Custom Engineering · 12 min read · Reviewed by CASMO Cable Engineering Team · Updated 2026-11-26
Direct Engineering Answer
Every NEMA WC 27500 / SAE AS27500 (formerly MIL-DTL-27500) part number encodes a modular shielded and jacketed multiconductor cable across seven sequential fields: M27500 + [Core ID & Shield Coverage Modifier] + [AWG Size] + [2-Letter Basic Wire Symbol] + [Number of Conductors] + [Shield Style/Material Letter] + [2-Digit Outer Jacket Code]. For example, M27500-22SB2T23 specifies ≥85% braid coverage with preferred striped white core identification (-), 22 AWG conductors (22), SAE AS22759/32 single-wall tinned-copper XL-ETFE component wires (SB), 2 twisted cores (2), a round tinned-copper braid shield (T), and a white radiation cross-linked modified ETFE outer jacket (23) — corresponding functionally in commercial, motorsport, and UAV service to Raychem 55A1121-22 and CASMO CASRAD XE 150MC (522012C22-TS-WH). Before substituting any commercial shielded cable for an M27500 callout, engineers must verify three items: system temperature ceiling (governed by the lowest-rated layer among core, shield, and jacket), internal core color code (M27500 '-' white/stripe vs. Method 'A' solid White/Blue/Orange/Green vs. CASMO's standard NEMA solid sequence #1 Black, #2 White, #3 Green, #4 Red), and QPL vs. non-QPL contract scope.
Key Engineering Takeaways
- M27500 is a modular assembly specification rather than a standalone insulation chemistry: Table I selects the inner hook-up wire standard (such as SB = AS22759/32, SD = AS22759/34, SR = AS22759/44, SP = AS22759/43, ML = AS81044/12), Table IA selects the EMI shield (T = tinned copper, S = silver-plated copper, N = nickel-plated copper, G = flat SPC), and Table IB selects the outer jacket (23 = white XL-ETFE, 08 = white XL-PVDF).
- Watch jacket code 14 vs. 08 vs. 23: in NEMA WC 27500 Table IB, code 23 is cross-linked white XL-ETFE (200°C) and code 08 is cross-linked white XL-PVDF (150°C), whereas code 14 is unirradiated white ETFE (150°C).
- Cable temperature rating equals the minimum of its three metallic and polymer layers: pairing a 200°C jacket (code 23) over 150°C tinned-copper cores (SB or SD) and a 150°C tinned-copper braid (T) yields a 150°C finished cable.
- Always check Position 2 core identification before pinning connectors: a dash (-) specifies white cores with colored helical stripes (#1 White, #2 White/Blue, #3 White/Orange, #4 White/Green), whereas CASMO CASRAD MC stock reels use high-contrast standard NEMA solid colors (#1 Black, #2 White, #3 Green, #4 Red) inside a white (-WH) outer jacket.
1. The 7-Position Anatomy of an M27500 / NEMA WC 27500 Part Number
Translating legacy MIL-C-27500, MIL-DTL-27500, SAE AS27500, and NEMA WC 27500 callouts
Across avionics CAN/RS-485 data buses, LVDT/RVDT actuator sensors, flight-control strain gauges, and motorsport power-box interconnects, engineers frequently inherit bill-of-materials callouts beginning with M27500 (such as M27500-22SB2T23, M27500-20SP3S23, or M27500-22ML4T08). Originally issued as military specification MIL-C-27500 (later MIL-DTL-27500) and maintained today across SAE AS27500 for aerospace QPL programs and NEMA WC 27500 for commercial/industrial cables, the standard acts as a modular 'recipe builder' that twists 1 to 15+ qualified primary hook-up wires into a concentric bundle, applies single or double metallic braid shielding, and extrudes or wraps an environmental outer jacket.
Once you split the alphanumeric string into its seven fixed positions, every electrical, thermal, and mechanical attribute of the cable can be read without opening a catalog:

- Position 1 — Base Specification Prefix (M27500): Identifies the modular shielded/jacketed aerospace cable architecture.
- Position 2 — Identification Method & Shield Coverage Modifier (-, A, B, C, D, E...): A hyphen (-) denotes ≥85% optical braid coverage with Table III-A Preferred Method core color coding (white component wires marked with helical colored stripes). Letter 'A' denotes ≥85% coverage with Optional Method A solid-colored component wires per Table III-A, while 'B' invokes Optional Method B (AWG-size-coded solid wires per Table III-C with circumferential color bands per Table III-D); letters 'C', 'D', and 'E' upgrade those exact three identification methods (-, A, B) to tighter ≥90% optical shield coverage (while F–J invoke alternative Table III-B color sequences at 85% [F, G] or 90% [H, J] coverage).
- Position 3 — Conductor Size (AWG): Two digits (or single digit for heavy gauges) specifying the AWG size of each component conductor — most commonly 26, 24, 22, 20, 18, 16, 14, or 12 AWG.
- Position 4 — Two-Letter Basic Wire Code (Table I): Defines the exact SAE AS22759, SAE AS81044, or NEMA HP slash sheet used for the inner insulated cores (e.g., SB, SD, SR, SP, ML, MH, TE, TG).
- Position 5 — Number of Conductors (1 to 15+): Total count of helically cabled primary cores inside the shield (2 = twisted pair, 3 = twisted triad, 4 = twisted quad).
- Position 6 — Single-Letter Shield Code (Table IA): Defines shield wire metallurgy, strand geometry (round vs. flat), and single vs. double shield construction (e.g., T = single round tinned copper braid, S = single round silver-coated copper braid, N = single round nickel-coated copper braid, G = single flat silver-coated copper braid, V / W / Y = double round TPC / SPC / NPC braids, U = unshielded).
- Position 7 — Two-Digit Outer Jacket Code (Table IB): Defines outer jacket polymer chemistry, single vs. double jacket, and standard white/clear appearance (e.g., 23 = single white cross-linked XL-ETFE, 08 = single white cross-linked XL-PVDF, 06 = white PTFE, 00 = no jacket).
2. Reference Lookup Tables: Decoding Core Wires (Table I), Shields (Table IA) & Jackets (Table IB)
Avoiding the three most common code mix-ups: SR vs. SP, Jacket 08 vs. 14 vs. 23, and Shield temperature caps
While NEMA WC 27500 / SAE AS27500 contains dozens of historical PTFE, polyimide, and silicone symbols, modern radiation cross-linked aerospace, UAV, and motorsport harnesses concentrate heavily around six Table I basic wire codes, three Table IA round-wire braid codes, and four Table IB fluoropolymer jacket codes.
Pay special attention to two frequent lookup errors when translating legacy drawings: first, in Table IB outer jackets, code 08 designates radiation cross-linked white PVDF (Kynar, 150°C) and code 23 designates radiation cross-linked white modified ETFE (200°C), whereas code 14 designates unirradiated melt-extruded white ETFE (150°C) and code 24 designates composite PTFE/polyimide/FEP tape wrap. Second, never assume a 200°C jacket code (23) makes the cable rated 200°C on its own: in M27500-22SB2T23, both the SB inner core (AS22759/32 tinned copper, 150°C) and the T shield (tinned copper braid, 150°C) cap the finished cable assembly at −65°C to +150°C. Achieving a true 200°C XL-ETFE cable requires pairing silver-plated cores (SR or SP) with a silver-plated braid (S) and jacket 23 — as in M27500-22SR2S23 or M27500-22SP2S23.
| Code Group & Symbol | Underlying Standard / Material | Wall / Construction Detail | Element Temp Ceiling |
|---|---|---|---|
| Table I Core · SB | SAE AS22759/32 (55A0111) | Single-wall XL-ETFE · Tin-plated copper | 150°C (600V) |
| Table I Core · SD | SAE AS22759/34 (55A0811) | Dual-wall XL-ETFE · Tin-plated copper | 150°C (600V) |
| Table I Core · SR | SAE AS22759/44 (55A0112) | Single-wall XL-ETFE · Silver-plated copper | 200°C (600V) |
| Table I Core · SP | SAE AS22759/43 (55A0812) | Dual-wall XL-ETFE · Silver-plated copper | 200°C (600V) |
| Table I Core · ML / MH | SAE AS81044/12 (ML) · AS81044/9 (MH) | Dual-wall XL-Polyalkene / PVDF · Tinned copper | 150°C (600V) |
| Table IA Shield · T / S / N / G | Cu Braid (≥85% default coverage) | Round: T (TPC), S (SPC), N (NPC) · Flat: G (SPC) | 150°C (T) · 200°C (S, G) · 260°C (N) |
| Table IB Jacket · 23 | Irradiation Cross-Linked Modified ETFE | Extruded white XL-ETFE single jacket | 200°C |
| Table IB Jacket · 08 | Irradiation Cross-Linked PVDF | Extruded white XL-PVDF single jacket | 150°C |
| Table IB Jacket · 14 / 06 | Unirradiated ETFE (14) · PTFE (06) | Extruded white ETFE (14) · Taped/ext. PTFE (06) | 150°C (14) · 260°C (06) |
3. Cross-Referencing M27500 & Raychem 55A / 44A SCDs to CASMO CASRAD MC Series
Direct dimensional alignment across 2-core, 3-core, and 4-core shielded & white-jacketed (-WH) cables
On commercial aerospace, UAV, defense vehicle, and motorsport drawings, shielded multiconductor cables are called out either via M27500 nomenclature or via TE Connectivity / Raychem Specification Control Drawing (SCD) numbers: 55A1121 (2C), 55A1131 (3C), and 55A1141 (4C) for 150°C tinned-copper XL-ETFE; 55A1122 / 1132 / 1142 for 200°C silver-plated XL-ETFE; 44A1121 / 1131 / 1141 for 600V 150°C polyalkene/PVDF; and 44A1221 / 1231 / 1241 for 1000V 150°C polyalkene/PVDF.
CASMO's four CASRAD shielded multicore series — CASRAD XE 150MC (Series 52201), CASRAD XE 200MC (Series 52202), CASRAD XP 150MC (Series 53201), and CASRAD XP 150MC 1KV (Series 53202) — align directly with those SCD dimensional and weight envelopes using ≥85% optical coverage round metallic wire braids (preserving authentic see-through open-weave flexibility and easy comb-out pigtail or 360-degree backshell termination) beneath a UV-laser markable satin white (-WH) cross-linked outer jacket:

| CASMO Series (20 AWG 2C Sample PN) | M27500 Functional Counterpart | Raychem SCD Reference | Rating & Braid | CASMO 20 AWG 2C Nom. / Max. O.D. & Max. Weight |
|---|---|---|---|---|
| CASRAD XE 150MC (522012C20-TS-WH) | M27500-20SB2T23 (or SD2T23) | 55A1121 / 55PC1121 (2C) · 1131 (3C) · 1141 (4C) | 150°C · 600V · ≥85% TPC | 3.43 mm nom. / 3.58 mm max · 24.1 kg/km |
| CASRAD XE 200MC (522022C20-SS-WH) | M27500-20SR2S23 (or SP2S23) | 55A1122 / 55PC1122 (2C) · 1132 (3C) · 1142 (4C) | 200°C · 600V · ≥85% SPC | 3.38 mm nom. / 3.56 mm max · 24.0 kg/km |
| CASRAD XP 150MC (532012C20-TS-WH) | M27500-20ML2T08 | 44A1121 (2C) · 1131 (3C) · 1141 (4C) | 150°C · 600V · ≥85% TPC | 3.76 mm nom. / 3.89 mm max · 28.0 kg/km |
| CASRAD XP 150MC 1KV (532022C20-TS-WH) | 1000V Spec 44 Extension (24–12 AWG) | 44A1221 (2C) · 1231 (3C) · 1241 (4C) | 150°C · 1000V · ≥85% TPC | 3.96 mm nom. / 4.11 mm max · 30.8 kg/km |
4. Three Pre-Substitution Engineering Checks: Core Colors, Braid Termination & QPL Scope
Preventing pin-transposition errors and backshell clamping mismatches during harness build
Before releasing an Engineering Change Notice (ECN) substituting a commercial shielded aerospace/motorsport cable for an M27500 or 55A/44A print callout, run through three practical harness-engineering checks:
First, reconcile internal core color coding on assembly work instructions. Under NEMA WC 27500 / MIL-DTL-27500 Table III-A, a dash (-) in Position 2 specifies white cores with helical color stripes: Core #1 is solid White, Core #2 is White with a Blue stripe, Core #3 is White with an Orange stripe, and Core #4 is White with a Green stripe (while Optional Method 'A' uses solid White, Blue, Orange, Green, and Raychem 55A/44A SCDs commonly append MIL-STD-681 color suffixes such as -9/96 or -0/9). CASMO CASRAD MC stock series use high-contrast standard NEMA solid colors (#1 Black, #2 White, #3 Green, #4 Red) under a standard white (-WH) outer jacket so dark-cockpit or pit-lane technicians can distinguish cores instantly without a magnifier — while custom MIL-STD-681 striped or Method A solid sequences (and -BK black outer jackets) are produced on custom runs.
Second, verify EMI shield termination hardware. All four CASRAD MC series use round-wire metallic braids at ≥85% optical coverage rather than foil-only tape, making them compatible with solder-sleeve shield terminators (such as SAE AS83519 / Raychem SolderSleeve devices — using low-temperature BiSn solder sleeves on 150°C XP polyalkene/PVDF cables or standard SnPb/SAC sleeves on 200°C XL-ETFE cables), 360-degree Constant-Force / Band-It EMI backshell clamps, and combed-out ground pigtails.
Third, confirm qualification paperwork: SAE AS27500 QPL cables are mandatory when a defense or commercial transport airworthiness contract explicitly requires QPL-listed lot release, whereas NEMA WC 27500 / CASRAD MC cables provide cost-effective, dimensionally aligned non-QPL performance for motorsport, commercial UAVs, ground test rigs, industrial automation, and marine electronics.
Frequently Asked Questions
- What does M27500-22SB2T23 mean in plain engineering terms?
- It specifies a 2-conductor twisted, shielded, and jacketed cable built with 22 AWG SAE AS22759/32 single-wall tinned-copper XL-ETFE wires (SB) using preferred white/striped core identification and ≥85% braid coverage (-), a round tinned-copper EMI braid shield (T), and a single extruded white cross-linked XL-ETFE outer jacket (23), rated −65°C to +150°C and 600V AC.
- What is the difference between M27500 jacket code 23, jacket code 14, and jacket code 08?
- In NEMA WC 27500 / MIL-DTL-27500 Table IB, code 23 is radiation cross-linked white modified ETFE rated up to 200°C; code 08 is radiation cross-linked white PVDF (Kynar) rated up to 150°C; and code 14 is unirradiated extruded white ETFE rated up to 150°C. Specifying code 23 or 08 ensures the outer jacket is electron-beam cross-linked against solder-iron melt-back.
- Why is M27500-20SB2T23 rated 150°C even though jacket code 23 is rated 200°C?
- Finished M27500 cable temperature rating is governed by the lowest-rated component in the stackup. Because both the SB core wire (AS22759/32 tinned copper) and the T braid shield (tinned copper) are capped at 150°C, the complete cable is rated 150°C. Upgrading to 200°C requires silver-plated cores (SR or SP) and a silver-plated braid (S), such as M27500-20SR2S23 (CASRAD XE 200MC).
- How do core colors differ between M27500 '-' cables and CASMO CASRAD MC standard cables?
- Military M27500 '-' Preferred Method uses white cores with helical stripes (#1 White, #2 White/Blue, #3 White/Orange, #4 White/Green), while Method 'A' uses solid White, Blue, Orange, Green. CASMO CASRAD MC standard stock cables use standard NEMA solid colors (#1 Black, #2 White, #3 Green, #4 Red) inside a white (-WH) outer jacket; update harness pinout sheets accordingly or request custom MIL-striped cores.
- What does the -WH suffix mean on CASMO part numbers like 522012C20-TS-WH?
- In CASMO's Series 522 (CASRAD XE MC) and Series 532 (CASRAD XP MC) part numbers, -WH designates the standard UV-laser markable White outer jacket (matching aerospace jacket codes 23 and 08). Matte Black (-BK) and custom outer jacket colors are available on request.
- When should I choose CASRAD XP 150MC 1KV (53202) over standard 600V M27500 cables?
- Standard M27500 cables built with AS22759 (/32, /34, /43, /44) or AS81044 (/12) cores are rated 600V AC. Choose CASRAD XP 150MC 1KV (aligned with Raychem 44A1221 / 1231 / 1241 across 24–12 AWG) when inverter drives, 800V–1000V auxiliary buses, rail traction, or industrial cabinets require a full 1000V AC / 3,000V dielectric-withstand shielded multiconductor cable.
Regulatory & Engineering References
- NEMA — NEMA WC 27500 (Standard for Aerospace and Industrial Electrical Cable — Tables I, IA, IB, II, and IIIA–IIID).
- SAE International — SAE AS27500 (Electrical Cable, Aerospace and Industrial, Shielded and Jacketed, superseding MIL-DTL-27500).
- SAE International — SAE AS22759 (/32, /34, /43, /44) and SAE AS81044 (/9, /11, /12) Component Hook-Up Wire Specifications.
- SAE International — SAE AS83519 (Shield Termination, Solder Style, Insulated, Heat-Shrinkable, Environment Resistant).
- U.S. DoD / UL — MIL-STD-681 (Identification Coding and Application of Hookup and Lead Wire) and UL 62 / NEMA Standard Multicore Conductor Color Coding.