BS 3G 210 — British Aerospace PTFE Equipment Wire

Specifies extruded and wrapped PTFE-insulated defence and avionics wires across three wall-thickness voltage grades — Type A (300V), Type B (600V) and Type C (1000V) — up to +260°C.

Standard · British Standards Institution (BSI)

What is BS 3G 210?

BS 3G 210 is the British Standard for extruded and lapped polytetrafluoroethylene (PTFE) single-core equipment wires widely specified across UK and European avionics, defence instrumentation and high-reliability electronics. Operating from −75°C to +190°C with silver-plated copper or +260°C with nickel-plated copper, BS 3G 210 delivers exceptional aviation-fuel immunity, dielectric stability and non-flammability.

The specification classifies wires strictly by PTFE wall thickness and RMS voltage rating: lightweight Type A (300V), standard-wall Type B (600V) and heavy-wall Type C (1000V) for exposed or mechanically demanding installations.

Under BS 3G 210, conductor plating is explicitly encoded in the type prefix: Types A, B and C use silver-plated copper conductors rated −75°C to +190°C continuous (offering ~100% IACS conductivity and effortless soldering), whereas Types NA, NB and NC use nickel-plated copper conductors extending continuous thermal endurance to +260°C for engine-bay, sensor and high-heat defence wiring.

Although functionally analogous to commercial NEMA HP3 (Types ET, E and EE) and SAE AS 22759/11–/12 PTFE wires, BS 3G 210 defines metric-strand conductor builds (such as 7/0.20 mm and 19/0.25 mm) and distinct dimensional tolerances. For extruded PTFE constructions, verify outer diameters within CASMO's 6.5 mm extruded PTFE O.D. capability and confirm connector crimp tooling prior to cross-standard substitution.

Key Technical Requirements

ParameterRequirementNotes
Voltage gradesType A (300V) · Type B (600V) · Type C (1000V)Distinguished by PTFE wall thickness
ConductorsSilver-plated (190°C) · Nickel-plated (260°C)IEC/BS fine stranding
InsulationExtruded or lapped PTFEInert to aviation fuels & lubricants
Temperature−75°C to +190°C / +260°CPlating dependent
Plating codesTypes A / B / C (SPC) · Types NA / NB / NC (NPC)N prefix identifies 260°C nickel-plated copper
Electrical & Fireεr ~2.0–2.1 · Non-flammable PTFEResists solder iron heat & aviation fluids

BS 3G 210 Products

Insulation Materials in This Standard

Frequently Asked Questions

How do BS 3G 210 Type A, Type B and Type C differ?
Type A is thin-wall 300V RMS for compact harnesses, Type B is standard-wall 600V RMS for general equipment wiring, and Type C is heavy-wall 1000V RMS for higher electrical and mechanical stress.
Can BS 3G 210 wires operate up to +260°C?
Yes — silver-plated copper constructions are rated to +190°C continuous, while nickel-plated copper extends continuous operation to +260°C.
What do the NA, NB and NC designations mean in BS 3G 210?
The N prefix designates nickel-plated copper conductors rated to +260°C continuous across the same three PTFE voltage/wall classes — NA (300V thin-wall), NB (600V standard-wall) and NC (1000V heavy-wall) — compared with silver-plated copper Types A, B and C rated to +190°C.
Can NEMA HP3 (Type ET, E, EE) replace BS 3G 210 Type A, B or C wire directly?
Not without drawing and crimp review. While both specify extruded PTFE across comparable voltage tiers, NEMA HP3 uses AWG stranding and a 250V thin-wall Type ET (200°C SPC), whereas BS 3G 210 uses metric strand gauges, a 300V Type A rating and a conservative 190°C SPC ceiling.