: FEP fluoropolymer heat-seal adhesive layer limits continuous operating temperature to +260°C (contains fluoropolymer; not PFAS-free).
  • EMF Calibration Span: Insulation rated to +260°C continuous; extension-grade alloys (-KX-/-JX-/-EX-/-NX-/-RX-/-SX-) are EMF-calibrated from 0°C to +200°C (-TX- up to +100°C). Specify thermocouple-grade alloys (-K-/-J-/-E-/-N-/-T-) above +200°C or below 0°C (sub-zero / cryogenic service).
  • Signal Circuit Duty: Low-voltage thermoelectric millivolt EMF measurement and extension signal circuits only (not rated for mains power distribution).
  • Calibrated EMF Accuracy: Matched thermoelectric conductor pairs maintain stable electromotive force characteristics across the rated temperature span.
  • Ultra-Thin Compact Profile: Compact parallel duplex geometry reduces bundle cross-section for tight sensor feedthroughs, vacuum chambers and test fixtures.
  • Low-Temperature Flexibility: Maintains flexibility at low temperatures, facilitating cable routing and handling in cold environments.
  • High-Temperature Thermal Stability: Heat-resistant insulation and jacketing resist thermal aging, embrittlement and cut-through in elevated-temperature zones.

Applications

  • Autoclaves, Cryogenic Chambers and Test Rigs: For precision thermal profiling in aerospace autoclaves, environmental test chambers, semiconductor tools and laboratory instrumentation.
  • Sensors and Instrumentation: For connections between sensors, measuring instruments and associated control equipment.
  • Process Temperature Sensing and Pyrometry: For connecting thermocouple probes and cold-junction transmitters across chemical, petrochemical, power-generation and metallurgical plants.

Standards & Compliance

  • Standard: IEC 60584-3 / ASTM E230
  • RoHS: Compliant
  • REACH: Compliant

TC-KK — Wrapped Polyimide / FEP Film 260°C Duplex Wire

CASMO Part No.Total CoresConductor Size (AWG)No. Of StrandsNom. Strand Dia. (mm)Nom. Conductor Dia. (mm)Nom. Ins. Thickness (mm)Nom. Core O.D. (mm)Nom. Jkt. Thickness (mm)Nom. Overall Width (mm)Overall Width Tolerance ± (mm)Nom. Overall Thickness (mm)Overall Thickness Tolerance ± (mm)
710162C26-KX-XX22670.160.480.10.70.11.60.20.90.2
710162C24-KX-XX22470.20.60.10.80.11.80.21.00.2
710162C22-KX-XX22270.2540.760.11.00.12.20.21.20.2
710162C20-KX-XX22070.320.960.11.20.12.60.21.40.2
710162C18-KX-XX21870.391.170.11.40.13.00.21.60.2
710162C16-KX-XX216190.31.50.11.70.13.60.21.90.2
710162C14-KX-XX214190.371.850.12.10.14.40.22.30.2

* "-KX-" = Type KX extension-grade alloy pair (NiCr / NiAl, standard; EMF calibrated up to +200°C). Substitute "-JX-", "-EX-", "-NX-", "-RX-", "-SX-" (EMF calibrated ≤ +200°C), "-TX-" (EMF calibrated ≤ +100°C), or thermocouple-grade "-K-", "-J-", "-T-", "-E-", "-N-" for sensing-junction or > +200°C service (Type T wire-gauge limit: +200°C for 26–20 AWG, +260°C for 16–14 AWG). † "-XX" = color-code suffix: IEC 60584-3 color code supplied as standard (e.g., GN for Type K/KX); ASTM E230 color code available upon request (see Color Code Chart below).

  • "-KX-" = Type KX extension-grade alloy pair (NiCr / NiAl, standard; EMF calibrated up to +200°C). Substitute "-JX-", "-EX-", "-NX-", "-RX-", "-SX-" (EMF calibrated ≤ +200°C), "-TX-" (EMF calibrated ≤ +100°C), or thermocouple-grade "-K-", "-J-", "-T-", "-E-", "-N-" for sensing-junction or > +200°C service (Type T wire-gauge limit: +200°C for 26–20 AWG, +260°C for 16–14 AWG).
  • "-XX" = color-code suffix: IEC 60584-3 color code supplied as standard (e.g., GN for Type K/KX); ASTM E230 color code available upon request (see Color Code Chart below).

Color Code Chart

  • +Green / -White (Jkt: Green)
  • +Black / -White (Jkt: Black)
  • +Brown / -White (Jkt: Brown; TX ≤100°C)
  • +Violet / -White (Jkt: Violet)
  • +Pink / -White (Jkt: Pink)
  • +Orange / -White (Jkt: Orange; ≤100°C)
  • +Yellow / -Red (TC: Brown / Ext: Yellow)
  • +White / -Red (TC: Brown / Ext: Black)
  • +Blue / -Red (TC: Brown / Ext: Blue; TX ≤100°C)
  • +Purple / -Red (TC: Brown / Ext: Purple)
  • +Orange / -Red (TC: Brown / Ext: Orange)
  • +Black / -Red (Ext: Green; ≤200°C)