Railway & Rolling-Stock Cables
Halogen-free electron-beam cross-linked railway rolling-stock power and control cables engineered to EN 50264-3-1 and EN 45545-2 (HL1–HL3, R15 / R16), including 3GKW FLEX (0.6/1 kV) and 4GKW-AX PLUS FLEX (1.8/3 kV).
Electron-beam cross-linked rolling-stock cables for rail vehicles
Passenger trains, metro cars, light-rail vehicles and locomotives pack dense control cabinets, auxiliary distribution harnesses and traction feeders into tight conduits exposed to continuous vibration, mineral oil and diesel splash, ozone, and thermal cycling from −40°C to +120°C (+250°C short-circuit for 5 s). Electron-beam cross-linked halogen-free polyolefin (EN 50264-1 EI 109 / EI 110 Category M) converts the insulation into an infusible thermoset network that will not melt or drip under thermal overload while achieving the reduced wall thickness and lower harness weight mandated by EN 50264-3-1.
CASMO supplies two complementary EN 50264-3-1 voltage tiers tailored to rolling-stock architectures. 3GKW FLEX (0.6/1 kV AC, 0.5 mm² to 400 mm²) uses a compact single-layer black cross-linked halogen-free XLPO wall over fine-stranded tinned copper for onboard control panels, switchgear, lighting, door drives and auxiliary circuits. For higher-voltage traction duty, 4GKW-AX PLUS FLEX (1.8/3 kV AC, Um 3.6 kV, 1 mm² to 400 mm²) combines extra-flexible tinned copper stranding with a dual-layer contrasting white-inner and black-outer XLPO wall that provides immediate visual indication of mechanical scrape or wear in traction converters, inverters, auxiliary power units and bogie jumpers.
Fire safety is integral to every railway cable design. Both series are engineered for EN 45545-2 Hazard Levels HL1 through HL3 across interior (R15) and exterior (R16) cable requirement sets — combining vertical single-wire and bunched flame-spread control (IEC 60332-1-2, IEC 60332-3-24, IEC 60332-3-25 and EN 50305), low smoke density (IEC 61034-2 / EN 61034-2), and zero-halogen low acid-gas and low-toxicity performance (IEC 60754-1, IEC 60754-2 and EN 50305) to protect passengers and tunnel infrastructure.
Railway & Rolling Stock Products
- 3GKW FLEX — EN 50264-3-1 · Halogen-Free XLPO · -40°C to +120°C · 600/1000V
- 4GKW-AX PLUS FLEX — EN 50264-3-1 · Halogen-Free XLPO / Halogen-Free XLPO · -40°C to +120°C · 1800/3000V
Related Standards, Materials & Applications
Frequently Asked Questions
- How do 3GKW FLEX (0.6/1 kV) and 4GKW-AX PLUS FLEX (1.8/3 kV) differ in construction and application?
- 3GKW FLEX (600/1000V AC, 3.5 kV AC test voltage, 0.5–400 mm²) features a space-saving single-layer black cross-linked XLPO wall for protected cabinet wiring, lighting, signaling and auxiliary circuits. 4GKW-AX PLUS FLEX (1800/3000V AC, 6.5 kV AC test voltage, 1–400 mm²) uses extra-flexible stranding and a dual-layer white-inner / black-outer XLPO wall for visual wear inspection in traction converters, inverters and inter-car or bogie feeders.
- What do EN 45545-2 Requirement Sets R15 / R16 and Hazard Levels HL1–HL3 mean for railway cables?
- Under EN 45545-2, electrical cables on rail vehicles are evaluated specifically against Requirement Set R15 (interior cables) and R16 (exterior and underframe cables) across Hazard Levels HL1, HL2 and HL3 — where HL3 represents the most stringent fire-safety tier for underground metro, tunnel and sleeper vehicles.
- Why does EN 50264-3-1 specify electron-beam cross-linked halogen-free insulation instead of PVC or thermoplastic LSZH?
- Thermoplastic PVC releases dense smoke and corrosive hydrochloric acid gas in a fire, while uncross-linked thermoplastic LSZH softens under overload heat. Electron-beam cross-linked EI 109 / EI 110 compounds form a thermoset structure that withstands +120°C operating temperatures, +250°C short-circuit transients (5 s), soldering heat, mineral oils and diesel fuel in a thin, lightweight wall.
- Why are fine-stranded tinned copper conductors used in rolling-stock cables?
- EN 60228 Class 5 and extra-flexible fine-stranded tinned copper conductors resist vibration fatigue on rail carbodies and bogies, permit tight bending radii inside high-density switchgear cabinets, and protect individual copper filaments against oxidation at crimp lugs and terminal blocks.
- How are EN 50264 AC voltage ratings U0/U (600/1000V and 1800/3000V) and DC operating limits defined?
- U0 is the nominal RMS AC voltage between conductor and earth, while U is the nominal RMS AC voltage between phases. On 3GKW FLEX (U0/U = 600/1000V AC), maximum AC system voltage U0m/Um is 720/1200V AC and maximum permitted DC voltage V0/Vm is 900/1500V DC; on 4GKW-AX PLUS FLEX (U0/U = 1800/3000V AC), U0m/Um is 2160/3600V AC and V0/Vm is 2700/4500V DC.
Engineering Guides
- XLPE Cross-Linking Methods Compared: Electron-Beam Irradiation vs. Chemical Peroxide (CCV) vs. Silane (Sioplas & Monosil) — How electron-beam irradiation, chemical peroxide CCV curing, and silane moisture cross-linking convert polyethylene into thermoset XLPE — comparing thermal rating, wall-thickness limits, scorch risk, hot-set QC testing, and XLPE/XLPO/XLPVC/XL-ETFE wire standards.